ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (1,956)
  • Polymer and Materials Science  (1,705)
  • Computational Chemistry and Molecular Modeling  (135)
  • Male
  • 1990-1994  (1,956)
Collection
  • Articles  (1,956)
Keywords
Years
Year
  • 11
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 27 (1993), S. 1349-1355 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Although there are many studies which document high metal ion concentrations in clinically retrieved tissues surrounding total joint replacements, most investigations have remained cautious in their interpretation due to the artifactual influences of metal particulate.The possible contribution of polyethylene wear debris to artifactually high periprosthetic metal ion concentration readings has not been previously considered. This study documents the potential role of polyethylene particulate contamination in causing artifactually high metal concentration readings in tissues.The data showed metal ion contamination in the polyethylene was progressive at each stage of exposure to metal: from bar stock preparation, to manufacturing, to in vivo ambulation. The manufacturing and machining processes showed a statistically significant (P ≤ .05) increase in metal ion concentrations in the nonarticulated acetabular inserts over bar stock.The results of this study demonstrate that periprosthetic tissue and synovial fluid metal ion concentration data must be interpreted with caution due to possible artifactual problems associated with metal ion contaminated polyethylene particulate. © 1993 John Wiley & Sons, Inc.
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 26 (1992), S. 273-289 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We have studied the surface chemistry of two lots of Biomer™ (BSP067 and BSUAOOl), and widely used commercial poly(ether urethane) (PEU). Although transmission infrared adsorption studies revealed no differences in the bulk chemistry of the two lots, the surface chemistry, as seen by x-ray photoelectron spectroscopy (XPS) and static secondary ion mass spectrometry (SIMS), was different. Lot BSP067 showed softsegment enrichment at the surface, which is typical of PEU. Lot BSUAOOl showed no evidence of either hard- or soft-segment PEU components at the surface. The surface of this lot was completely covered with a nonextractable additive identified as poly(diisopropy1 amino ethyl methacrylate). Small amounts of a low-molecular-weight antioxidant were observed at the surface of both samples. Because the biological response to polymers is dependent on surface structure, these results are of considerable importance to biomaterials research.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 405-405 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 15 (1990), S. 265-272 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Surface oxidation reactions of cobalt, molybdenum and mixed cobalt-molybdenum metals have been investigated using x-ray photoelectron spectroscopy (XPS). The oxide stoichiometries have been determined from XPS intensity measurements. Such quantification has been important in identifying oxide compositions with characteristic XPS spectra. A number of discrete binary molybdenum oxides have been characterized after reactions at 200°C and pressures ranging from 1 atm to 10-6 Pa. At the lowest pressure, the Mo 3d spectra and O/Mo ratios suggest the formation of a molybdenum-oxygen structure with a stoichiometry near unity. By contrast, at higher pressures, oxides that are predominantly MoO2 and MoO3 appear, but other intermediate oxide structures are also identified. Well-defined binary oxides of cobalt can be prepared from cobalt metal after heating in oxygen at different pressures. New binary oxides of cobalt and molybdenum have been generated by the reaction on MoO3 or Co3O4 substrates. Oxidation of a thin film of molybdenum on a Co3O4 substrate has been shown to produce a nearly stoichiometric surface layer of CoMoO4. The procedure could be useful for the production of other ternary oxides of possible interest for use as XPS reference materials.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Copper surfaces treated with O2/CF4 and O2/CF4/N2 plasmas have been characterized using x-ray photoelectron and Auger electron spectroscopy. Deeper oxidation and fluorination result for oxygen-rich mixtures than for CF4-rich gas feeds. Film thicknesses increase with time of exposure. Copper oxidation is always deeper than fluorination for O2/CF4 mixtures. It appears that penetration of fluorine is more facile through the copper oxide matrix than through the metallic copper film. With addition of 5% N2, concentration of fluorine is enhanced relative to oxygen. These observations are discussed with respect to gas phase and surface reactions involving oxygen, fluorine and nitrogen.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Secondary ion mass spectrometry has been used to identify the presence of Cu contamination on undoped semiinsulating GaAs wafer surfaces following polishing under certain conditions. The presence of a contaminating species on the wafer surface is indicated by the influence of pre-etch treatments on electrical measurements performed on heat-treated wafers, with and without Si implants. The identification of Cu as a contaminant is confirmed by photoluminescence measurements. With the appropriate wafer preparation process, the level of Cu contamination is below the SIMS detection limit of 〈1 × 1016 atoms cm-3.In the SIMS analysis of the surface-contaminated wafers, the Cu depth profile shape was dependent on the primary beam bombardment energy, suggesting a chemical segregation of Cu out of the altered layer, a redistribution that is known to occur in Si.To quantify the surface concentration of Cu, GaAs wafers were deliberately contaminated with Cu, heat treated and analysed with glow discharge mass spectrometry and SIMS to provide a cross-calibration.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 19 (1992), S. 23-26 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Films of amorphous NbSi prepared by magnetron sputtering were found to have a higher concentration of silicon at the surface than in the bulk material. In this paper we report on measurements of both ultraviolet photoemission spectroscopy and Auger electron spectroscopy carried out on samples prepared in situ at the UK Synchrotron Radiation Source, Daresbury. Spectr taken immediately after sputter deposition show that the surface is rich in silicon, while following argon ion bombardment the bulk composition is slowly revealed with a much greater concentration of niobium. This is observed by a comparison of the relative heights of peaks in the Auger spectra and by resonance effects and the sharpening of the Fermi edge in the UP spectra. Of particular interest are changes around the metal-insulator transition that occur at approximately 11 at.% niobium.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Publication Date: 1992-10-30
    Description: Comparative genomic hybridization produces a map of DNA sequence copy number as a function of chromosomal location throughout the entire genome. Differentially labeled test DNA and normal reference DNA are hybridized simultaneously to normal chromosome spreads. The hybridization is detected with two different fluorochromes. Regions of gain or loss of DNA sequences, such as deletions, duplications, or amplifications, are seen as changes in the ratio of the intensities of the two fluorochromes along the target chromosomes. Analysis of tumor cell lines and primary bladder tumors identified 16 different regions of amplification, many in loci not previously known to be amplified.〈br /〉〈span class="detail_caption"〉Notes: 〈/span〉Kallioniemi, A -- Kallioniemi, O P -- Sudar, D -- Rutovitz, D -- Gray, J W -- Waldman, F -- Pinkel, D -- CA 44768/CA/NCI NIH HHS/ -- CA 45919/CA/NCI NIH HHS/ -- CA 47537/CA/NCI NIH HHS/ -- New York, N.Y. -- Science. 1992 Oct 30;258(5083):818-21.〈br /〉〈span class="detail_caption"〉Author address: 〈/span〉Department of Laboratory Medicine, University of California, San Francisco 94143.〈br /〉〈span class="detail_caption"〉Record origin:〈/span〉 〈a href="http://www.ncbi.nlm.nih.gov/pubmed/1359641" target="_blank"〉PubMed〈/a〉
    Keywords: Chromosome Mapping ; DNA Probes ; DNA, Neoplasm/*genetics ; Female ; Fluorescein-5-isothiocyanate ; Fluorescent Dyes ; Gene Amplification ; Gene Deletion ; Humans ; In Situ Hybridization, Fluorescence ; Male ; Mutation ; Neoplasms/*genetics ; *Nucleic Acid Hybridization ; Oncogenes ; Polymorphism, Restriction Fragment Length ; Rhodamines ; Tumor Cells, Cultured
    Print ISSN: 0036-8075
    Electronic ISSN: 1095-9203
    Topics: Biology , Chemistry and Pharmacology , Computer Science , Medicine , Natural Sciences in General , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Publication Date: 1993-08-27
    Description: Better characterization of human immunodeficiency virus-type 1 (HIV-1) in patients with primary infection has important implications for the development of an acquired immunodeficiency syndrome (AIDS) vaccine because vaccine strategies should target viral isolates with the properties of transmitted viruses. In five HIV-1 seroconverters, the viral phenotype was found to be uniformly macrophage-tropic and non-syncytium-inducing. Furthermore, the viruses were genotypically homogeneous within each patient, but a common signature sequence was not discernible among transmitted viruses. In the two cases where the sexual partners were also studied, the sequences of the transmitted viruses matched best with minor variants in the blood of the transmitters. There was also a stronger pressure to conserve sequences in gp120 than in gp41, nef, and p17, suggesting that a selective mechanism is involved in transmission.〈br /〉〈span class="detail_caption"〉Notes: 〈/span〉Zhu, T -- Mo, H -- Wang, N -- Nam, D S -- Cao, Y -- Koup, R A -- Ho, D D -- AI24030/AI/NIAID NIH HHS/ -- AI25541/AI/NIAID NIH HHS/ -- AI27742/AI/NIAID NIH HHS/ -- etc. -- New York, N.Y. -- Science. 1993 Aug 27;261(5125):1179-81.〈br /〉〈span class="detail_caption"〉Author address: 〈/span〉Aaron Diamond AIDS Research Center, New York University School of Medicine, NY 10016.〈br /〉〈span class="detail_caption"〉Record origin:〈/span〉 〈a href="http://www.ncbi.nlm.nih.gov/pubmed/8356453" target="_blank"〉PubMed〈/a〉
    Keywords: Amino Acid Sequence ; Base Sequence ; Cell Line ; Female ; Gene Products, gag/chemistry/genetics ; Genes, Viral ; Genotype ; Giant Cells/physiology ; HIV Antigens/chemistry/genetics ; HIV Envelope Protein gp120/chemistry/*genetics ; HIV Envelope Protein gp41/chemistry/genetics ; HIV Infections/*microbiology/transmission ; HIV Seropositivity/microbiology ; HIV-1/chemistry/*genetics/*physiology ; Humans ; Macrophages ; Male ; Molecular Sequence Data ; Phenotype ; Sequence Alignment ; Sexual Partners ; *Viral Proteins ; Virus Replication ; gag Gene Products, Human Immunodeficiency Virus
    Print ISSN: 0036-8075
    Electronic ISSN: 1095-9203
    Topics: Biology , Chemistry and Pharmacology , Computer Science , Medicine , Natural Sciences in General , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Publication Date: 1993-09-24
    Description: Rheumatoid arthritis is an inflammatory synovial disease thought to involve T cells reacting to an antigen within the joint. Type II collagen is the major protein in articular cartilage and is a potential autoantigen in this disease. Oral tolerization to autoantigens suppresses animal models of T cell-mediated autoimmune disease, including two models of rheumatoid arthritis. In this randomized, double-blind trial involving 60 patients with severe, active rheumatoid arthritis, a decrease in the number of swollen joints and tender joints occurred in subjects fed chicken type II collagen for 3 months but not in those that received a placebo. Four patients in the collagen group had complete remission of the disease. No side effects were evident. These data demonstrate clinical efficacy of an oral tolerization approach for rheumatoid arthritis.〈br /〉〈span class="detail_caption"〉Notes: 〈/span〉Trentham, D E -- Dynesius-Trentham, R A -- Orav, E J -- Combitchi, D -- Lorenzo, C -- Sewell, K L -- Hafler, D A -- Weiner, H L -- AG00294/AG/NIA NIH HHS/ -- MO1 RR01032/RR/NCRR NIH HHS/ -- New York, N.Y. -- Science. 1993 Sep 24;261(5129):1727-30.〈br /〉〈span class="detail_caption"〉Author address: 〈/span〉Department of Medicine, Beth Israel Hospital, Boston, MA.〈br /〉〈span class="detail_caption"〉Record origin:〈/span〉 〈a href="http://www.ncbi.nlm.nih.gov/pubmed/8378772" target="_blank"〉PubMed〈/a〉
    Keywords: Administration, Oral ; Adult ; Aged ; Arthritis, Rheumatoid/*drug therapy/immunology ; Autoimmune Diseases/*drug therapy/immunology ; Collagen/*administration & dosage/adverse effects/therapeutic use ; Double-Blind Method ; Female ; Humans ; Immune Tolerance ; Male ; Middle Aged ; Placebo Effect ; T-Lymphocytes/immunology
    Print ISSN: 0036-8075
    Electronic ISSN: 1095-9203
    Topics: Biology , Chemistry and Pharmacology , Computer Science , Medicine , Natural Sciences in General , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...