Publication Date:
2019-06-28
Description:
A load-cell-instrumented treadmill mated to a Kistler force plate was used to investigate two methods of force measurement instrumentation during treadmill ambulation in zero g, created by parabolic flight on NASA's KC-135 aircraft. Current spaceflight treadmills do not have adequate instrumentation to determine the resultant foot impact force applied during restrained ambulation. Accurate measurement of foot-ground reaction forces is critical in attaining proper one-g loading, therefore ensuring proper musculoskeletal conditioning. Treadmill instrumentation and force plate measurements were compared for frequency response and linearity. Locomotion impact data were also collected under one-g laboratory settings and in Keplerian flight. The first resonant frequency for both techniques was found to be well above the primary frequency content of the locomotive forces. Peak impact forces measured by the two systems compared to within 10 percent.
Keywords:
AEROSPACE MEDICINE
Type:
NASA-TP-3305
,
S-699
,
NAS 1.60:3305
Format: