ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Column liquid chromatography  (1,216)
  • Springer  (1,216)
  • Blackwell Publishing Ltd
  • Periodicals Archive Online (PAO)
Collection
Keywords
Publisher
Years
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 543-546 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; MS-MS detection ; Electrospray-Ionization (ESI) ; Beer ; Ochratoxin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Ochratoxin A (OTA) is a nephrotoxic and nephrocacinogenic mycotoxin commonly produced by several ubiquitousAspergillus andPenicillium species. OTA is found predominantly in cereals and derived products, and therefore OTA may be transferred into beer from contaminated grain. Thirty-five samples of German beers were analyzed: OTA was extracted with toluene and purified by solid phase extraction using silica cartridges. OTA was determined by high-performance liquid chromatography with fluorescence detection. Since of fluorescence detection is not specific in this instance, the beer samples were also analyzed by high-performance liquid chromatography electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS). OTA levels in the range of 0.1–0.2 μg L−1 were found in 9 beer samples, 21 samples contained trace amounts of OTA (〈0.1 μg L−1) and in 5 samples no OTA was detectable.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Solid phase extraction ; Doxorubicin ; Cell culture media ; Human plasma ; Fluorescence detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Doxorubicin is an antineoplastic antibiotic isolated fromStreptomyces peucetius var.cesius clinically used in the treatment of tumors such as lung or breast, Hodgkin's disease and various types of leukemias. The main goal of this study was to develop a simple and sensitive HPLC method with fluorescence detection for the quantitation of doxorubicin in cell culture media collected during an in vitro studies and in human plasma. Solid phase extraction (C2 silica) was applied. The experiment established five-point standard curve (1 ng mL−1 to 100 ng mL−1). The standard curves prepared in blank cell tissue media were linear over the range of doxorubicin assayed and had a mean correlation coefficient of 0.9973±9.43×10−4 and slope 0.02545±1.85×10−3. The standard curves prepared in human plasma were linear and had mean correlation coefficient of 0.997 and slope 0.01885±5.19×10−4. The limit of quantitation for doxorubicin in both specimens was arbitrarily established to be 1 ng mL−1. Intra-day variabilities were determined using 3–4 replicates of control solutions of doxorubicin (3 ng mL−1 and 30 ng mL−1) in blank plasma and cell culture media. Inter-day variabilities were determined over a four day period analyzing replicates of controls. All precision and accuracy values fell within the acceptable range.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Capillary zone electrophoresis ; Electrospray ionization-mass spectrometry ; Human serum albumin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Human serum albumin (HSA) is one of the most abundant human proteins and has been shown to be heterogeneous. A RP-HPLC method has been developed to separate HSA components in commercially available preparations. Separations were carried out on Aquapore RP-300, C8 columns using gradient elution with a combination of acetonitrile/water mobile phases containing 0.05% trifluoroacetic acid as ion-pairing agent. Optimum resolution was attained on narrow-bore columns using a stepwise, linear gradient that incorporated a shallow intermediate step of 0.20%/min in Mobile Phase B. Under similar elution conditions, separations carried out on standard-size columns showed the expected decrease in resolution due to increased peak widths. A comparative analysis of three commercial products highlighted qualitative and quantitative differences. Capillary zone electrophoresis was used for the analysis of collected RP-HPLC fractions. Results indicated that while the HPLC separation was incomplete, one of the major HPLC peaks was primarily composed of one of the three main components typically separated by CZE. ESI-MS was used to characterize the two major RP-HPLC fractions and also showed that the HPLC separation was incomplete. The MaxEnt transform of the HPLC peaks was consistent with components all being HSA and closely related derivatives.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Amino acids ; FMOC derivatives ; Oligopeptides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary One classical method for quantitation of amino acids in proteins is hydrolysis of the proteins and determination of the free amino acids. Although the drastic experimental conditions necessary for complete hydrolysis always cause degradation of some of the amino acids, if mild hydrolysis conditions are used, a mixture of amino acids and oligopeptides is obtained. If these conditions are adequately tuned, the oligopeptides are almost exclusively dipeptides. For this reason we have initiated a study to find a derivatizing agent suitable for the analysis of amino acids and dipeptides by an absolute method of quantitation already tested for amino acids. FMOC-Cl was found to be a suitable derivatizing agent for this purpose.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 369-373 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Sep-Pak CN cartridge ; Oxytetracycline ; Sulphadimidine ; Meat and eggs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid method for the simultaneous determination/identification of residual oxytetracycline (OTC) and sulphadimidine (SDD) in meats (beef, pork, chicken) and eggs by high-performance liquid chromatography (HPLC) was developed. The extraction of OTC and SDD was performed using a Sep-Pak® CN cartridge. The extracts contained OTC/SDD analytes when examined by HPLC using a LiChrospher® 100 RP-8 end-capped column and a mobile phase of acetonitrile-acetic acid-water (28:4:68, v/v/v) with a photodiode array detector. The average recoveries from spiked samples (0.1 μg g−1 and 1.0 μg g−1) were in excess of 80.2% with coefficients of variation between 1.5 and 5.0%. The limits of detection for OTC and SDD were 0.05 and 0.02 μg g−1, respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Evaporative light-scattering detection ; MALDI-TOF ; Polyethylene glycols
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Polyethylene glycols (PEGs) of nominal molecular weight (M) 200, 400, 600, 1000, 1500, 3000, 4000 and 6000 were chosen as model compounds and subjected to reversed-phase high performance liquid chromatography (RP-HPLC) on an octadecasilyl silica gel (C18) stationary phase using a binary gradient composed of acetonitrile and water and evaporative light scattering detection (ELSD). Satisfactory resolution of oligomers up to M of 3000 was accomplished; the higher M samples PEG-4000 and PEG-6000 could not be further resolved into the constituent oligomers and therefore, M=4000 marks the upper limit of oligomer resolution. Despite some peak overlapping as a consequence of the more or less broad oligomer distribution, individual types of PEG samples can be distinguished from each other by their characteristic chromatographic fingerprint patterns, as shown with a mixture consisting of PEG-400, PEG-1000, PEG-3000, PEG-4000 and PEG-6000. For this reason, the method is well-suited for characterization of samples containing PEGs widely differing in M. In addition, matrix assisted laser desorption ionization time of flight mass spectroscopy (MALDI-TOF/MS) performed with PEG-600, PEG-1000 and PEG-3000 revealed that the optimum degree of oligomer resolution has been achieved by use of the present method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chiral stationary phases ; Crown ether derivatives ; Amino compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The enantiomers of primary amino compounds have previously been resolved on a chiral stationary phase (CSP) CSP-18C6I, prepared by immobilizing (+)-18-crown-6 tetracarboxylic acid. In this study related chiral stationary phases were prepared in an effort to broaden the scope of CSP18C6I. CSP-18C6II, synthesized to investigate the effect of spacer length, resolved the enantiomers of 2-amino-1,2-diphenylethanol and 1-(1-naphthyl)ethylamine (1-NEA) (hydrophobic amino compounds) with the largerk values and smaller α values than on CSP-18C6I, probably because of the greater hydrophobicity of CSP-18C6II. Use of CSP-18C6III, synthesized by modification of carboxylic acid functionality of CSP-18C6II by introduction of another chiral moiety,S-1-NEA, resulted in larger α values for 2-amino-1-phenylethanol and 2-amino-1-phenylpropanol than on CSP-18C6II, but the enantiomers of 1-NEA were not resolved, because of steric hindrance between 1-NEA and the chiral moiety. The amide derivativeN-3,5-dinitrobenzoyl-1-(α-naphthyl)ethylamine (DNN) as π-acceptor (3,5-dinitrobenzoyl function) or π-donor (naphthylethylamide function), and no primary amino functionality, was resolved on CSP-18C6III. The mechanism of separation of the enantiomers of DNN was assumed to be the π−π interaction between the 3,5-dinitrobenzoyl function (π-acceptor) of DNN and theS-1-NEA moiety (π-donor) of CSP-18C6III.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Alcohols ; Pre-column fluorescence derivatization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A sensitive LC method for the determination of alcohols, using fluorescent condensation agent carbazole-9-N-acetylbenzne-disulfonate(CABS), has been developed. A mixture of alcohols and triethylamine catalyst in dichloromethane or chloroform is treated with CABS to give quantitative yields of esters. Emission maximum for the derivatized alcohols is 365 nm (λex 335 nm). The labeled derivatives are very stable, no significant decomposition is observed after heating in 40% at 40°C for 24 h. The method, in conjunction with a multigradient program, offers baseline resolution of common alcohol derivatives on a reversed-phase C18 column. Studies on derivatization conditions indicate that primary and secondary alcohols react very fast with CABS in the presence of triethylamine in dichloromethane or chloroform to give the corresponding fluorescent derivatives. This method is more convenient and more efficient than previous methods which require prior conversion of carboxylic acids to acyl chlorides. The separation of alcohol derivatives has good reproducibility and the rsd's (n=5) for 50 pmol of each alcohol are 4%. Detection limits are at the fmol level.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 42-46 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chiral resolution ; Jasmonic acid ; Plant growth regulators ; Amine conjugates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Racemic jasmonic acid (3R,7R/3S,7S)-(±)-JA) was chemically conjugated with different biogenic amines originating from aliphatic and aromatic α-amino acids by decarboxylation. The resulting isomeric compounds were subjected to reversed-phase high-performance liquid chromatography (HPLC) and to HPLC on the chiral stationary phases Chiralpak AS and Nucleodex β-PM. Under reversed-phase conditions, all the homologous amine derivatives tested could be separated from each other except the JA-conjugates containing 2-phenyl-ethylamine and 3-methylbutylamine. On both chiral supports the (3R,7R)-(−)-JA conjugates eluted earlier than those of the enantiomeric counterpart (3S,7S)-(+)-JA. On Chiralpak AS all the isomers studied could be separated to baseline with a mobile phase containingn-hexane and 2-propanol. The calculated resolution factors were between 1.80 and 4.17. The pairs of isomers were also chromatographed on the cyclodextrin stationary phase Nucleodex β-PM with methanol-triethylammonium acetate buffer as mobile phase. Under these conditions resolution factors were between 0.74 and 1.29. The individual isomers were chiroptically characterized by measurement of their circular dichroism.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Micellar electrokinetic chromatography (MEKC) ; Oral contraceptives ; Ethinylestradiol ; Gestodene
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A micellar electrokinetic chromatographic method is presented which permits quantification of ethinylestradiol and gestodene in pharmaceutical products. Separation was carried out at 25°C and 25 KV, using a 20 mM borate buffer (pH 9.2), 15 mM sodium dodecylsulfate in 30% acetonitrile-water (v/v). Under these conditions analyses were carried out in 7 min. Four different oral contraceptives were analysed and the results compared favourably with those of a reference liquid chromatographic method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Zirconium oxide ceramics ; X-ray fluorescence ; Neutron activation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Lanthania-and yttria-stabilized zirconium oxide ceramics have been examined using High Performance Liquid Chromatography (HPLC), thermal neutron activation (NA) and X-ray Fluorescence (XRF) analyses and thus determine the stabilizer content. Ceramic powders with the composition ZrO2:x mol % La2O3 (x=5, 10, 15, 20 and 33) and ZrO2:x mol % Y2O3 (x=10, 15, 20 and 25) were prepared by the citrate and the co-precipitation techniques, respectively. The lanthanum content was determined by HPLC (x=5.09, 9.78, 14.98, 19.81 and 25.94) and NA (x=5.15, 10.32, 17.25, 21.08 and 27.97) analyses, the yttrium content by HPLC (x=8.5, 13.5, 17.9 and 22.1) and XRF (x=9.9, 15.8, 20.1 and 24.9) analyses. An experimental sequence, based on continuous dilution of ceramic powder solutions, is proposed for preparing samples for HPLC measurements. A swimming pool nuclear reactor is used for NA analysis. The quantitative determinations of yttrium and lanthanum doping levels obtained using those techniques are described.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; α-Chymotrypsin immobilized on silica ; In situ immobilization process ; Structural chiral separations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary α-Chymotrypsin was immobilized on an epoxide derivatized silica gel by anin situ immobilization process. Several racemates were resolved by a structural recognition mechanism. The immobilization process and the stability of this α-chymotrypsin stationary phase have been studied. The mobile phase parameters including the ionic strength, pH and the effects of organic modifiers have been also investigated. The retention, efficiency and stereoselectivity of the solutes appear to be related to their molecular structure, hydrophobicity and electrostatic interactions. These relationships determine the recognition mechanism and the position of each enantiomer in the active site.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Enantiomer separation ; Chiral-AGP column ; Idrapril ; Temperature effect
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A direct liquid-chromatographic method has been developed for the stereoselective analysis of idrapril and its stereoisomers on a chiral α1 glycoprotein (AGP) column. The influence of flow-rate, temperature, and mobile phase composition on retention and selectivity was evaluated to find the optimum conditions for chiral separation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polyfluoroalkyl-coated silica ; 29Si CP/MAS NMR ; Polyaromatic compounds ; Fluorinated compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The conditions for reaction of the branched polyfluoroalkylsilane D3CL with silica gel have been examined. From elemental analyses and29Si NMR spectra it was found that the surface coverage and endcapping of D3CL-coated silica gel (Fluofix®) were the same as for ODS packings. The separation behavior of these phases was compared that of a variety of other packings. For polyaromatic compounds and benzene derivatives Fluofix worked in the reversed-phase mode and its retention characteristics were similar to those of C1 or CN packings. For fluorinated compound the retention characteristics of the phases is similar to those of ODS although with MeOH-water and MeCN-water mobile phases the pressure loss was lower for the fluorinated phases than for ODS.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 699-702 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Anion-exchange chromatography ; High ph elvents ; Monosaccharides ; Carbopac PA-100
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary We have studied the elution behaviour of six common monosaccharides, fucose, galactosamine, glucosamine, galactose, glucose and mannose, on the CarboPac PA-100 column. The relative elution positions of galactose, glucose and mannose were dependent on the sodium hydroxide concentrations, a phenomenon which was likely to be the result of differential ionisation of the hydroxyl groups at ring positions two and four. The optimal resolution of the monosaccharides studied was achieved by elution with 30 mM sodium hydroxide with no appreciable loss in sensitivity at this low concentration.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Meropenem in human plasma ; Solid phase extraction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper describes an HPLC method for the determination of meropenem in human plasma. The method uses solid phase extraction (SPE) of the samples and has good sensitivity, precision and accuracy. The limit of quantification in plasma samples is 0.02 μg mL−1. Calibration curves were linear over a large dynamic range, namely within 0.02–50 μg mL−1. The method was applied to the determination of meropenem levels in patients receiving meropenem, as a single dose or at steady state.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 12-16 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Fatty alcohol sulfates ; Alkyl polyglycosides ; Trace analysis ; Steam distillation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Acid catalyzed hydrolysis of fatty alcohol sulfates under reflux condition or by microwave heating is compared. Microwave hydrolysis turned out to be faster and more convenient to use. The combination of reflux hydrolysis of fatty alcohol sulfates or alkyl polyglycosides and the simultaneous steam distillation of the generated fatty alcohols gives a very powerful sample preparation and enrichment method for fatty alcohol sulfates and alkyl polyglycosides. The preconcentrated fatty alcohols are derivatized and detected via fluorescence detection. The applicability of the method is demonstrated by the analysis of fatty alcohol sulfates in cosmetics and in river water as matrices spiked with approximately 4 ppb fatty alcohol sulfates.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; DAD and MS detection ; Liquid-solid extraction ; Catechin derivatives ; Myricetin derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A liquid-solid extraction and purification procedure (LSE) was developed to identify and quantify polyphenols in the leaf tissue ofMyrtus communis L. Identification and quantitation of individual compounds was performed using HPTLC, HPLC-DAD and HPLC-MS analysis. Leaves ofMyrtus communis L. contain small amounts of phenolic acids (caffeic, ellagic and gallic acids) and quercetin derivatives (quercetin 3-O-galactoside and quercetin 3-O-rhamnoside), whereas catechin derivatives (epigallocatechin, epigallocatechin 3-O-gallate, epicatechin 3-O-gallate) and myricetin derivatives (myricetin 3-O-galactoside, myricetin 3-O-rhamnoside) are present in large amounts. This is the first report on the occurrence of galloyl-derivatives of catechin and gallo-catechin inMyrtus communis L. leaves.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Glycolytic enzymes ; p-Hydroxymercuribenzoate ; 203Hg-labelledp-hydroxymercuribenzoate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of hydrophobic-interaction chromatography (HIC) is proposed for the simultaneous determination of more than one thiol-protein after formation of the corresponding mercury mercaptides withp-hydroxymercuribenzoate (PHMB). The new chromatographic procedure, based on the HIC separation of the modified proteins from each other and from excess organomercury reagent has been successfully applied to the quantitative determination of phosphoglucose isomerase (PGI) and phosphoglucose mutase (PGM) in crude PGI powder, and of L-lactate dehydrogenase, PGM and aldolase in crude pyruvate kinase from rabbit muscle. The suitability of203Hg-labelled PHMB has been tested in the analysis of mixtures, which give barely distinguishable UV-peaks owing to the presence of other non-thiol components in the sample. For this purpose glyceraldehyde 3-phosphate dehydrogenase (GAPDHy) and PGIy from bakers yeast have been considered. Results obtained in experiments performed by both procedures are reported.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chiral stationary phases ; Benzophenone imine derivatives ; Amino acid esters ; Enantiomer separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The liquid-chromatographic separation of the enantiomers of amino acid esters as benzophenone Schiff-base derivatives on polysaccharide-derived chiral stationary phases (CSPs) is described. The performance of Chiralcel OF was superior to that of the other CSPs for resolution of benzophenone imine derivatives of amino acid ethyl and methyl esters. The enantiomers of most of the amino acid esters examined as their benzophenone imine derivatives were resolved to baseline on Chiralcel OF. The L-(−) enantiomers of all the analytes were preferentially retained on Chiralcel OF. The resolution of several imine derivatives of amino acid esters was investigated, as was the effect of eluent composition on the resolution of amino acid ethyl esters as their benzophenone imine derivatives.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Amperometric detection ; Clozapine ; Desmethylclozapine ; Drug monitoring
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A high-performance liquid chromatographic method with amperometric detection has been developed for the determination of levels of clozapine (CLZ) and its active metabolite N-desmethylclozapine (DMC) in human plasma. The analysis was performed on a 5 μm C8 reversed phase column (150×4.6 mm i.d.), with acetonitrile-phosphate buffer (pH 3.5), as the mobile phase. The detection voltage was +800 mV and the cell and column temperature were 50°C. Linear responses were obtained between 2 ng mL−1 and 100 ng mL−1. Absolute recovery for both clozapine and desmethylclozapine exceeded 88% and the detection limit was 1 ng mL−1. Repeatability, intermediate precision and accuracy were satisfactory. The method, which is rapid, sensitive and selective, has been applied to therapeutic drug monitoring in schizophrenic patients following administration of Leponex® tablets. In 21 patients in steady state at a mean daily clozapine dosage of 358 mg (ranging from 150 to 500 mg day−1), clozapine levels averaged 379 ng mL−1 (ranging from 102 to 818 ng mL−1) and DMC levels averaged 233 ng mL−1 (ranging from 70 to 540 ng mL−1). The method requires only a very small amount of plasma (100 μL), and thus it is suitable for pharmacokinetic studies, as well as for therapeutic drug monitoring.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Cyclodextrin additives ; Fluorescence agents
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary We report four new derivatization agents, acridone-N-acetic acid (ARC), carbazole-9-ylacetic acid (CRA), carbazole-9-ylpropionic acid (CRP), and 2-methyl-2-carbazole-9-ylacetic acid (MCRA), with strong fluorescence emission which has low dependence on solvent polarity. The emission maxima for ARC, CRA, CRP, and MCRA were 430 nm (λex 404 nm), 368 nm (λex 335 nm), 356 nm (λex 340 nm) and 360 nm (λex 330 nm), respectively. The effects of mobile-phase composition, pH, and temperature on the liquid chromatographic retention behavior of the four fluorescence agents were investigated. An experimental model was established for calculating the inclusion constants of cyclodextrin (CD) complexes in the dynamic state, using β-cyclodextrin (β-CD) and hydroxypropyl-β-cyclodextrin (HP-β-CD) as examples, and different mobilephase compositions. On the basis of the model, the inclusion constants of the solutes in pure water (K fw) were determined by extrapolation. The thermodynamic parameters (ΔH o and ΔS o) and dissociation constantsK am for the solutes in this chromatographic system were obtained by means of capacity factor (k) values using a corresponding model formulation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Interaction of mobile and stationary phases ; Linear solvation energy relationships ; Triethylamine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The effect of triethylamine (TEA) in the mobile phase on the RPLC retention behavior of small organic solutes has been studied on a conventional polymeric octadecylsilica (ODS) and on a horizontally polymerized ODS. Retention factors for a set of solutes were measured on the two phases with methanol-water mobile phases containing triethylamine at different concentrations and analyzed by use of linear solvation energy relationships (LSER). Variation of the resulting LSER coefficients—v (hydrophobicity),r (polarizability),s (dipolarity),b (hydrogen-bond (HB) donating acidity), anda (HB accepting strength)—were examined to see how TEA affects the intermolecular interaction properties of the mobile and stationary phases and hence the retention of the solutes. Addition of TEA to the mobile phase changes the interaction properties of both conventionally polymerized and horizontally polymerized ODS; the effect is greater for the conventional phase. The HB donating acidity (b) of conventional polymeric ODS is significantly reduced by addition of TEA. For the mobile phases studied the magnitudes of theb andv coefficients for the horizontally polymerized ODS phase are greater than for the conventional phase. The different interaction properties of the two polymeric phases arise mainly as a result of differential adsorption of TEA, because of the very different amounts of surface silanol groups present on the two phases.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; p-tert-Butyl-calix[4]arene-bonded silica ; Nuclear magnetic resonance spectrometry ; PAHs ; Nucleosides bases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new method is proposed for preparation of ap-tert-butyl-calix[4]arene-bonded silica stationary phase. The chemically modifiedp-tert-butyl-calix[4]arene is attached to silica gel via the silane coupling reagent γ-(ethylenediamino)-propyl-triethoxyl-silane. The bonded phase has been characterized by29Si and13C cross polarization/magic angle spinning solid-state nuclear magnetic spectrometry. The retention behavior of polycyclic aromatic hydrocarbons (PAHs), nucleosides and bases has been investigated on the bonded phase in the reversed-phase mode.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 671-677 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Microwave hydrolysis ; Microcystin ; Nodularin ; D- and L-selective amino acid determination
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Microwave radiation has been successfully used for hydrolysis of the hepatotoxic cyclic peptides microcystins and nodularin. Set-up of the microwave device and the operating conditions for microwave hydrolysis were optimized. Results of the microwave hydrolysis were compared with results from conventional hydrolysis for 24 h at 110°C. Microwave hydrolysis of microcystins and nodularin for as little as 10 min at 160°C results in complete cleavage of peptide bonds and high recoveries of amino acids. Enantioselective determination of amino acids was achieved by use of a previously described HPLC method after pre-column derivatization withortho-phthaldialdehyde and the chiral thiolN-iso-butyryl-cysteine.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Hydroxypropyl-β-cyclodextrin ; Imidazole derivatives ; Retention mechanisms ; Enthalpy-entropy compensation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two different methods have been used to investigate the retention mechanism of a series of imidazole derivatives in reversed-phase liquid chromatography (RPLC) over a range of column temperatures and with different concentrations of hydroxypropyl-β-cyclodextrin (HP-β-CD) in the mobile phase. The first approach was the separate study of each factor affecting the retention mechanism; the second method was the simultaneous variation of all these factors. Changes in Van't Hoff plots as a function of HP-β-CD concentration were examined. Enthalpy and entropy were determined for two physicochemical processes: (i) solute transfer from the mobile phase to the stationary phase, and (ii) solute complexation by HP-β-CD. These thermodynamic data showed that the mechanism of retention of the solute was dependent on the concentration of HP-β-CD in the mobile phase. For a HP-β-CD concentration,C, greater than to 4 mM, from 28°C to a critical temperature,T *, solute retention was entropy-dominated because of inclusion of the solute in the HP-β-CD cavity. AboveT * retention was enthalpy-dominated, because of interaction of the solute with the RP18 stationary phase. At firstT * increased asC was increased up to a critical value,C **; it the remained relatively constant because of auto-association of the HP-β-CD molecules in the mobile phase. Enthalpy-entropy compensation revealed that HP-β-CD-solute complexation had a greater effect on retention than RP18 stationary phase-solute interaction. This confirms that the main parameter determining retention in RPLC is the distribution of the solute in the mobile phase, and that interactions with the stationary phase play a minor role.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Non-aqueous reversed-phase liquid chromatography ; Evaporative light-scattering detection ; Octadecyl grafted silica ; Ceramides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper describes the development of a chromatographic system for analysis of commercial ceramides structurally similar to those found in the stratum corneum. The ceramides used in this study contain different amine based (phytosphingosine, sphingosine and dihydrosphingosine) and fatty acids of different chain lengths and with different functional groups (hydroxylated and unsaturated). Non-aqueous reversed-phase (NARP) liquid chromatography with evaporative light-scattering detection (ELSD) were the techniques chosen in accordance with the nature of the ceramides. The eluent strength and the potential selectivity of different organic solvents were investigated. On a C18-bonded silica, the most promising chromatographic conditions employed a gradient from ACN-THF, 95∶5, to ACN-THF-PrOH, 35∶5∶60, in 15 min with a constant concentration of TEA (10 mM) and a stoichiometric amount of formic acid.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 281-284 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Glucosinolates ; Rapseed-mustard ; Brassica
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple, economical and efficient HPLC method has been developed for the separation and determination of the individual glucosinolates in rapessed and mustard. The method involves single-step extraction of glucosinolates with boiling water and separation of the individual glucosinolates on a Novapack RP-18 column (3.9 mm ×150mm) with 0.2 M ammonium sulphate as mobile phase. Peaks were monitored at 229 nm. All major glucosinolates could be eluted within 10 min. The method proved effective for routine analysis of glucosinolates.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 535-538 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Solid phase extraction ; Herbicides in soil ; Flupoxam
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary High-performance liquid chromatography with UV detection was used to determine the residues of flupoxam (a new herbicide) in soils. Soil samples were extracted with aqueous methanol. The soil extracts were cleaned up and concentrated using two solid phase extraction columns: a polymeric stationary phase based on a polystyrene-divinylbenzene resin (Lichrolut EN) and alumina. Recovery experiments were performed at ppb levels in spiked soil samples. The recovery was 76±1.7% for flupoxam in the range 5–100 μg kg−1 of soil. Limit of determination was 3 μg kg−1.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; α-Chymotrypsin-CSP ; Enzymatic chiral separations ; Loadability evaluation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Several racemates has been resolved according to an enzymatic recognition mechanism on an α-chymotrypsin chiral stationary phase. The loadability of the ACHT-CSP has been evaluated both in buffered and non-buffered mobile phases under the enzymatic process and compared with the loading capacity obtained by the structural recognition process.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Enantioseparations ; Amylose phenylcarbamate phase ; Glycidyl sulfides ; Glycidyl selenides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The resolution of the enantiomers of a series of glycidyl sulfides and glycidyl selenides has been examined on a chiral stationary phase prepared by coating aminopropylated silica gel with amylose tris-(phenylcarbamate). Most of the enantiomers of glycidyl monosulfides and monoselenides could be resolved satisfactorily but those of the disulfides could not. The effects of solute structure and of the concentration of 2-propanol in the mobile phase on retention and resolution were investigated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Cis-diamminedichloroplatinum (II) ; Transdiamminedichloroplatinum (II) ; Amminetri-chloroplatinate ; 4-Methyl-2-thiouracil
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary We have developed a simple, rapid, selective and sensitive method for detecting the antitumour agent cis-diamminedichloroplatinum (II) (cisplatin) (CDDP) and its toxic impurities trans-diamminedichloroplatinum (II) (transplatin) (TDDP) amminetri-chloroplatinat (ATCP) anion using HPLC in one run. By using 4-methyl-2-thiouracil (MTU) as a derivatizing agent, new compounds have been formed from the Pt compounds and separated on a μ-Bondapak C18 column with isocratic elution and detection at 315 nm. Reactant concentration, methanol content, pH and the reaction time on yield of derivatives were investigated and the optimum conditions for the detection response were defined. The derivatives of each of the three platinum compounds formed in an acetate buffer solution containing 40% (v/v) methanol and 0.9% KCl solution at pH 3.7 and ambient temperature were only stable for one hour.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 306-308 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Digoxin and digoxigenin ; Temperature effects ; Pore size effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Increased retention of digoxin has been observed at elevated temperatures on both 10 nm and 30 nm porediamter, RP-18 packing. This result is the opposite effect compared with the decreased retention under the same conditions with digoxin aglycon-digoxigenin. Rotation around the C−C σ-bonds in the digoxin molecule is presumed; the rod-like molecules of the newlyobtained digoxin penetrate stationary phase pores more easily thus increasing retention.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ion chromatography ; Monovalent anions determination ; Potentiometric detection ; Ion selective PVC-matrix electrode
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An all solid-state contact tubular PVC-matrix membrane electrode has been applied for potentiometric detection of inorganic and organic monovalent anions using phosphate and hydrogen phosphate eluents at low concentrations. This is a “monovalent detection method” as the selectivity of the electrode towards monovalent anions results in some other anions being undetected unless the concentration of those other anions is higher than 10−3 mol dm−3 in the sample solution injected. It takes only eight minutes to complete the separation with a good resolution. Theoretical and practical considerations are discussed, and in particular, sensitivity, linearity, detection limit and dynamic behaviour are presented. The use of an all solid-state contact bromide-selective electrode as a detector offers so far the best simultaneous sensitivity toward all anions when compared with other detection methods. Determination of Cl− and NO3 − ions in river, rain and drinking water samples without any further sample preconcentration has been successfully achieved. The detection limit is sub-ppb for most of anions in a 20 μL injection volume.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Evaporative light scatering detection ; APCI mass spectrometry ; Triacylglycerols
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Short- and long-chain triacylglycerols (SLCT) are a family of lipids prepared by chemical or enzymatic interesterification of triacetin, tripropionin and/or tributyrin, and long-chain (C16!18) hydrogenated vegetable oils. In this study, a normal-phase cyanopropyl high-performance liquid chromatographic (HPLC) method was developed for the separation and quantification of SLCT. The method is capable of separating SLCT mixtures, free fatty acids and the neutral lipid classes of saturated long-chain triacylglycerols, diacylglycerols and monoacylglycerols. To characterize the specific SLCT classes, a normal-phase HPLC procedure using a non-modified silica column was developed to separate the SLCT into individual isomers based on total carbon number and position of fatty acids on the glycerol backbone. Online coupling with a mass detector (LC/MS) allowed the identification of the individual triacylglycerol structures.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. 424-430 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Octadecyl titania ; Surface hydrosilation ; Solid-state NMR C7
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The structure of a C18 phase based on titania (C18-A), synthesized by the method of solution polymerization, is investigated by diffuse reflectance infrared Fourier transform (DRIFT) and solid-state nuclear magnetic resonance (NMR) spectroscopy. The findings are compared with the results of a second C18 phase based on titania (C18-B) which was synthesized by the method of surface hydrosilation. The dynamic behavior of both phases is examined by1H MAS NMR detection of spinlattice relaxation times in the rotating frame (T1pH) and conventional spin-lattice relaxation times (T1). Due to a smaller ligand density, phase C18-A appears to be a somewhat more mobile than phase C18-B. The chromatographic capability of the phase C18-A is demonstrated by the separation of samples containing benzene derivates or anilines. The elution order is analogous to the phase C18-B, but for both test mixtures the polarity of the mobile phase has to be increased. Phase C18-A is classified as being polymeric by the Sander and Wise test, whereas phase C18-B shows intermediate retention behavior.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; NMR spectroscopy and mass spectrometry ; Plant products ; Silene otites
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary HPLC coupled in parallel to nuclear magnetic resonance (NMR) and mass spectrometry (MS) has been used to obtain1H NMR and mass spectra of a number of ecdysteroids present in an extract of the plantSilene otites. Reversed phase gradient chromatography was performed using a D20-acetonitrile-based solvent system. NMR and mass spectra were obtained for integristerone A, 20-hydroxyecdysone, 2-deoxy-20-hydroxyecdysone and 2-deoxyecdysone to provide structural confirmation using continuous and stopped flow HPLC-NMR. The combined HPLC-NMR-MS system described here provided a more comprehensive analysis of the ecdysteroids present in the extract than HPLC-NMR alone.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; O-alkyl, O-(1-methylthioethylideneamino) phosphoramidates ; Quantitative structure-retention relationship (QSRR) ; Reversed-phase LC
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary By using factor analysis, cluster analysis and multiple linear regression methods, two parameters, FHF and ECCR, were selected from eight solute-related structure parameters as showing the best correlation with retention data. The relationship between the retention data (k) and these two structure parameters were established for ten O-alkyl, O-(1-methylthioethylideneamino) phosphoramidate compounds under the experimental conditions studied. Retention data (k) for six other compounds that have a high correlation with structure parameters were predicted using these QSRR equations. The system was evaluated by comparing the experimentalk values with the predicted ones. Good agreement was obtained between the experimental and predictedk values.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 25-34 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Solid Phase Extraction ; RP-HPLC gradient analysis ; Taxus Cell Cultures ; Taxol and Taxanes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Solid phase extraction (SPE) methods are studied for the sample pretreatment for HPLC analysis ofTaxus cell suspension cultures. Various types of SPE materials were tested for the extraction of both the taxane standards and samples of various origin. Comparison between the different cartridges and the different elution solvents are made in terms of extraction recovery and sample clean-up. Selective elution of the taxanes is achieved by a gradient elution scheme.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 77-80 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ion chromatography ; Stability constants ; Ionic strength ; Heavy metals ; Tartaric acid
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Ion chromatography and potentiometry were used for the determination of the stability constants Pb, Zn, Co, Ni, Mn tartrate complexes at different ionic strengths. An extrapolation function based on the Debye-Hückel equation was applied to obtain the thermodynamic stability constants.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ion-pair LC ; Plasma ; 2,4-Toluendiamine ; 2,6-Toluendiamine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An ion-pair HPLC method is presented for the determination in plasma of 2,4- and 2,6-toluendiamine (TDA), known carcinogens. The chromatographic conditions consisted in isocratic elution on a reversed phase C18 column with 5 mM octanesulfonic acid in methanol-water, 45∶55, as mobile phase. UV detection was performed at 235 nm. Samples were analyzed after a simple single step liquid-liquid extraction and the method was validated by measurement of precision (interassay and intraassay), sensitivity, specificity, linearity, and recovery. The detection limit for both TDAs in plasma was 20 ng mL−1. The correlation coefficients based on the intrassay calibration curve were 0.998 and 0.997 for 2,6- and 2,4-TDA, respectively. The intraassay accuracy, expressed in terms of recovery, was found to be up to 89.91% and 97.05% for 2,6- and 2,4-TDA, respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Enantiomer separation ; Voriconazole (UK-109,496) ; Effect of organic mobile-phase modifier
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Coupled achiral-chiral high-performance liquid chromatography (HPLC) with an achiral amino-based column coupled with a chiral amylose-based column has been used for qualitative and quantitative determination of the potential chiral and achiral impurities of Voriconazole (UK-109,496), a new antifungal agent with two stereogenic centres. The effect of the organic mobile-phase modifier, ethanol, was studied. The assay response was linearly dependent on concentration over the range 1.2–40.4 μg for Voriconazole and 2.5–104.0 ng for the impurities. The limit of detection was 2.5 ng for each analyte.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ion chromatography ; Titania packings ; Inorganic anions and cations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The ion-exchange retention behavior of titania synthesized in our laboratory was investigated by ion chromatography of inorganic anions and cations. Dilute acetic acid-sodium acetate and bicine-sodium hydroxide buffers were used as mobile phases with no use of suppresor. We observed that the titania, although poor at separating monovalent anions expcept nitrite ion in this experiment, was both an anion and a cation exchanger, and selectively retained fluoride and carbonate ions. We concluded that because of its specific retention properties there were possibilites of using this amphoteric exchanger for simultaneous analysis of anions and cations, and of using it as a selective packing material for ion chromatography.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Porous graphitic carbon ; Optimization ; Morphine and metabolites
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The chromatographic behaviour of a series of morphine-based opiates has been investigated using a porous graphitic carbon packing material at acid and alkaline pH. The effects of mobile phase pH, mobile phase organic percentage, column temperature and ionpairing agents were studied. All six opiates were separated within a close retention window despite large differences in measured lipophilicities of the individual opiates. The retention order was not related to the log P values of the opiates and strong retention of the fully ionised compounds was observed, particularly those with acidic functional groups. The effect of pH on the retention of the compounds indicated that the degree of ionisation of the individual compounds was important in the separation mechanism, suggesting that hydrophobic interactions were present in addition to the polar retentive effects observed above. The strong retention of the ionised glucuronide and sulphate conjugates of morphine is a particularly useful feature of the porous graphitic carbon packing material which has general applicability to the analysis of polar or ionised drug metabolites.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Amperometric detection ; Solid-phase extraction ; Plasma ; Clozapine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A sensitive and selective high-performance liquid chromatographic method has been developed for monitoring clozapine levels in human plasma. Chromatography was performed on a reversed-phase column (C8, 150 mm×4.6 mm i.d., 5 μm) with acetonitrile-aqueous sodium acetate solution, 88∶12 (v/v), as mobile phase; the flow rate was 1 mL min−1. Clozapine oxidation at +800 mV was detected amperometrically. Response was linearly dependent on concentration over the range 50–1500 ng mL−1 clozapine in plasma. Sample preparation by solid-phase extraction before HPLC analysis gave high extraction yield (94%). The accuracy and precision of the method were both very good (recovery: 97%;RSD〈3.3%).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 299-304 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Plasma samples ; Direct injection ; Restricted-access media ; Column-switching
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new restricted access media (RAM) type of precolumn, Bio Trap 500 C18, for direct injection of plasma samples in column-switching systems was evaluated with respect to the elution of plasma proteins in different mobile phases, the loading capacity of plasma samples, the chromatographic behavior during plasma injections and protein contamination of the packing and sealings. More than 95% of plasma proteins could be excluded from the precolumn within three minutes for all selected mobile phases. Quantitative analyte recoveries could be obtained by injecting plasma samples ranging from 5 to 500 μL with the analyte mass〉150 ng onto a BioTrap 500 C18 column (20×4 mm I.D.). One precolumn tolerated about 15 mL of plasma injection without out noticeable change in retention and pressure. Clogging of the precolumn was encountered (≥45 mL of plasma) due mainly to the adsorption of proteins on the packing. The performance of the analytical column (Kromasil C18) was also examined. The column efficiency decreased by 60% after processing 45 mL plasma in total.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 373-382 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polyaromatic hydrocarbons ; Pitch
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new high performance liquid chromatography method for the characterisation of toluene-soluble fractions of pitches has been developed. Although a chromatographic system typical of size exclusion chromatography was used, results indicate that, for these structurally complex samples, separation does not follow the usual discrimination by molecular size. A differentiation between several classes of polyaromatic hydrocarbons is achieved instead. Data are reported on the analysis of individual standard polyaromatic hydrocarbons, showing that four different elution ranges can be observed: three ofcata-condensed compounds (Cata1, Cata2 and Cata3) and one ofperi-condensed compounds (Peri). Results are reported proving the capacity of this high performance liquid chromatography method to distinguish between pitches of different origin and nature. It is also effective for the study of the chemical reactions occurring during heat treatment.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Opium alkaloids ; Papaver somniferum L.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A reversed phase HPLC method for the separation of the five major alkaloids fromPapaver somniferum L., morphine, codeine, thebaine, papaverine and noscapine, has been developed and validated. By use of a basedeactivated silica-based stationary phase excellent peak shape was achieved for each substance. The five alkaloids were quantified by internal standardization within 20 min and with good precision. The method is applicable to opium and to poppy straw.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Carbofuran pesticides ; On-line analysis of milk
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method has been developed for extraction and determination of carbofuran in milk. The method involved direct injection of raw milk on to a human serum albumin dimethyloctyl-silica gel (HSA-C8) column and the use of 80:20 (v/v) 0.01 M phosphate buffer pH 5.5-acetonitrile as mobile phase. UV spectrophotometric detection was performed at 220 nm. Identification was based on retention time. Quantification was performed by automatic peak-area determination and was calibrated by use of an external standard.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 17-19 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Dibromomannitol in plasma ; Pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Myelobromol 1,6-dibromo-1,6-dideoxy-D-mannitol (dibromomannitol, DBM) is a bifunctional alkylating agent that has been in clinical use since 1963. It is currently included at high dose in preconditioning regimen for bone marrow transplantation (BMT) and is a main-stay of treatment for polycythaemia vera. A high-performance liquid chromatographic method was developed for the determination of DBM in the plasma. The basis of the assay is a derivatization with sodium-diethyldithiocarbamate at 42°C in the presence of 1-bromo-1-deoxy-3,6-anhydro-galactitol as internal standard (IS). The analysis was carried out on a 250×4mm Hypersil 5 CPS column equipped with a 20×4 mm Hypersil 10 CPS precolumn. The eluent consisted of heptane:isopropyl-alcohol: glacial acetic acid=600:76:80 w/w. The flow rate was 1.2 mL min−1. UV detection was performed at 254 nm. The calibration graph was linear in the concentration range of 2.5–260 μM of DBM in plasma. The limit of detection was 1.0 μM. The precision and accuracy of the method was between the good laboratory practice (GLP) required limits.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 37-42 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Biologically active amines ; Polyamines ; Cereal and Cereal products
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Biologically active amines (putreanine sulphate, N-acetyl putrescine, putrescine, cadaverine, histamine, agmatine, N-acetyl spermidine, spermidine, spermine) were separated and quantified in cereal flour and cereal products by a liquid chromatographic method. The method consists of the separation of ion pairs formed between biologically active amines and octanesulphonic acid on a reversed-phase column, postcolumn derivatization with o-phtalaldehyde-2-mercapthoethanol and spectrofluorometric detection. Results of the reliability study were satisfactory. The method was linear for each amine at 1–10 mg L−1. Putrescine and spermidine were the only amines always detected in cereal flour and cereal products, ranging from 2.45 to 47.83 mg kg−1 for putrescine and 3.27 to 37.14 mg kg−1 for spermidine. The most important differences among types of samples were found in polyamine derivatives.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Normal- and reversed-phase LC ; Fumagillin in fish samples
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Fumagillin is an antibiotic agent mostly used in the veterinary profession. A normal-phase liquid chromatographic method was developed for the determination of this drug in fish matrices. A hexane-dichloromethanedioxan-2-PrOH-acetic acid (43:43:9:5:0.1 v/v %) eluent was used on a Perkin Elmer silica gel column. For validation of the process a reversed-phase HPLC method was also developed (eluent: acetonitrile-water-bicyclohyxylamine 70:30:0.05 v/v %, with Spherisorb ODS, as stationary phase). Recovery is about 100% and the limit of detection is 5 ng g−1 for meat samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Buckminsterfullerene ; Hydrogenation ; Separation technique
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The effect of composition and flow rate of the mobile phase on the HPLC separation of hydrogenated buckminsterfullerene (C60Hn n=2–38) was investigated on BuckySep column. Toluene was used as the basic solvent and hexane, heptane, cyclohexane, THF, acetonitrile, acetone, ethanol and 2-propanol as co-solvents. The fraction of co-solvents was varied 10–80%, and the flow rate 1–0.1 mL min−1. Toluene-acetonitrile 65∶35 and toluene-acetone 50∶50 provided the best separation. Under the best conditions complete separation of C60H2 and almost complete separation of the four most abundant isomers of C60H4 were achieved. Separation of derivatives with higher hydrogen content was very poor.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 440-442 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Preparative scale separations ; Chiral stationary phase ; Enantiomer separation ; Morphanthridine analog
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparative chromatographic enantioseparation of a chiral morphoanthridine analog has been performed on an analytical column using amylose-tris(3,5-dimethylphenylcarbamate) as chiral stationary phase. The racemate (100 mg) was resolved to baseline within 15 min. This paper describes the development of the method, estimation of the capacity of the chiral stationary phase and discussed the potential of the chromatography if performed under preparative conditions. From the results and calculations presented it seems likely that the resolution of 70 tons year−1 could easily be achieved on 30 kg of stationary phase with a mobile-phase consumption of only 720 L day−1.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 449-450 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chitin stationary phase ; Marrubiin ; Analgesic activity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Marrubiin is the main active compound isolated fromM. vulgare, a medicinal plant used in folk medicine to cure several diseases. The present study shows that chitin, an abundant natural polymer, may be successfully in chromatography column to separate marrubiin from complex mixtures. The experimental procedure described here represents an efficient and rapid method to obtain such compound in high yield.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Affinity chromatography ; Molecular imprinting ; Molecular recognition ; Combinatorial libraries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Molecular imprinting is an attractive method for producing highly selective adsorbents, and several new and potentially useful applications based on molecularly imprinted polymers (MIPs) have been described in recent years. In this article, we highlight some of the areas where these materials have found application, and also describe some new fields of application where the selectivities of imprinted materials can be gainfully employed, for example as binding matrices in the screening of combinatorial libraries, and as auxiliary agents in enzymatic syntheses.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Fermentation ; Microdialysis sampling ; Monosaccharides and ethanol ; On-line monitoring ; Biosensors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two amperometric biosensors were used as detection units in liquid chromatography for on-line monitoring of the production of fuel ethanol during a fermentation. Sampling was performed with a microdialysis probe, and the dialysate was introduced into a liquid chromatographic system providing separation of the substrates and the product: three monosaccharides and ethanol. The analytes were detected by two carbon paste electrodes based on pyranose oxidase and alcohol oxidase, respectively, co-immobilised with horseradish peroxidase, operating in parallel at −50 mVvs. Ag/AgCl. The measured linear ranges of the biosensors by direct injection into the LC system were for glucose 0.3–2.5 g L−1, xylose 0.5–6.7 g L−1, galactose 0.5–6.7 g L−1, and ethanol 1.6–11.7 g L−1, respectively. Injection of standard solutions were required to monitor the stability of the biosensors. Due to the strict selectivity of the biosensors, no interference from other compounds in the broth was encountered from other compounds in the broth was encountered in the quantification. The fermentation process was monitored for 16 h. The on-line results were compared with off-line measurements.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Cisapride in plasma ; Pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An HPLC method has been developed for the quantification of cisapride in plasma for pharmacokinetic studies. Clebopride was used as internal standard. Plasma samples were extracted at alkaline pH withtert-butyl methyl ether. The organic phase was then extracted with sulphuric acid to eliminate endogenous interferences, and cisapride and the internal standard were then extracted at alkaline pH intotert-butyl methyl ether. After evaporation oftert-butyl methyl ether, the residue was analysed by HPLC. Chromatography was performed at 20°C on a 250mm×4mm i.d. reversed-phase column selective for basic compounds. The isocratic mobile phase was 48∶52 (v/v) acetonitrile-water containing 0.05 M potassium dihydrogen phosphate and 0.04 M triethylamine, adjusted to pH 5.5; the flow rate was 1 mL min−1. Cisapride and the internal standard were detected by ultraviolet monitoring at 276 nm. The calibration graph was linear for quantities of cisapride from 1 to 200 ng mL−1. Intra- and inter-day precision (CV) did not exceed 13.98%. The limit of quantitation (LOQ) was 0.68 ng mL−1 for human plasma. The applicability of the method has been demonstrated in a pharmacokinetic study of normal volunteers who received 10 mg cisapride orally.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 285-290 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Enantiomeric separation ; β-Cyclodextrins ; Methylenedioxylated amphetamines ; Ecstasy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Native and derivatized β-cyclodextrins such as chiral stationary phases (CSP) were used for the simultaneous enantiomeric separation of four methylenedioxylated amphetamines (MDA, MDMA, MDEA and MBDB) by liquid chromatography. Fluorimetric detection was used in order to enhance sensitivity and selectivity. The mobile phase was, optimised by studying the influence of pH, triethylamine concentration, organic solvent type, column temperature and flow rate of the mobile phase. This method was validated by determining linearity, precision, accuracy, limits of detection and quantification, and was applied to the stereoselective analysis of illicit tablets (23 samples) and of human whole blood samples (spiked samples and two post-mortem cases). Whereas no significant deviation from a racemic ratio was observed in the tablets contents, the analysis of blood samples showed an enantioselective metabolism of MDMA.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Aminopropyl-silica sorbent ; Continuous cleanup/preconcentration ; Hydroxyvitamin D3 metabolites ; Flow injection analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new procedure for continuous cleanup and concentration of hydroxyvitamin D3 metabolites prior to their separation by HPLC and UV-detection is reported. The process is based on the use of aminopropyl-silica as solid-phase sorbent as an alternative to the use of nonpolar sorbents. The improvement thus achieved has been tested by comparing the results with those obtained using octadecyl-C18 as non-polar sorbent. The comparison has been based on the calibration graphs (linear range, detection and quantitation limits), precision and multiple standard addition method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Coulometric detection ; Mandelic acids ; Phenylglycols ; Urine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method has been developed for the quantification of urinary 3,4-dihydroxymandelic acid (DOMA), 4-hydroxy-3-methoxymandelic acid (VMA), 3,4-dihydroxyphenylglycol (DHPG), and 4-hydroxy-3-methoxyphenyglycol (MHPG). Separation and determination of these compounds in biological samples was previously thought to be very difficult. In this work the separation has been achieved by reversed-phase high-performance liquid chromatography with step-wise gradient elution with three mobile phases. The conditions for coulometric detection have been optimized for effective determination of these compounds. In analysis of a sample of human urine, after a simple deproteinization proceudre, DOMA, VMA, DHPG, and MHPG were separated from interferences and quantified successfully; the average levels of these compounds in six different samples were 33.87±1.03, 1202±41.3, 31.3±1.92, and 80.6±2.15 μg (24 h)−1, respectively. Their precursors E, MN, DOPA, DA, NE, DOPAC, HVA, 3MT, and NMN, and the indolamine 5HT and its metabolite 5HIAA (a list of abbreviations is given at the end of the paper) can also be determined simultaneously in the same chromatographic run. The overlapping peak of DHPG was resolved by deconvolution.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Optimization ; Mixture design ; Special cubic polynomial model ; Pareto-optimality ; Overlapping resolution mapping (ORM)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A systematic approach, using a mixture-design statistical technique, has been developed for selecting the optimum mobile phase for the separation of fat-soluble vitamins in reversed-phase high-performance liquid chromatography. A quaternary mixture of methanol, acetonitrile, tetrahydrofuran and water was used as mobile phase. Retention time and peak width were recorded in ten runs augmented with five replicates and the data were subsequently fitted to special cubic polynomial models. The resulting mathematical equations enabled prediction of resolution over the entire parameter space. Contour plots of minimum effective resolution and maximum retention time as a function of mobile phase composition are presented and discussed. Visual inspection of these plots provides an overview of the quality of the separation and the analysis time required for each possible mobile-phase composition with n the parameter space. It is demonstrated that the methodology followed was an important tool which enabled the taking of informed decisions necessary for selection of the optimum mobile phase for a chromatographic separation. A combination ofR S minimum andt R maximum as optimization criteria in a multicriteria decision-making plot using pareto-optimality concept is discussed. This combination enabled visual demonstration of the compromise between separation quality and the economics of analysis time. Our methodology has been compared with the common used technique of ‘overlapping resolution mapping’.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 457-464 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Imprinted polymer ; Non-covalent imprinting ; Selectivity and capacity ; Association constant
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Imprinted polymers as stationary phases for HPLC separations have been the subject of extensive investigations in recent years. In order to aid the rational design of synthetic protocols for the preparation of imprinted polymers, a series of calculations were made to assess the equilibrium concentration of templatemonomer complexes as a function of association constant (K) for the functional groups involved in the interactions and initial concentrations of reactants. This data was then used to predict the selectivity of polymers prepared under different reaction conditions and the model was tested using an experimentally determined value ofK and separation factors taken from the literature.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; N-(dansyl)-dl-amino acids ; Human serum albumin ; Chiral discrimination ; Optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The effect of perchlorate anion as mobile phase modifier on the separation factor, α, forN-(dansyl)-dl-norvaline andN-(dansyl)-dl-tryptophan on a human serum albumin (HSA) column was studied by varying the concentration,c, of the chaotropic agent and the column temperatureT. Gibbs-Helmholtz parameters Δ(ΔH) and Δ(ΔS) between thed andl enantiomers were determined from linear van't Hoff plots of lnα against 1/T. Thermodynamic results indicated that the enhancement of the separation factor observed asc was increased was enthalpically controlled owing to stereoselective H-bonding interactions. Such behavior was used to optimize the chromatographic conditions for separation ofN-(dansyl)-amino acids on HSA.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Solid phase extraction ; Sample treatment optimisation ; Taguchi method ; Albendazole metabolites ; Milk samples
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Reversed phase HPLC methods for the determination of two metabolites of albendazole in cow's milk are described. Albendazole is an anthelmintic agent used both in veterinary and human practice. Its main metabolites are albendazole-sulfoxide and albendazole-sulfone. The separation of the two metabolites was performed on a μ-Bondapak C-18 column using an acetonitrile/methanol/phosphate buffer as mobile phase, with detection at 290 nm. For the sample preparation of the milk samples we used solid phase extraction. A new sample treatment optimisation procedure is also presented for the sample preparation method. Since sample preparation is a critical step in the analysis of residues in biological samples, the second part of our publication describes an optimisation using Taguchi's methodology that increased recovery, accuracy and reliability. After optimisation of the sample preparation, the limit of detection was 10 ng mL−1 milk and the recovery was 70–80% in the concentration range of 30–1000 ng mL−1 milk for both metabolities.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ketotifen analysis ; Stability indicating analysis ; Aqueous and oil-based formulations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple and specific high-performance liquid chromatographic (HPLC) method for the analysis of ketotifen in aqueous solutions and silicon oil suspensions is described. The HPLC system is based on a reversed phase μBondapak C18 (30×0.39 cm) column with a mobile phase of phosphate buffer (0.001 M, pH 7.4):methanol: acetonitrile: trimethylamine (29.8:45:25:0.2, by volume) at a flow-rate of 1 mL min−1. The eluent was monitored by UV absorption at 299 nm. Silicon oil-based samples were extracted with HCl (0.05 M) using imipramine as internal standard. The recovery of ketotifen and imipramine was greater than 80%. The calibration curves for both assays were linear over the ranges examined, yielding correlation coefficients greater than 0.997. The assay was shown to be stability indicating by subjecting solutions of ketotifen in phosphate buffer to heat, oxidative stress and irradiation with ultraviolet light (254 and 369 nm)for up to 8 h. The methodology was also shown to be applicable for the analysis of ketotifen in simple aqueous based formulations, in suspension in silicon oil and for the analysis of samples derived fromin vitro skin transfer experiments.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 43-47 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Vitamin C analysis ; Ascorbate-2-phosphate and sulphate esters ; Enzyme shifting
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method was devised to assay four forms of vitamin C: L-ascorbic acid (AA), dehydroascorbic acid (DHA), ascorbate-2-mono- and polyphosphate (AMP, APP), as well as ascorbate-2-monosulphate (AMS), in sample series of different fish tissues and feed. Direct and indirect detection were combined. Sample extractions were carried out with 0.2 mol L−1 sodium acetate buffer (pH 4.8) and extracts were deproteinized after different chemical or enzymatic reactions, with perchloric acid. The DHA was reduced to AA with dithioerythritol (DTE). Ascorbate oxidase enzyme was used for the detection of background and an acidic phosphatase enzyme for the hydrolysis of different phosphate esters. Ascorbate-2-sulphate was detected directly with help of coinjection of the compound. Chromatographic analysis was carried out with a single column isocratic reverse phase method. The mobile phase was an aqueous buffer of 0.04 M sodium-acetate, 0.05 mM EDTA, 0.5 mM tetrabutylammonium dihydrogen phosphate (TBA) adjusted to pH 3.76 with 85% H3PO4 and with 24 mL methanol added to 1000 mL. C-18 columns were used with 0.6 mL min−1 flow rate at 23°C. The vitamin C forms were detected by UV absorption at 250 nm. The determination limit was 1.0–5.0 μg g−1 in AA equivalent. The standard deviations were between 1–6% and depended on the concentrations of vitamin C forms and tissues. Recoveries were between 90–96% in samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Multicomponent mixtures ; Separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Coupling of full adsorption-desorption and size-exclusion chromatography (FAD-SEC) has been applied to the separation and molecular characterization of three- and four-component polymer blends. The method is based on the full adsorption of alln orn−1 components of the polymer blend in a specially designed FAD minicolumn. By appropriate eluent switching the adsorbed polymers are desorbed stepwise from the FAD minicolumn into an on-line SEC column for molecular characterization. It is shown that the desorption isotherms of particular blend components give valuable information about the appropriate displacer composition. The exact position of the desorption isotherms depends, however, both on the amount of polymer adsorbed and in the presence of other, chemically different, polymers within FAD column. The nature and composition of the displacer must, therfore, be adjusted if the intervals between the desorption of particular blend components are to be large enough to prevent displacement overlap.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 360-364 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Acylated anthocyanins ; Rudbeckia hirta L. ; In vitro cultures
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Conditions were determined for the separation of a complex set of anthocyanins (free aglycones, mono- and multiglycosides and esterified forms) by HPLC. The optimised gradient elution method was then used to carry out qualitative and quantitative analysis of anthocyanin compounds present in the callus tissue ofRudbeckia hirta L. and the tubular flowers of the soil-based plant. The summary content of anthocyanin pigments and the content of the main pigment was identified in the analysed biomass. The method developed is useful for the purposes of monitoring the process of biosynthesis of anthocyanins in tissues obtained through in vitro cultures. The advantages of the method for anthocyanins and its application to other anthocyanin-rich materials are also discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Basic drug compounds ; Amino additives ; Cyanoalkyl columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The separation of basic antidepressant and antipsychotic drugs on a cyanoalkyl-bonded silica column has been studied to determine the effects on peak retention, symmetry, efficiency, and resolution of six different amine mobile-phase additives. The amines—ammonia,n-butylamine, triethylamine,N,N-diisopropylethylamine,N,N-dimethylbutylamine andN,N-dimethyloctylamine—were, except forN,N-diisopropylethylamine, chosen because of their widespread use for improvement of peak symmetry in chromatographic methods;N,N-diisopropylethylamine was included as an example of a sterically hindered amine to see if the stereochemistry around the nitrogen atom is an important consideration in the selection of an additive. This study shows that a gain in symmetry and efficiency is accompanied by loss of resolution. The results obtained also indicate that one type of amine additive should be used when symmetry and efficiency are most important and another when resolution is paramount.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Amphotericin B ; Oil-water lecithin-based microemulsions ; Extraction of drug from microemulsion ; Reversed-phase HPLC
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method employing extraction then reproducible reversed-phase high-performance liquid chromatography (RPHPLC) with monitoring of the drug by absorbance at 405 nm has been developed and validated for the determination of amphotericin B in oil-water lecithin-based microemulsions. The precision and accuracy of the method are excellent (SD 2.4% and 4.2%, respectively). The established linearity range was 10–60 μg mL−1 (r 2=0.9967). The recovery of amphotericin B from spiked placebo was 〉90% over the linear range. The extraction procedure was simple and the HPLC conditions were able to separate the drug from its degradation products and excipients. The method has been used successfully for determining the amphotericin B content of microemulsions and for evaluating the chemical stability of amphotericin B-loaded microemulsions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 183-189 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polymeric phases ; Shape selectivity ; PAH selectivity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Stationary phases with octadecyl groups have been prepared with different carbon content without and in the presence of water and characterized for their selectivity for the shape of various polyaromatic hydrocarbons. It is shown that both a high hydrocarbon content and a good accessibility of the bonded groups within the pores is required to achieve shape recognition for PAH. High carbon content alone is not sufficient. The two tests for shape selectivity proposed by Sander and Wise as well as by Tanaka are compared. In most cases the results are similar: A low selectivity with the Sander and Wise test (α TBN/BaP〈1) corresponds to a high value with the Tanaka test (α TRI/o-TER〉3). However, not in all cases the tests give corresponding answers. Further studies on molecular recognition are required.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 197-202 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Molecular imprinting ; Molecular recognition ; Chiral recognition
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Molecularly imprinted polymers were prepared using 2-vinylpyridine and/or methacrylic acid as functional monomers in a self-assembly imprinting protocol. The resulting polymers were analyzed in aqueous media, and the effects from the pH of the mobile phase and the degree of added organic solvent were investigated. The results are indicative of the importance of ionic bonds in conjunction with hydrophobic interactions in the formation of the complexes between the analyte and the polymers.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 190-196 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ion-interaction chromatography ; Dye-coated reversed phase ; Retention model ; Experimental design
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The separation of inorganic anions (NO3 −, NO2 −, Cl−, Br−, I−, SO4 2−, S2O3 2−) by ion-interaction chromatography mediated with a specific dye has been investigated. Chromatography was performed on a LiChrospher RP-18 colum dynamically coated with crystal violet, using acetonitrile-water buffered with phthalate as the mobile phase. The presence of the dye in the eluent enabled indirect spectrophotometric detection of the analytes, which have no significant UV absorption. Retention data were collected for the different anions by varying the composition of the mobile phase according to a full factorial experimental design. A theoretical model for the retention of singly- and doubly-charged analytes, on the basis of the two main processes of ion-exchange and ion-pair formation, has been proposed and validated with the experimental data.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 209-214 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Covalent chromatography ; Thiophilic and hydrophobic ligands ; Wheat β-amylase ; Salt promoted adsorption
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The behaviour of wheat β-amylase from crude extracts in chromatography on agarose gels substituted with different ligand types was investigated. The enzyme displayed high salt promoted adsorption onto thiophilic gels provided with sulfone-thioether and 2-thiopyridine ligands. Quantitative recovery of the enzyme was easily accomplished by elution with buffer in the absence of Na2SO4. The 3-(2-pyridylthio)-2-hydroxypropylagarose (PyS-gel) also allowed elimination of pigments present in the wheat extract. These pigments showed no adsorption onto the gel, thus regeneration is easily achieved, allowing its re-use. The enzyme also displayed strong salt-dependent adsorption onto adsorbents provided with pyridyldisulfide moieties, but in this case enzyme binding was due to its thiol content since elution was achieved mainly through reduction with DTT. When the enzyme was chromatographed on a series of hydrophobic alkyl ligands in the presence of 0.5 M sodium sulphate, it was partially adsorbed on pentylagarose and quantitatively adsorbed on hexyl-agarose, elution being easily performed by sodium sulphate-free buffer. This behaviour was markedly different from that towards phenyl-Sepharose, to which the enzyme was strongly adsorbed and which required much more drastic elution conditions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chromatographic behavior ; pH optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The effects of pH on both the solute retention and the peak shape of ionogenic compounds are studied in order to propose accurate models for pH optimization purposes. Several mathematical models (theoretical and empirical) for describing the variation of the retention factor versus pH are compared within different pH ranges. Limits of such models used for optimizing the pH by requiring only 3 preliminary experimental runs, are discussed in terms of deviations (≤±5%) of predicted retention times from experimental retention times. An original procedure is developed for selecting the most convenient retention model, from a given set of three retention data. This set is also applied to modeling the variation of both peak width and peak asymmetry with mobile phase pH conditions. Such a procedure is demonstrated as helpful for the separation of ionogenic solutes by considering mobile phase pH as an additional variable that can be useful during optimization procedures.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Retention mechanism ; Donor-acceptor complex ; Molecular interactions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Charge-transfer interactions are often assumed to be dominant among the noncovalent interactions that govern the solute retention in electron donor-acceptor chromatography. This popular view, however, has been called into question by recent studies that suggest an important role for electrostatic interactions in the formation of donor-acceptor complexes. We reported here an experimental investigation concerning the question as to whether charge-transfer or electrostatic interactions are the driving force for solute retention in donor-acceptor chromatography. Using three chromatographic systems composed of a dinitrobenzene derived stationary phase and a hexane based mobile phase, we determined retention factors for a range of aliphatic and aromatic hydrocarbons and correlated them with molecular properties that describe the solute's dispersion, charge-transfer, and electrostatic characteristics. It was found that the molecular polarizability and ionization potential give either very poor or no correlation with solute retention whereas the molecular quadrupole moment is a linear function of the logarithmic retention factor. These results were interpreted as showing that electrostatic, rather than charge-transfer or dispersion, interactions play a major role in determining solute retention. The dominance of the electrostatic interactions over the other noncovalent interactions was discussed in terms of distance dependency of the interaction energy.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 584-588 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Circular dichroism detection ; Multiscan detection ; Peak purity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method has been developed to detect inhomogeneity of apparently homogeneous peaks of very similar analytes. The method utilizes the rapid scan feature of state-of-the-art spectrometers/detectors that allow the recording of up to 30 spectra in a single chromatographic peak. Sensitivity and selectivity are enhanced by chiroptical/optical detection. Thus, identification of “front” and “rear” components of the peak can be carried out. The method is exemplified by mixtures of codeine, hydrocodone and oxycodone as analytes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 589-590 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Berberine in plasma ; Ischemic heart failure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Berberine absorption by patients with ischemic heart failure (IHF) after oral administration and the relationship between clinical effect and plasma berberine concentration are studied. Plasma samples were pretreated by chloroform extraction. Berberine was determined on a μBondapak column with acetonitrile-phosphoric acid mobile phase and UV detection. The limit for berberine in plasma was 8 ng mL−1 for an injection volume of 50 μL. Average berberine recovery was 96.5%. Results showed that improvements in symptoms were more significant for patients with plasma berberine concentration〉0.1 mg L−1 than for those with〈0.1 mg L−1. Plasma berberine monitoring may be helpful in the treatment of patients with IHF.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Micellar liquid chromatography ; Diethyldithiocarbamates ; Metal complexes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper presents the, chromatographic retention of Co(II), Ni(II) and Cu(II) as diethyldithiocarbamate complexes in the presence of hexadecyltrimethylammonium bromide/ethanol/water systems, as mobile phase, by reversed phase high performance liquid chromatography. The presence of an organic modifier reduces the retention times and improves the efficiency. In order to evaluate the interaction between the metal complexes and the mixed micellar system the values of solute binding constants are calculated in, two ways: a) Arunyanart and Cline-Love's treatment and b) multiple regression analysis taking account of the ethanol percentages.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Homocysteine ; Human plasma ; Routine analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Elevated plasma homocysteine is, a known risk factor in arteriosclerotic vascular disease. To measure homocysteine in a large number of samples, we have developed a rapid, simple, robust and inexpensive reversed-phase HPLC method for routine analysis. Mercaptopro-pionylglycine was used as the internal standard and an external calibration in plasma was performed. Improvement was achieved by the use of gradient elution (using a sodium acetate buffer and methanol) resulting in a higher number of samples analyzed per day. Plasma samples were reduced with tributylphosphine and the proteins were precipitated with perchloric acid before addition of internal standard. The analytes were derivatized by use of 7-fluorobenzofurazone-4-sulfonic acid ammonium salt. For calibration human plasma was spiked with nine different concentrations of homocysteine (range 2–50 μmol L−1). The inter-assay precision of replicate (n=29) analysis of the concentration of homocysteine in a sample of pooled plasma was 3.0%. The limit of detection, defined as three times the signal-to-noise ratio, was 0.25 μmol L−1. The linearity of the assay was confirmed for a plasma concentration range of 2–2000 μmol L−1. The variation of duplicate analyses of 842 plasma samples was 2.6±1.7%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Tramadol andO-demethyl tramadol in plasma ; Pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A sensitive liquid chromatographic assay for the quantitative determination of the opioid analgesic tramadol and its active metabolite is described. Fluconazole was used as internal standard. The assay involved a singletert-butyl methyl ether extraction and LC analysis with fluorescence detection. Chromatography was at 30°C pumping an isocratic mobile phase of acetonitrile-water (19∶81, v/v) containing 0.06M NaH2PO4 and 0.05M triethylamine, adjusted to pH 7.90, at 1 mL min−1 through a reversed-phase, 250×4 mm base-stable column. The limit of quantitation of tramadol and its active metabolite was 1 ng mL−1, only 0.5 mL plasma sample was required for the determination. The calibration curve was linear from 1–1000 ng mL−1. Intra and inter-day precision (C.V.) did not exceed 10%. Mean recoveries of 96.38% for tramadol and 96.62% forO-demethyltramadol with CVs of 0.43% and 1.46% were obtained. Applicability of the method was demonstrated by a pharmacokinetic study on normal volunteers who received 100 mg tramadol intravenously.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 48 (1998), S. 561-568 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Planar chromatography ; S-Carboxymethyl-L-cysteine ; Metabolic studies
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The analysis of 08:00–16:00 (0–8) hour urine collections following oral S-carboxymethyl-L-cysteine administration of 750 mg to 30 individuals identified S-carboxymethyl-L-cysteine, S-carboxymethyl-L-cysteine S-oxide, S-methyl-L-cysteine and S-methyl-L-cysteine S-oxide as the major urinary drug related compounds. No S-(carboxymethylthio)-L-cysteine mixed disulphide metabolite was found in the 08:00–16:00 hour urine collection but the metabolite was detected in the 16:00–00:00 (8–16) hour urune collection by paper chromatography, TLC and HPLC. The production of the S-oxide metabolites 08:00–16:00 hour urine collection) and the mixed disulphide metabolite (16:00–00:00 hour urine collection) were both shown to be biomodally distributed. A significant linear correlation of the S-oxides recovered following 08:00–16:00 hour urine collection as analysed by paper chromatography, TLC and HPLC is reported.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Normal phase gradient elution ; Polyester resins
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Polymers can be characterized by gradient elution techniques in order to obtain information on their chemical composition and molar mass. In this paper, features and applications of Normal Phase Gradient Polymer Elution Chromatography (NP-GPEC) for the characterization of (co)polyesters are investigated. Two polyesters were characterized, using various stationary and mobile phases. Separation was shown to be dominated by end groups in most cases, and to a lesser extent by molar mass. A distinct influence of both column type and mobile phase type was observed. A polymer based polyamine (PA) column povided the best results, although no complete separation between the mono- and di-acid fractions could be obtained. In all cases, separation was governed by sorption rather than by precipitation/redissolution. NP-GPEC was shown to be a potentially interesting technique for the characterization of copolyesters according to the chemical composition of the backbone, independent of end groups.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Enantiospecific analysis ; N-Ethyl-N-methylaniline ; N-Oxidation ; N-Dealkylation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A robust, sensitive reverse-phase high-performance liquid chromatographic (HPLC) method for the quantification of the majorin vitro oxidative microsomal metabolites of the prochiral tertiary amineN-ethyl-N-methyllaniline (EMA) is described. The analytes were resolved on a Spherisorb 5 ODS1 HPLC column using an acetonitrile/phosphate buffer system under isocratic conditions. Use of solid-phase extraction (SPE) and ultraviolet (UV) detection at low wavelength (210 nm) enabled the detection of EMAN-oxide simultaneously with the majorN-dealkylated metabolites,N-ethyl andN-methylaniline. Previous chromatographic methods described for the quantification ofN,N-dialkylarylamineN-oxides have generally required sample pretreatment to reduce theN-oxide to its parent tertiary amine prior to analysis. The above method, in combination with a previously reported chromatographic resolution based on the Chiralcel OD chiral stationary phase (CSP), allows accurate and precise determination of both the quantity and stereochemical composition of metabolically derived EMAN-oxide.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chlorophyllc ; Marine phytoplankton ; Octylsilica phases ; Photosynthetic pigments
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The separation of mono- and divinyl chlorophyllc forms was estudied employing several octylsilica and octadecylsilica columns under isocratic conditions. In this paper we show that, using the adequate mobile phases, the monomeric C8 columns can separate the mentioned chlorophylls. A comparison between C8 and C18 columns reveals that monomeric OS phases provide always higher resolution of the MV- and DV chlorophyllc pairs. Such a result could be explained in terms of differences in column polarity. When adequate gradient profiles and injection conditions are used the separation is accomplished together with that of other chlorophylls and carotenoids.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 637-642 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ligand-exchange chromatography ; Chiral stationary phases ; Enantiomer separation ; Amino acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Chiral stationary phases (CSPs) were synthesized by reaction of aminopropylsilica (APS) with chiral monochloro-s-triazines (MCTs). MCTs were obtained by reaction of 2,4,6-trichloro-s-triazine (cyanuric chloride) with one equivalent of methanol and, subsequently, with one equivalent of L-prolinetert butyl ester (H-Pro-OtBu) orN-tert butyloxycarbonyl-L-lysinetert butyl ester (Boc-Lys-OtBu). End-capping of unreacted amino groups of APS with acetic anhydride, followed by trifluoroacetolytic cleavage of the protecting groups of amino acids (AAs), afforded two chiral stationary phases bearing either L-proline (CSP-3) or L-lysine (CSP-4) as chiral selector. Using ligand-exchange chromatography matography with addition of Cu2+ to the mobile phase, enantiomers of free DL-AAs and a fewN-(2,4-dinitrophenyl)-DL-AAs were separated on CSP-3, whereasN-(dansyl)-DL-AAs were separated on CSP-4.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Atmopheric Pressure Chemical Ionization (APCI) mass ; spectrometry ; Glucuronide-conjugates ; Toxicological compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new chromatographic method for the direct determination of metabolites (glucuronide-conjugates) of molecules of toxicological relevance in biological media with the minimum sample pre-treatment has been developed. A high performance liquid chromatographyatmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) system was used for this purpose. The separation of four glucuronides Aminophenylglucuronide (APhG), Phenylglucuronide (PhG),p-Nitrophenylglucuronide (NPhG) and α-Naphthylglucuronide (NG) was obtained under ion-suppressed reversed-phase chromatography conditions, by using high-speed (3 cm, 3 μm) columns and formic acid (2 mM) as the acid modifier in the mobile phase. Different C-18 stationary phases (partially endcapped and non-endcapped) were evaluated in order to obtain retention for these very polar, water soluble molecules. The ionization of the analytes was obtained in negativeion (NI) mode. Detection limits were in the range 1–5 mg L−1 and calibration curves were linear over two order of magnitude. Intra-day and inter-day precision were in the range 2.9–10.6% for all the compounds. The method was successfully applied for the determination of PhG in a urine sample of a European Quality Assurance Programme for Organic Solvent Metabolites.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Column liquid chromatography ; Solid-phase microextraction ; Local anaesthetic lidocaine ; Optimisation of extraction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Solid-phase microextraction (SPME) has been combined with gas chromatography (GC) and liquid chromatography (LC) for the determination of lidocaine in human urine. A polydimethylsiloxane (PDMS) coated fibre was directly immersed into buffered urine. Extraction conditions such as time, pH, ionic strength, temperature, and agitation were optimised. The extracted lidocaine was thermally desorbed in a split/splitless injector for analysis with a GC-FID system or desorbed with liquid in a specially designed SPME-LC interface for analysis with an LC-UV system. After optimisation the method developed was evaluated and validated. Extraction yields of 22% were obtained in about 45 min. The reproducibility of the method is 〈5% (relative standard deviation). For five-times diluted urine, linear ranges were found from 5–1000 and 25–1000 ng·mL−1 for SPME-GC and SPME-LC, with detection limits of 5 ng·mL−1 for SPME-GC and 25 ng·mL−1 for SPME-LC. SPME can be used as a simple sample pretreatment method for the determination of lidocaine in urine by GC and LC.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Vitamin A in flour and milk powder ; Method validation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An experimental and statistical approach is presented which enables, with a minimum of determinations, the validation of a high-performance liquid chromatographic (HPLC) method for the determination of vitamin A in milk powder and flour for children. The principal aspects of method validation are examined and discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Nitric acid ester phase ; Alkyl nitrates ; Group separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The synthesis of a nitric acid ester NP-LC stationary phase (organonitrate phase), by nitrating a commercial polyol phase (Serva, Polyol Si 100, 5 μm) with mixed sulfuric-and nitric acid, is reported. The nitric acid ester bond is quite stable towards hydrolysis. To examine its possible use as a stationary phase for the group separation of alkyl nitrates, several bifunctional polar alkyl nitrates (di-nitrates, hydroxy-nitrates, keto-nitrates) have been synthesized. In order to simplify their names a new abbreviating nomenclature for multifunctional organic nitrates is presented. With our new stationary phase it is possible to separate mono-, di-, and hydroxy-nitrates as groups completely, a major advantage in sample preparation in the chemistry of smog formation. However a co-elution of di- and keto-nitrates is observed. A distinction of the latter two organonitrate groups is possible by gas chromatography-mass spectrometric detection (MSD). Apart from the fragment ion NO2 + (m/z=46 amu), which is nearly specific for alkyl nitrates, aliphatic di- and keto-nitrates show different characteristic fragment ions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 197-202 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Non-volatile strawberry compounds ; Multivariate analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A procedure is presented for simultaneous extraction of organic acids, vitamin C and sugars from strawberries and analysis by reversed-phase (RP) HPLC and cationexchange (calcium form) chromatography. Recoveries from strawberries spiked at different levels ranged from 96 to 103 % for carbohydrates, 92 to 112 % for organic acids, and 84 % for vitamin C; the repeatability of the method evaluated as the relative standard deviation in the optimum range was 〈5 % for sugars and 7.5 % for organic acids and vitamin C. Multivariate analysis techniques, such as Bayes and SIMCA analyses, have enabled correct classification of the strawberries tested but we were unable to establish adequate models for typifying them according to their geographic origin.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; NMR and MS detection ; Ibuprofen metabolites ; Urine extracts
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of HPLC-NMR-MS for the detection and identification of the metabolites of ibuprofen present in a solid phase extract of human urine is described. Gradient reversed-phase HPLC was used to separate the components present in the extract, which were then characterised by a combination of stopped-flow1H NMR and on line electrospray-MS. This approach led to the rapid identification of the known phase 1 human metabolites of ibuprofen, including hydroxy- and carboxy- metabolites, together with their respective glucuronide conjugates. In addition a probable artefact resulting from the dehydration of one of the side chainhydroxylated glucuronides was also identified.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 47 (1998), S. 291-298 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Capillary electrochromatography ; Rapid analysis ; Short columns ; Rapid gradients
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Rapid analyses were performed using reversed-phase liquid chromatography with short (20–100 mm) columns swept by fast yet shallow gradients, and the results compared with those obtained with 150 mm columns and slow gradients. The resolution losses incurred with shorter columns were minimised by employing elevated flow rates, to ensure that comparable mean retention factors were experienced by individual analytes during gradients run on different columns. This conserves gradient steepness. High quality performance was obtained with turn-around times of 5–10 minutes. An overall 5-fold enhancement in the rate of information generation was obtained. The relevance of instrumental parameters and of column and packing dimensions, upon the potential for improved performance is discussed. Some implications for the rapidly developing technique of capillary electrochromatography are briefly indicated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Stationary phase characterization ; Silica packing materials ; Cyclodextrins ; Partially methylated β-cyclodextrins
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The chromatographic properties of five columns packed with phenyl-bonded phases were characterized by an approach based on Tanaka's method for column to column comparisons in order to develop an LC analysis of partially methylated β-cyclodextrins. The retention behaviour of β-cyclodextrin, heptakis(2,6-di-O-methyl)-β-cyclodextrin and heptakis(2,3,6-tri-O-methyl)-β-cyclodextrin was examined in order to evaluate the different interactions between phenyl stationary phase and this family of compound. Chromatograms show that the residual silanol activity of the packing materials plays a beneficial role in the partially methylated β-cyclodextrins separation process. It is concluded that knowledge of the interactions involved allows one to make a reasoned choice of the stationary phase in order to obtain the best possible analysis of three different commercial samples of partially methylated β-cyclodextrins.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ranitidine ; Plasma ; Pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An HPLC method has been developed for the quantification of rantidine in plasma for pharmacokinetic studies. Metoclopramide was used as internal standard. The method uses a simple and rapid sample clean-up procedure involving single-step extraction with organic solvent to extract ranitidine from plasma. After evaporation and reconstitution the samples are chromatographed on a 250 mm×4 mm base-stable reversed-phase column with 0.05 M ammonium acetate-acetonitrile, 75∶25 (v/v) as mobile phase and UV detection at 313 nm. The calibration graph was linear for quantities of ranitidine between 10 and 2000 ng mL−1. Intra- and inter-dayCV did not exceed 11.64%. The quantitation limit was 10 ng mL−1 for human plasma. The applicability of this method for pharmacokinetic studies of ranitidine after oral administration are described. Approximately 90 samples can be processed in 24 h.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; EGIS-9933 ; Solid phase extraction ; Rat plasma
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new highly sensitive high-performance liquid chromatographic (HPLC) procedure for determination of EGIS-9933 (a newly developed anxiolytic compound) in rat plasma is described. A gradient, elution method with UV detection at 270 nm has been developed using a mobile phase of a mixture of A: methanol:acetonitrile 1:9 and B:0.5% triethilamine in water, the pH of B was adjusted to 3 with phosphoric acid. Solid phase extraction (SPE) was used for the sample preparation. The calibration was linear in the 10–10000 ng mL−1 concentration range. The limit of quantification was 10 ng mL−1. The bioanalytical method was validated according to internationally accepted criteria for biological samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ion-pair chromatography ; Food related-biogenic amines ; Heptanesulphonate ; Octylamine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An ion-pair HPLC method based on the simultaneous use of heptanesulphonate and octylamine has been considered with the aim of optimizing the separation of four food-related biogenic amines (histamine, tyramine, 2-phenylethylamine and tryptamine) and related precursor aminoacids. On changing the eluant pH from 2.70 to 3.20 the capacity factor of precursor aminoacids decreased and those of the biogenic amines increased; pH 3 allowed an optimal separation. An increase of phosphate content, from 6.0 mM to 12.0 mM, shortened the capacity factors. The addition of octylamine to the eluant reduced the peak asymmetry (especially for histamine from 3.20 to 1.69). Some samples of cheese showed a concentration of total amines up to 1284.8 mg L−1; wines and beers showed a very similar total content, ranging from 0.5 mg L−1 to 27.2 mg L−1.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    ISSN: 1612-1112
    Keywords: Gas chromatography-mass spectrometry ; Column liquid chromatography ; Supercritical fluid extraction ; Bile acids ; Bovine bile hydrolysates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of supercritical fluid extraction (SFE) as an alternative to conventional liquid extraction has been investigated to conventional liquid extraction has been investigated for the isolation of bile acids (cholic acid, deoxycholic acid and chenodeoxycholic acid) from the solid material obtained by bovine bile hydrolysis. Initial studies indicated that bile acids are not soluble in supercritical CO2, consequently the addition of the polar modifier methanol to the CO2 extracting fluid was evaluated. Quantitative recoveries (〉88.5%) were obtained for the bile acids in 20 min with 15% (v/v) methanol in CO2 at 220 atm and 70°C. A comparison of SFE with pyridine extraction was performed on samples of hydrolyzed crude bovine bile. The SFE method yielded recoveries higher than 82.7% compared with conventional liquid extraction. Moreover, SFE minimized sample handling, reduced the consumption of harmful solvents and provided conditions suitable for selective extractions of bile acids from bovine bile raw materials.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chiral-enantiomeric separation ; Amylose-based chiral phases ; Melatonin analogues ; Tetrahydronaphthalenes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Analytical HPLC methods using derivatized amylose chiral stationary phases were developed for the resolution of enantiomers of methoxy an ethyl tetrahydronaphthalenic derivatives, new agonist and antagonist ligands for melatonin receptors. Separation was by normal phase methodology with a mobile phase ofn-hexane-alcohol (methanol, ethanol, 1-propanol or 2-propanol) in various proportions, and a silica-based, amylose tris-(S)-1-phenylethylcarbamate (Chiralpak AS), or tris-3,5-dimethylphenylcarbamate (Chiralpak AD). The mobile phase and the chiral stationary phase were optimized for best resolution. The effects of concentration of alcohol, various aliphatic alcohols in the mobile phase were studied. The effects of substitution were analysed. Baseline separation (Rs〉1.5) was easily obtained in man cases.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...