ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Wiley-Blackwell  (848)
  • Cambridge University Press  (229)
  • 1970-1974  (1,027)
  • 1950-1954  (50)
  • 1973  (558)
  • 1970  (469)
  • 1950  (50)
Collection
Years
  • 1970-1974  (1,027)
  • 1950-1954  (50)
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 17 (1973), S. 269-282 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The development of gel permeation chromatography (GPC) has provided a convenient tool for the rapid determination of molecular weight distribution. The question has arisen as to the suitability of the method for specification purposes. The present work, suggested by the Naval Air Systems Command, represents an attempt to assess the precision of the method through a series of tests carried out by a number of laboratories using identical procedures on the same samples. Ten laboratories agreed to take part. Naval Ordnance Station, Indian Head, worked out standard conditions for operation of the chromatograph, for calibration of the columns, and for analysis of the GPC curves. Two samples of polystyrene were used by the various organizations for calibration of their instruments. Number-average molecular weight, heterogeneity index, and cumulative molecular weight distribution curves were determined on four samples of carboxyl-terminated polybutadiene (CTPB) and two samples of hydroxyl-terminated polybutadiene (HTPB), all unidentified except by letter code. All laboratories used identical directions for setting up CTPB and HTPB calibration curves which were based on curves determined from vapor-pressure osmometer molecular weights and GPC count numbers of fractionated material. Variation among the different laboratories was 0.15 in heterogeneity index, and a maximum of 1200 in molecular weight provided one aberrant set of values was eliminated. The six samples had heterogeneity indices from 1.15 to 1.54, while molecular weight varied from approximately 3000 to 6000. The average coefficient of variation of the molecular weight values was 6.2 ± 0.7%, which is quite acceptable. Variation in heterogeneity index was too great for specification purposes when considered among the different laboratories, but may be sufficiently good when measured by any one laboratory.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 15 (1973), S. 1131-1145 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Several techniques for investigating the multiplicity and stability of open isothermal enzymatic reactors are discussed and some of the pitfalls in previous thinking pointed out. The example which is used to illustrate these methods exhibits several interesting features. Among these is the existence of a stable oscillatory state which surrounds a unique steady state which is asymptotically stable to certain finite disturbances.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Gram-sized quantities of purified arginine, formylmethionine, glutamic acid, and phenylalanine-2 tRNAs have been prepared from pools of E. coli K-12 MO7 mixed tRNAs by reversed-phase chromatography after preliminary fractionation on DEAE-cellulose. Purified formylmethionine tRNA and partially purified arginine tRNA and glutamie acid tRNA were obtained from large-scale RPC-3 runs (4 × 36 in. column). The arginine tRNA was further purified by rechromatography on RPC-4 columns, and the gluatmic acid tRNA by rechromatography on an RPC-3 column. Two phenylalanine tRNAs were resolved on large-scale (2 × 96 in. column) RPC-3 runs; only the second phenylalanine tRNA reached a satisfactory degree of activity. About 0.88 g of arginine tRNA, 70% activity; 3.32 g of formylmethionine tRNA, 97% activity; 0.80 g of glutamic acid tRNA, 83% activity and O.92 g of phenylalanine-2 tRNA, 78% activity, were produced. The processing steps employed are reliable and reproducible and the procedure is amenable to routine production of these tRNAs.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Die Makromolekulare Chemie 169 (1973), S. 177-189 
    ISSN: 0025-116X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Die elektroinitiierte Polymerisation von N-Vinylcarbazol (VCZ) wurde in Aceton bei 25°C mit Zinkbromid als Katalysator unter Verwendung von Platinelektroden eingehend untersucht. Die Polymerisationsgeschwindigkeit erwies sich als direkt abhängig von der Stromstärke, der Zinkbromid-Konzentration und dem anfänglichen Wassergehalt des Solvens.Die Molekulargewichte der entstandenen Polymeren (1000-6000) sind unabhängig von der Stromstärke, der Zinkbromid-Konzentration und dem Umsetzungsgrad des Monomeren zum Polymeren, werden jedoch beeinflußt durch Wasser, die Monomerkonzentration und das Elektrodenmaterial. Die chemische Zusammensetzung der Polymeren ändert sich nicht mit der Stromstärke, der Zinkbromid-Konzentration, dem Umsetzungsgrad und dem Elektrodenmaterial. Sie ändert sich jedoch ein wenig mit dem Wassergehalt des Acetons.
    Notes: The electroinitiated polymerization of N-vinylcarbazole (VCZ) in acetone solvent at 25°C with zinc bromide, as catalyst, and platinum electrodes was investigated in detail. The polymerization rate was found to be directly dependent on current strength, zinc bromide concentration and the initial water content of the solvent.The molecular weights of the formed polymers (1000-6000) are independent of current strength, zinc bromide concentration and degree of conversion of monomer to polymer, but are affected by water, monomer concentration, and by the type of electrodes used. The chemical composition of the polymer is invariant with current strength, zinc bromide concentration, degree of conversion, and electrode material but does vary slightly with the water content of acetone.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 4 (1970), S. 145-187 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The influences of the conditioning treatments, surface topography, and crystal structure of carbonaceous surfaces on their ability to sorb heparin and their in vivo compatibility with blood were investigated. The results of the sorption studies indicated that the adsorption of heparin on the surfaces of turbostratic and graphitic materials is not crystallographically selective and that the amount adsorbed on relatively smooth surfaces is near the amount expected for monolayer formation. Although the adsorption of heparin on relatively smooth carbon surfaces is not influenced by the presence of benzalkonium chloride, the sorption of heparin in porous carbons can be greatly increased by a pretreatment with benzalkonium chloride. This increase was found to be due to the formation and entrapment of the insoluble heparin-benzalkonium complex in the accessible porosity. Since the heparin sorptions in Dag-154 coatings were found to be enhanced by a pretreatment with benzalkonium chloride, it was inferred that these coatings contain accessible porosity and that their initial thromboresistance depends on the formation of the benzalkonium-heparin complex in pores. In vivo tests showed that polished and outgassed, impermeable isotropic carbons deposited at low temperatures were significantly thromboresistant without the exogenous application of heparin. There was no relationship between the amount of heparin sorbed on these materials and their compatibility with blood. Polishing, for example, which reduced heparin sorption, enhanced the thromboresistance of these carbons, and while chemisorption of oxygen markedly reduced their thromboresistance, it did not influence the amount of heparin that could be sorbed. Although the heparin-benzalkonium complex sorbed in a porous carbon conferred excellent thromoboresistance in a 2-hr test, the long-tern (14-day) compatibility was not as good as for carbon surfaces that were deposited at low temperatures and then polished and outgassed prior to implanting. In vivo tests of HTI carbon structures and annealed LTI carbons indicate that the blood compatibility of a turbostratic carbon is not significantly dependent on crystallite size, Le. Limited tests of surfaces that had a preponderance of c-faces oriented parallel to the blood-carbon interface at the surface suggest that orientations of this sort are better than others.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Letters Edition 11 (1973), S. 683-688 
    ISSN: 0360-6384
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Letters Edition 11 (1973), S. 149-155 
    ISSN: 0360-6384
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 1973-12-01
    Description: SUMMARYWether sheep were fed on six forage diets, namely, (1) barn-dried low-N hay, (2) barndried low-N hay plus urea infused intraruminally at 12·6 g/24 h, (3) dried sainfoin, (4) dried lucerne, (5) fresh red clover and (6) dried and pelleted red clover. The proportions of amino acids in the diet and in samples of digesta from the duodenum and ileum were determined.The relative proportions of individual amino acids in the duodenal digesta showed little variation despite the differences in intake and the variation in the proportions of amino acids in the feeds. Only the proportions of methionine, lysine, 2:6 diaminopimelic acid (DAPA) and aminoisobutyric acid (AIB) showed significant (P 〈 0·01) variation with respect to diet. In the ileal digesta the proportions of methionine, leucine, tyrosine, phenylalanine, glutamic acid, proline, glycine, alanine, AIB and DAPA showed significant variation by diet.With all diets except lucerne the quantity (g/day) of total amino acids presented at the duodenum was higher than the quantity ingested. There was no correlation between the quantity of total amino acids presented at the duodenum and the quantity disappearing within the small intestine.The duodenal digesta contained a significantly higher (P 〈 0·001) proportion of essential amino acids than did the ileal digesta. This difference was most marked with the diets which supplied a low amino acid intake.With all diets there was little apparent absorption of DAPA in the small intestine.
    Print ISSN: 0021-8596
    Electronic ISSN: 1469-5146
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 12 (1973), S. 647-654 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The primary amine initiated homopolymerization of γ-benzyl-L-glutamate NCA in dioxane at 25°C, 35°C, 50°C, and 65°C has been investigated. The reactions were virtually independent of temperature indicating an activation energy of less than 1 kcal/mole. The entropy of activation was estimated to be -65 entropy units at 300°K. The reaction proceeded in two stages. The first stage was zero-order with respect to monomer, whereas the second was first-order with respect to monomer. Both stages were first-order with respect to initiator. These results were interpreted by assuming that the rate constant for propagation was not independent of the degree of polymerization up to the point where a conformational transition to α-helix occurred.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 12 (1973), S. 1377-1385 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Using Wilson's GF-matrix method as modified by Higgs for infinite helical polymers, dispersion curves and the frequency distribution function have been calculated for poly-L-proline II chain. Infrared spectrum is obtained and a Urey-Bradley force field, which provides best fit with the observed frequencies, is evaluated. The result are discussed from the viewpoint of the conformational characteristics of forms I and II.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...