ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Column liquid chromatography  (693)
  • Springer  (693)
  • American Chemical Society
  • 1995-1999  (344)
  • 1985-1989  (349)
Collection
Keywords
Publisher
Years
Year
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Reversed-phase ; Codeine phosphate drug substance ; Opium alkaloids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid procedure for the evaluation of codeine phosphate drug substance derived from poppy straw or opium concentrate is described. The gradient HPLC procedure employs a pH 2.5 phosphate buffer, methanol and acetonitrile mobile phase at 40°C and a μBondapak C-18 column. Eight opium alkaloids, including the four major alkaloids, are separated from each other. The paper describes details of the assay procedure and presents data documenting the linearity, specificity, precision, and sensitivity of the method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; External variance determinations ; Column and system compatibility ; Microbore and fast LC
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The demand for faster, more economic and convenient high-efficiency LC analyses has led to the development of microbore and fast columns. However, to utilize their benefits, the low column dispersions produced by these new technologies necessitate low external variances in the total system. This paper describes the determination of the external variance of microbore, fast and conventional LC systems by a column method. Compatibility with the relevant column technologies is evaluated by a method involving the comparison of the external and column dispersions. Direct comparison of chromatograms of an 8-component mixture, on a set of columns of various diameters and lengths, shows the relative speed, economy and sensitivity obtainable in practice. The problem of reduced sample loadability is considered and the practical solution of peak compression illustrated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Retention prediction system ; UV multichannel detector ; Polycyclic aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The retention prediction system assisted by a micro-computer coupled with an UV multichannel detector has been investigated in the separation of polycyclic aromatic hydrocarbons. The method offered very precise identification of components in NBS-SRM-1647 sample without any standard reference substances. It has been proven that the system makes very precise, non-pollutive and convenient environmental analysis possible.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 20 (1985), S. 313-322 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Tetracyclines antibiotics ; Quantitation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of high-performance liquid chromatography (HPLC) for the identification and determination of tetracycline antibiotics is reviewed. HPLC chromatograms provide fast identification by retention time, tR, and precise quantitation by measurement of peak height or peak area. For separation of tetracycline compounds, most HPLC methods use reversed-phase C18 or C8 columns and UV detection. The HPLC solvent system should have a pH of about 6 to prevent steric changes in the tetracycline molecule. For accurate quantitation it is necessary to avoid tailing and this is accomplished by adding a zwitter ion to the solvent system. Methanol and acetonitrile are frequently used as organic modifiers in these solvent systems. In a single analysis, HPLC methods can be used to separate as many as nine or ten commercially used tetracycline compounds and to determine four to five tetracyclines in commercial tetracycline preparations or in biological fluids.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Resolution of optical isomers ; Chiral column ; Pyrethroids ; Fenvalerate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The separation of the optical isomers of fenvalerate [cyano(3-phenoxyphenyl)methyl 2-(4-chlorophenyl)-3-methylbutyrate] has been carried out by high-performance liquid chromatography (HPLC) on a chiral column with (R)-N-3,5-dinitrobenzoyl-phenyl-glycine (DNBPG) covalently bonded on aminopropyl silica and eluted with mixtures of methanol, 2-propanol, and hexane. The system was applied to the analysis of Pydrin®, an emulsifiable concentrate formulation of fenvalerate, and to the residue analysis of fenvalerate in milk samples. For the analysis of Pydrin® the only requirement was the proper dilution of Pydrin® with hexane. For the analysis of residues in milk, fenvalerate was extracted with hexane after precipitating the milk proteins with acetonitrile and removing the precipitate by filtration; the hexane extract was concentrated to small volume and filtered before being analyzed by HPLC.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 20 (1985), S. 487-494 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Size-exclusion chromatography ; Controlled-porosity glasses ; Boron-enriched glass surface ; Adsorptive properties
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Controlled-porosity glasses (CPG) are sieves for macromoleculars, very widely applied in chromatographic columns for the separation of polymers and biopolymers by means of size-exclusion chromatography (SEC) and affinity chromatography. This paper deals with the influence of the thermal treatment of CPG on the elution of polymers in SEC columns. The problem is examined for a few mobile phases and for glasses having different porosities. Additionally, the SEC results obtained are compared with the adsorption properties of the glases investigated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Electrochemical detection ; Cysteinyldopamine ; Tyrosinase ; Autoxidation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary 5-S-Cysteinyldopamine, a new metabolite of dopamine, was determined in urine by high-performance liquid chromatography with electrochemical detection. The catechol was detected in 14 of 21 melanoma patients and 7 of 21 normal subjects; the highest values were 657 μg/day for melanoma patients and 44 μg/day for normal subjects. These results suggest that the cysteine conjugate may arise from autoxidation of dopamine but tyrosinase may also participate in the oxidation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 21 (1986), S. 136-142 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chemical reaction detector ; Carbamate insecticides ; Quantitation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary For the determination of trace amounts of carbamate insecticides in vegetables the combination of liquid chromatography with post column chemical derivatization (chemical reaction detector) is used. In a two step reaction detector the carbamates are firstly saponified in 0.01 M sodium hydroxide at 80°C with a reaction time of 30sec. To this mixture OPA reagent is added to detect the methylamine generated in the saponification. Optimization strategies for this reaction are demonstrated. At a temperature of 80 °C a reaction time of 80 sec is sufficient for quantitative transformation of the methylamine. The peak dispersion can be reduced and hence the detection limit improved by decreasing the diameter of the tubes and by diminishing dilution through the addition of reagent. A 1∶24 ratio of reagent to column (reactor) effluent is possible with cyclone-type mixers. The quantitation of carbamates in different vegetables is demonstrated. The detection limit is 20ppb at a signal to noise ratio of 10∶1.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 21 (1986), S. 205-213 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chiral phases ; Optimization of separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation and properties of chiral bonded phases with amino acid groups are described. These phases were used in non-polar eluents and in aqueous systems in the presence of Cu2+ ions in the ligand-exchange mode. The optimization of chiral resolution is demonstrated for both cases. With non-polar eluents similarity between bonded groups and solutes is required. The elution could be accelerated by non-protonic moderators. Ligand-exchange separation is influenced by the copper content of the eluent and the stationary phase, the organic moderator concentration, the pH and ionic strength of the buffer and by the temperature. Structural requirements of both the bonded groups and of the solutes for chiral separation are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Reversed-phase capacity factors ; Cavity term ; Molar volumes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Reversed-phase liquid chromatographic capacity factors are well correlated by an equation of the form: $$logk' = (logk')_0 + mV/100 + s\pi ^* + b\beta + a\alpha $$ wheremV/100 measures the cavity term and π*, β, and α are the solvatochromic parameters that measure solute dipolarity/polarizability, hydrogen bond acceptor basicity, and hydrogen bond donor acidity respectively. Liquid molar volume (molecular weight divided by liquid density at 20°C) $$\bar V$$ , and computer-calculated intrinsic (van der Waals) molecular volume, $$\underset{\raise0.3em\hbox{$\smash{\scriptscriptstyle-}$}}{V} _I $$ , are compared as measures of the cavity term in a number of correlations. $$\underset{\raise0.3em\hbox{$\smash{\scriptscriptstyle-}$}}{V} _I $$ leads to more precise correlations as well as to a “cleaner” dissection of the multiple solute/solvent interactions. The opposing exoergic effect of solvent donor/solute acceptor hydrogen bonding, and endoergic cavity term are the main factors influencing HPLC capacity factors.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 22 (1986), S. 40-42 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Pyridate ; CL-9673 ; Reversed phase
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The application of a simple reversed-phase, HPLC-UV method for the determination of the contact herbicide pyridate and its main metabolite 3-phenyl-4-hydroxy-6-chloropyridazine-known as CL-9673-in green cereals, grains and straw is described. The method is based on a simple extraction, separation of pyridate from its metabolite, hydrolysis of pyridate to CL-9673, high-performance liquid chromatographic separation of CL-9673 in both fractions using only one reversed phase column and UV-detection. The method is sensitive down to 3 ngg−1 CL-9673 in green plants and grain and 5ngg−1 in straw. In the range 0.05–1.0mgkg−1 recoveries are between 73.7% and 109% from green plants, between 77.7% and 102% from grains and between 77.3% and 87.5% from straw.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Betablocker drugs ; Lipophilicity ; Capacity factors ; Distribution coefficients
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The reverse-phase, high-pressure liquid chromatographic capacity factors (k') of a series of 18 betablocking agents were determined in order to establish correlations with their distribution coefficient values (D), obtained from four bibliographic sources. Under the three pH conditions studied (3.5, 6.2 and 7.5) statistically significant linear correlations (p〈 0.002) between log k' and log D values were obtained for the four series studied. In this series it is concluded that the k' factor is a useful and reliable relative lipophilicity parameter.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 22 (1986), S. 81-87 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Recycle chromatography ; Pressure dependence ; Capacity factor
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary It was found experimentally that the potential for routine, rapid high-efficiency separations by alternate column, recycle, reversed-phase chromatography is limited by the increase of capacity factors with pressure.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Metalloporphyrins ; 5,10,15,20-Tetraphenylporphine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The Co(II), Ni(II), Fe(III) and V(IV) complexes of tetraphenylporphine (TPP) can be eluted at short retention times from a LiChrosorb RP-18 column with pure ethanol. However, both Mn(III) and Co(III) complexes of metal TPP chloride type are so strongly retained on the column that they cannot be eluted. While the retention of other metal teraphenylporphine complexes was not affected, that of the metal(III) complexes of the TPP chloride type especially MnTPPCl and CoTPPCl, decreases dramatically with an increase in the concentration of NH4Cl added into the mobile phase; a linear relationship between logk' and log[NH4Cl], with the slope of about−1, has been observed for these two metal(III) complexes in the NH4Cl concentration range from 2.5×10−4 to 1.3×10−2 mol/l. Thus, the specific control of the retention of the metal(III) complexes is enabled by conditioning the NH4Cl content of the mobile phase, and the chromatographic separation is demonstrated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 22 (1986), S. 55-58 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; 1-Octanol/water partition coefficient ; Cellulose acetate ; Reverse osmosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The adsorption properties of esters, aldehydes, ethers and amides on cellulose acetate, which is commonly used as a reverse osmosis membrane material, in an aqueous solution system were measured by high-performance liquid chromatography. The adsorption property was characterized with the specific retention volume. For a noncyclic homologous series the logarithm of the specific retention volume was linearly correlated with the logarithm of the partition coefficient between 1-octanol and water. The fact that the slopes of these regression lines are almost identical confirms that the dominant effect on adsorption is the hydrophobic interaction between cellulose acetate and the solute molecule. The intercept represents the effect of the polar groups on adsorption. The effect of the polar group decreases as follows: ―C(O)O―, ―CO―, HCON〈 〉 CH3CON〈 〉 ―OH, ―O―.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Dihydroartemisine ; Interconversion equilibrium ; Multiple-peaks
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The interconversion between the α- and β-isomers and the multiple-peaks of dihydroartemisinine (dihydroqinghaosu) were investigated in reversed-phase, highperformance liquid chromatography. A convenient method using the Gaussian distribution function instead of the Schmidt graphical method for the theoretical calculation of the “diffuse” probability curves versus the fraction of the dead time on column as β form was introduced. Based on the theoretical probability curves and the experimental multiple-peak chomatograms, the effects of temperature and flow velocity on the accuracy and precision of analysis of dihydroartemisinine are indicated and the activation energy of the interconversion between α- and β-isomers of dihydroartemisinine is estimated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Nucleotides ; Mytilus edulis ; Smooth muscle
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the analysis of the 5′ mono-, di- and triphosphates of adenosine, guanosine, uridine and cytidine, as well as uridinediphosphate-glucose and cyclic AMP. Separation is achieved by reversed-phase ion-pair chromatography with linear gradient elution. Application of this method to the analysis of nucleotides in smooth molluscan muscles is described, including the determination of cAMP-levels and the calculation of energy charges for all of the four nucleotide systems.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Porphyrin ; Metalloporphyrin ; Hematoporphyrin IX
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The feasibility of reversed-phase high-performance liquid chromatography for the separation of metal complexes of hematoporphyrin IX (Hp) is described. The retention order, Zn-complex〈Hp (free acid)〈 Ni-complex〈Cu-complex, is regular on an octadecylbonded stationary phase with different compositions of an aqueous methanol mobile phase. These four compounds can be successfully separated within about 8 min on a LiChrosorb RP-18 column (250×4-mm i.d.) with a 85:15 (vol/vol) mixture of methanol and phosphate buffer (pH 3) at a flow rate of 1 ml/min.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 22 (1986), S. 157-159 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Flavonol aglycones ; Isocratic elution ; Wine phenolics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An HPLC isocratic elution procedure which allows the separation of flavonol aglycones in wine without interference from other phenolics of low molecular weight is described. The method has been applied to the separation, identification and quantitative estimation of flavonol aglycones in ether extracts of different Spanish wines (red and white table wines and Sherry finos). The results suggest that these determinations, associated with other analyses, would permit the chemical characterization of wines.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 796-802 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Steroids ; Rat tissue ; Purification by extraction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A high-performance liquid chromatographic method for analysis of steroids in the tissue of laboratory animals is described. A two-stage solid extraction procedure, utilizing Sep-pak C18 and graphitized carbon black, gives a purified product. Steroids in this extract were separated by multistep gradient elution with a reversedphase liquid chromatography system, using acetonitrilewater as solvent. Several columns with different geometry and phase loading were investigated. Optimum resolution was obtained with a medium covered and spherical particle. The applicability of this method was successfully demonstrated in the analysis of the testis and adrenal gland of rat.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 814-817 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Thin layer chromatography ; Ammonium tungstophosphate ; Aminoacids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The chromatographic behaviour of aminoacids on columns of silica coated with different percentages of ammonium tungstophosphate at several buffer phosphate concentrations is reported. The stationary phase shows a high selectivity towards aminobutyric acids and methyl derivatives of tryptophan due to the distance between the carboxylic group and the −NH 3 + group involved in the cation-exchange process and/or to the steric hindrance by a methyl substituent. A relationship between HPLC and HPTLC data has been verified and applied to the prediction of the separation of six aminoacids.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 934-938 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Calibration ; Confidence interval ; Limit of determination ; Limit of calibration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In HPLC calibration the expressions lowest calibration limit and determination limit are defined in statistical terms. The lowest calibration limit is the minimum mass in the measured series of calibration points. It is calculated from the confidence interval of the inverse of the calibration function as the lowest mass limit that may be differentiated from zero mass with a preset probability of error. If the calculated lowest calibration limit is lower than the actual data, points at lower concentration may be measured. The determination limit is the smallest concentration of an analysis that is differentiated from the concentration zero or an apparent blind value in the calibration curve with a given probability of error. Using two different UV-detectors (variable wavelength and photodiode-array) the lowest calibration limit is experimentally evaluated and compared with specific data for the detectors.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Pre-column derivatization ; Ultraviolet detector sensitivity ; Dihydroartemisinin ; Diacetyldihydrofluorescein
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of diacetyldihydrofluorescein (DADF) for derivatization of dihydroartemisinin (dihydroqinghaosu, DHQHS) is proposed. The reaction between DHQHS and this reagent in the presence of 4-dimethylaminopyridine (DMAP) and N,N′-dicyclohexylcarbodiimide (DCC) was complete in 8 hours at room temperature giving about 80 per cent theoretical yield. The derivative showed intense UV absorption, thus providing a sensitivity of 0.1 nanogram by UV detection after column separation. The influences of the ratio of the reagents, reaction temperature, chromatographic conditions and the extent of detection linearity were investigated. The reaction gave consistent results and chromatographic separation was not affected by an excess of the reagent or side products.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 395-400 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Photokinetic data ; Reaction mechanism ; (E)-1-phenylpropene
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A combined method of high-performance liquid chromatography and UV-absorption spectroscopy is described for use in dynamic systems. It provides a way of obtaining detailed mechanistic information as well as quantitative data (rate constants, quantum yields), even though neither mechanism nor photoproducts are known. The kinetic treatment of the photoreaction of (E)-1-phenylpropene was successful, showing a photo-isomerization and a parallel step. Information on this additional step is obtained by using HPLC to observe the changes in the concentrations of the reactants' selectivity. The necessity of process control is demonstrated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 419-422 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Fatty acid esters ; Particulate material in seawater
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method for the determination of fatty acids of the molecular weight range of propionic to erucic acid is reported. The acids are converted to either p-bromophenacyl-or p-phenylphenacylesters and the esters are separated by HPLC and detected by UV-absorption. Twentytwo esters, including saturated, monoolefinic and polyunsaturated ones were separated within one HPLC-run. The detection limit is about 5 pmol per fatty acid. The application of the method to particulate material is described.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Anion-exchange stationary phases ; Polymer coating ; Cross-linking
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary PHEB=POLY(2-hydroxy, 3N-ethylenediamino)butadiene has been synthesized. This unsaturated pre-polymer can be immobilized on different, preferably inorganic supports of suitable porosity such as silica or alumina by cross-linking. Weak anion-exchange phase are obtained. Such phases do not have the disadvantages of organic polymeric phases, regarding pressure stability and swelling by solvent influence. The ion-exchange capacity and the retentivity of IE-separations can deliberately be varied via the thickness of the cross-linked polymer layer. Alumina can also be coated with PHEB applying the same cross-linking procedure. Such phases exhibit an exceptional chemical stability even when operated with mobile phases at very high pH-values. Separations of excellent selectivity are achieved for inorganic anions, as well as with mixtures of aliphatic and aromatic free acids also including hydroxy- (mono- or poly)carboxylic acids.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Reversed-phase systems ; Stationary phase-solute interactions ; Polycyclic aromatics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Capacity factors of peropyrene-type polycyclic aromatic hydrocarbons were measured using 15 different liquid chromatographic reversed phase systems. On the basis of the retention data the electric interaction indices have been calculated. Application of these indices for structure-retention studies on peropyrene-type polycyclic aromatic hydrocarbons is demonstrated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 25 (1988), S. 31-36 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Radioactivity detector ; Solid scintillator ; Fibre-packed flow cells
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new type of flow-cell radiation detector for use in liquid chromatography which is packed with aligned scintillator fibers is described. A primary advantage of the fiber packed cell is that light generated by the scintillator is absorbed to a much less extent by the fibers than by the powder scintillator used in conventional flow cells. A detection efficiency of 55% has been obtained for carbon-14 using 0.1-mm diameter hand-pulled glass fibers. Computer modeling has shown that even better results can be obtained by using smaller and more uniform diameter fibers which will allow better packing. The fiber cell also demonstrates back pressures which are a factor of 50 less than the conventional cell and much less susceptibility to absorption of compounds because of its lower surface area.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 25 (1988), S. 854-860 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polystyrene ; Gradient elution ; Turbidimetry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Polystyrene samples of narrow molecular-weight distribution have been eluted according to their molecular weight from columns packed with bare silica Si50, phenyl, or C18 bonded phase by gradients of methanol and tetrahydrofuran (THF) or ofiso-octane and THF. Among the six combinations investigated,iso-octane/THF with a silica column formed a proper normal-phase system whereas methanol/THF with a C18 column formed a proper reversed-phase system. The combinations of C18 column andiso-octane/THF or of Si50 column and methanol/THF gradient did not correspond to the approved polarity rules in high-performance liquid chromatography but were nevertheless effective in separating polystyrene mixtures by molecular weight. Methanol andiso-octane are nonsolvents for polystyrene whereas THF is a solvent. The solubility of polystyrene as a function of molecular weight and concentration was determined by means of turbidimetric titration of solutions in THF with the nonsolvents used in the gradients. The solubility and elution characteristics were almost identical on C18 columns or in methanol/THF combinations. The elution from phenyl bonded phase and Si50 columns usingiso-octane/THF gradients required more THF than the solubility experiments. Information is also given on the occurrence of multimodal elution patterns.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polycyclic aromatic compounds ; Alkylated PAC ; Retention characteristics ; Normal phase
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Retention characteristics of series of polymethyl and mono-n-alkyl derivatives of benzene and pyrene, and also of parent polycyclic aromatic hydrocarbons (PAH), were studied using silica and aminopropyl- and cyanopropyl-modified silica. Differences in the selectivities for the studied compound groups were found between the three phases. Deviations from linear behaviour in plots of log (k′)vs. carbon number were observed for the methyl series. These are explained in terms of differences in π-electron delocalisation within the aromatic ring systems. Further, the effect of methyl substitution on selectivity decreased with an increasing number of aromatic rings. Results were obtained which indicated that the primary adsorption site in a cyano column used in normal phase mode, at least for PAH molecules, is the cyano group.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 25 (1988), S. 43-50 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Reversed phase ; Void volume ; Adsorption isotherms
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In reversed-phase liquid chromatography with n-alkyl bonded silica, the dead volume (V0) of the column is theoretically indeterminate owing to adsorption of organic modifier on n-alkyl chains and of water on silanol groups. With binary mobile phases, retention volumes of the mobile phase components and of their deuterated species are relaeed to the adsorption isotherms and V0 by equations which can be solved with some assumptions on the adsorbed layer composition. Methanol-water and acetonitrile-water systems are studied. As the experimental excess isotherm shows a linear part in the concentration range 50–80% in organic modifier, the hypothesis of an adsorbed layer of constant composition in this range is possible. When increasing the water content of the mobile phase, adsorption of water occurs up to saturation of silanol groups. Then the assumption of a constant water content for a mobile phase having more than 50% of water is applied. With the hypothesis of a constant adsorbed content of organic modifier when the eluent has more than 80% of organic modifier, V0 and the absolute isotherms are calculated over the entire range of mobile phase composition. Experimental retention behavior of the mobile phase components are totally explained by these V0 determinations. The retention times of commonly used V0 markers are compared with V0 values. It is shown that, when buffering the eluent, no visible effect on the distribution equilibrium is observed, so that injection of concentrated potassium nitrate is a convenient method to measure V0. With a few solutes with are UV detectable it is possible to measure V0 whatever the mobile phase composition in methanol-water and acetonitrile-water systems.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Stationary phase solubility parameters ; Cyano-silica ; Amino-silica ; Diol-silica
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Extended solubility parameters have been determined for aminopropyl, cyanopropyl and 1,2-dihydroxypropyl propyl ether (diol) normal bonded-phase HPLC columns. Parameters were calculated from both the retention data of solutes (partition model) and empirically determined solvent strengths (adsorption-displacement model). The use of solvent strengths to calculate solubility parameters for these silica-based bonded stationary phases appears to be superior, since this technique avoids many of the problems that arise from their inherent heterogeneity. Normalized solubility parameters were also used to position these columns on a stationary phase selectivity triangle. The amino and cyano phases appear in regions of the tringle expected based on the properties of the pure liquids, but an ether linkage in the diol apparently neutralizes some of the acidity expected from this phase.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Macrolide antibiotic azithromycin ; Intermediates of azithromycin ; Optimization of separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary HPLC is the most convenient method for the assay of the azithromycin (10-dihydro-10-deoxo-11-methyl-11-azaerythromycin A), a semisynthetic macrolide antibiotic and its reaction intermediates. Data concerning the effects of pH, temperature and column type are presented. The analytical procedures enabling the reliable assay of azithromycin and its intermediates, as well as other impurities are defined. Use of a reversed-phase octadecyl column, a pH of 9.3–9.5, and isocratic mode at ambient temperature are the best conditions of analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Metabolic disorders ; Xanthine and 2,8-dihydroxyadenine ; Urine analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary 2,8-Dihydroxyadeninuria and xanthinuria are inborn enzyme disorders which must be under lifelong therapeutic control. Quantitative determination of 2,8-DHA and xanthine using reversed phase HPLC was performed. A new application for the separation of purines shortens analysis-time. Examples of the determination of 2,8-DHA and xanthine before and under certain therapies are shown. Long term monitoring of the patients offers the possibility of a reliable prophylaxis against stone recurrence.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Indirect detection of non-electrolytes ; Simulation of induced peaks ; RP systems
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Induced peaks observed in indirect detection of nonelectrolytes in high-performance liquid chromatography are simulated. The equation representing the signal intensity of the induced peaks is derived, and it is verified by the experimental results. The peak area is proportional to (K b ′ +1) k a ′ /| a ′ —k b ′ |, where k a ′ ad k b ′ are the capacity factors of the visualization agent and the analyte, respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 25 (1988), S. 162-166 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ion chromatography ; Analysis of metal ions ; Post column derivatisation ; Amperometric detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method for determination of metal ions subsequent to separation by ion chromatography has previously been developed. The method is based on Indirect Amperometric Detection whereby the decrease in the oxidation current, due to a dithiocarbamate ligand added post column, is monitored. Upon elution from the chromatographic column the metal ions are complexed by the ligand. As the complexes formed are electroinactive at the applied potential, the background current decreases according to the metal ion concentration. The method developed in this work involves addition to the reagent of Zn(II) as a auxiliary metal ion to displace the analyte metals from the chromatographic eluent ligand complexes after separation. Sodium bis(2-hydroxy-ethyl) dithiocarbamate was used as the postcolumn derivatising reagent. The addition of Zn(II) to the reagent causes some unforeseen behaviour in the chromatographic system.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 25 (1988), S. 199-204 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Column switching ; Catecholamines ; Urine ; Serum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary We developed an automated, two-column HPLC-method that can be used routinely to quantify the catecholamines norepinephrine and epinephrine in body fluids. The method is based on a new, laboratory-prepared SEC-HPAC column material, on the application of a microprocessor-controlled column-switching technique, and on the use of an integrated reaction system for postcolumn derivatization and trihydroxyindol-fluorescence monitoring. It allows the direct injection (upto 500 μl) of an appropriate biological fluid and distinguishes on its integrated sample-processing mode, its practicability, its chemoselectivity and-specivity, its detection limit (2 pg), its within- and between-run precision and its speed of analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Pheophytinatonicke(II) ; Chlorophyll ; Pheophytin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary HPLC determination of pheophytinatonicke(II) (Pheo-Ni) prepared by the replacement of magnesium(II) in chlorophyll with nicke(II) is described. The good separation of PheoNi was obtained by using chemically bonded C18 as the stationary phase and acetone-methanol (50∶50, vol/vol) as the mobile phase. Conventional spectrophotometric method was also used for the determination of PheoNi. For the synthetic samples prepared by mixing (pheophytinato a) nicke(II) [(Pheo-a) Ni] and (pheophytinato b) nicke(II) [(Pheo-b) Ni], analytical values obtained by the spectrophotometric method were very high compared to those obtained by HPLC. In the proposed HPLC method, (Pheo-a) Ni and (Pheo-b). Ni could be determined in the concentration range of 0.028–30μg/ml and 0.038–30μg/ml with relative standard deviations (n=10) of 3.1% and 0.8%, respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Flavonoid compounds ; Structure-retention relationships ; Reversed-phase systems
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Reversed-phase HPLC retention behaviour of different flavonoid compounds in different columns and with a range of methanol-buffer eluents was examined. Repeatibility and reproducibility of logk′ and Δlogk′ values were analyzed. Sharp group contributions, expressed as Δlogk′, were observed. These did not depend significantly on acid modifier type, column packing characteristics (C8 and C18) and dimensions (5,7 and 10μm) or the percentage of methanol in the mobile phase. A list of twelve group contributions is presented which is in agreement with literature data.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 25 (1988), S. 443-446 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Large scale separations ; Dissolution of silica ; Metallic contaminants
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Possible contamination of purified product by the silica matrix is of considerable importance when considering process scale high-performance liquid chromatography (HPLC) as a separation methodology. The stability of silica supports in normal phase, reversed phase and affinity chromatography modes has been examined with organic solvents and water. Both inorganic and organic components were found, contributed by the support, and the chromatographic and distillation equipment. In all cases, based on assumed values of production, they were found to contribute less than 0.01% of impurities. In critical cases crystallisation or dialysis may be considered as a last stage of purification, with re-chromatography to maximise yields.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Fast atom bombardment mass spectrometry ; Nonionic detergents
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Microcolumn liquid chromatography (LC) combined with fast-atom-bombardment mass spectrometry (FABMS) was applied to the analysis of nonionic detergents. The porous silver filter attached to the top of the capillary fused-silica tubing worked as the interface for coupling of micro LC and FABMS.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 25 (1988), S. 577-581 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Process scale ; Examples of separations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The flexibility of process scale high performance liquid chromatography is demonstrated by three examples of reversed-phase separations (a) a standard purification (b) isolation of trace compounds, and (c) recovery from crystallisation mother liquors. It was shown that a material, thought to be acceptably pure, contained a toxic impurity, and a remaining impurity, a previously unseen component of potential therapeutic interest. Favourable cost data were indicated for example (3).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Benzidine+diaminodiphenyl methane derivatives ; Preconcentration from urine ; UV and electrochemical detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary For the title compounds 4,4′-DADPM, MOCA, 3,3′-DCB, 4-ADP and 4-ADPA listing on the EPA priority pollutant list, an analytical practicable, reliable, reproducible and sensitive procedure is required. Therefore a new method has been developed for the routine determination of these toxic aromatic amines in urine at the ppb level. The quantitative determination of amines is a suitable procedure of occupationally exposed persons. Urine sample preparation is done using simple liquid-liquid extraction followed by a precolumn enrichment (PRP1-material; Hamilton). Breakthrough measurements were done using an enrichment column packed with PRP1 material. The capacities of the studied amines ranged from 21.9mg/g to 96.6mg/g, while influent concentrations differed from 28.3mg/l to 332.0mg/l. The advantages of electrochemical detection regarding to selectivity and sensitivity are clearly indicated in this paper. Separation has been achieved applying reversed-phase-high-performance-liquid chromatography (LiChrosorb RP 18/5μm) followed by electrochemical or UV-detection. The detection limits employing an electrochemical detector at a potential of 1 V range from 2.2ng to 12.1ng. UV detection at 254 nm and 280 nm is about 10–100 times less sensitive. Recoveries from spiked water samples at the 5ppb levels were 75% to 96% respectively. The standard deviation of the developed procedure varies from 5.3% to 14%. Day-to-day repeatability is good.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    ISSN: 1612-1112
    Keywords: Thin layer chromatography ; Column liquid chromatography ; 21H, 23H-Porphine ; Metalloporphyrin complexes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The chromatographic mobility of 21H, 23H-porphine and its Ni(II), Cu(II), Zn(II) and Pd(II) complexes were investigated by high-performance thin-layer chromatography on an octadecyl-bonded, silica gel plate with various polar organic solvents including alcohols, acetonitrile, dimethylsulfoxide and propylenecarbonate. The mobility generally decreases according to the central metal ion of the complex as follows: Zn(II)〉(free porphine)〉Ni(II)〉Pd(II)〉Cu(II). Methanol is a good choice of solvent for the separation of these metal porphine complexes. Successful separation of porphine and the four metal complexes is accomplished within 13 min on a LiChrosorb RP-18 column with methanol eluent.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 25 (1988), S. 717-720 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Reversed-phase chromtography ; Antifungla agent ; Pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A high-performance liqid chromatographic method is reported for the measurement of miconazole in systemic, fungal infectious patients. Pharmacokinetic data are presented for a single patient receiving miconazole therapy. Sample preparation involves protein precipitation by acetonitrile (1:1, vol/vol). Analyses are carried out on a reversed-phae chromatographic system using octadecylsilane stationary phase: a mobile phase consisting of 0.05 M acetate buffer (pH 7.4)acetonitrile (20:80, vol/vol) is used to elaute miconazole is quantified on the basis of ultraviolet absorption at 220 nm. The precision of the method ranged from 3.21% at 0.5 mg/L to 0.85% at 2.0 mg/L. The limit of quantification was established as 0.1 mg/L. Interference from other drugs that are co-adimistered such as amphotericin B, 5-fluorocytosine of ketoconazole and most other comonly encountered drugs was not observed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Mobile phase composition and column temperature ; Retention prediction ; Polycyclic aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The relationship between the logarithmic capacity factor measured in reversed-phase liquid chromatography and the operating conditions including the mobile phase composition and the column temperature is investigated. The strategy described herein can offer the possibility to predict the retention of polycyclic aromatic hydrocarbons without any experiments and standard materials, by utilizing equations describing the relationships between retention, temperature, mobile phase composition and physicochemical properties of the solutes previously stored in the program of the microcomputer-assisted retention prediction system. This concept is one of the most promising techniques for the optimization of the separation conditions in reversed-phase liquid chromatography.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Fractional factorial experimental designs ; Ruggedness test ; Method validation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Recently much attention has been directed to the validation of analytical methods. The level of validation will depend on the method application. If a method is developed for general use, for instance by different analysts, instruments or laboratories, then the effect of these changes need evaluation. This is normally referred to as ruggedness testing, where the limitations of the method to changes in the specified conditions are examined. This paper examines the use of Plackett-Burman fractional factorial experiment designs for ruggedness testing in high performance liquid chromatography (HPLC). The ability of these designs to identify confounding effects is applied to the stability indicating analysis of Salbutamol and its major degradation product, AH4045. The results show that confounding effects, proving extremely pertinent to HPLC, can be identified. The assay proved rugged to most tested changes although not to the use of column packing material from different manufacturers.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 22 (1986), S. 231-234 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Post-column reactor ; Crosheted PTFE construction ; Photochemical reaction detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Construction of crocheted photochemical reactors for use in high performance liquid chromatography is described. The design of these reactors is optimal for low intensity light sources because of their cylindrical configuration. Band broadening is minimized by the use of tightly crocheted narrow bore tubing and fittings modified to reduce dead volume. These reactors are suitable for most post-column photochemical reactions with the additional possibility of serving as mixing/delay coils, deoxygenation devices for electrochemical detectors, and as low dispersion detector cells for chemiluminesckent reactions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 31-32 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Gonadal steroids ; Epimers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Chromatographic separation of biologically active epimeric steroids was carried out using a combination of normal and reversed phases. Testosterone (17β-OH) was separated from its 17α-OH epimer epitestosterone using a normal phase silica column whereas their reduced 5α-metabolites were separated on a reversed phase system. The separation of other gonadal steroids including the epimers 20α- and 20β-hydroxypregn-4-en-3-one is also discussed. The technique is particularly useful for separating mixtures of naturally occurring steroid epimers prior to radioimmunoassay.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ammonium acetate buffer eluent ; Chlorophylls and degradation products ; Marine phytoplankton
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An RP-HPLC procedure which separates chlorophylls and their degradation products is described. By employing an amonium acetate buffered mobile phase and a linear gradient elution, complex mixtures of chloroand phaeopigments are separated in less than 30 minutes. The method has been applied to the control of chlorophyll enzymatic degradation in cultures of two algal species, and has also been successfully used in the analysis of algal xanthophylls.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Alkyl-bonded phases ; Retention behaviour ; Ligand density ; n-alkyl chain length
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two series of bonded phases were synthesized employing LiChrospher Si 100, 10 μm and n-alkyldimethylmonochlorosilanes as silanizing reagents. In series A the n-alkyl chain length, n, of the bonded phase was varied between 1 and 20 at a constant ligand density of 3.5±0.2μmol·m−2. In series B the ligand density, d, was gradually changed from 0 to 4.1μmol·m−2 on the C1, C4, C6, C8 and C18 bonded phases, respectively. The capacity factors of benzoic acid esters and anilines as solutes were found to increase linearly with the n-alkyl chain length of packings at constant eluent composition (series A) up to a so-called critical chain length, ncrit, where the capacity factor remained constant. ncrit was in the range from 11 to 14. The same pattern was observed when plotting the solute capacity factor against the ligand density of the packing at constant n and constant eluent composition (series B). The critical ligand density, αcrit, varied between 2.3 and 3.2 μmol·m−2 depending on n and the solute. Furthermore, solute retention was slightly higher on RP packings with an even number of carbon atoms in the alkyl chain than on those with an odd number. These findings are consistent with the results of Berendsen and de Galan (J. Chromatogr., 196, 21 (1980)), Dill (J. Phys. Chem., 91, 1980 (1987)) and Simpson and Lau (to be published). The observed phenomena reflect the dynamic structure of RP silicas which are related to the mobility of solvated n-alkyl chains. Due to the lack of a precise conformational analysis of the surface of RP silicas, a semiquantitative model was applied to interprete the described dependencies.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Behaviour of metal complexes ; Solvophobic theory
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The chromatographic behaviour of Cu(II), Fe(II), Ni(II) and Co(II) complexes with 4-(2-pyridylazo)resorcinol was studied. The experimental results were very sensitive even to less obvious operational parameters like the kind of the cation (sodium or ammonium) of the phosphate salt used as buffer. The puzzling pattern of the data obtained was interpreted in terms of the equations formulated by Horvath's ‘olvophobic” theory which correlates the capacity factors of the solutes with the surface tension of the mobile phase. A satisfactory rationalization of the data was obtained together with qualitative information on the stoichiometry and charge state of metal complexes. Useful suggestions about the direction to address the experimental work in order to obtain the best results was also obtained.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ligand Exchange ; Diethylenetriaminepentaacetic acid ; Transition metal ion separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Basic alumina-bonded diethylenetriaminepentaacetic acid (DTPA) has been utilized for the separation and preconcentration of some transition metal ions on the basis of ligand exchange. Breakthrough capacity and rate of sorption have been studied. The distribution coefficients of 16 transition metal ions have been determined in demineralized water, 0.01 M sodium citrate and in four different pH systems. On the basis of differences in Kd values some quantitative separations of metal ions have been achieved. The greater selectivity behaviour (higher Kd values) of the adsorbent for Pt(IV)and Cr(III) has been utilized for their preconcentration in the presence of other metal ions. The method has been employed for the recovery of Pt(IV) and Cr(III) from tapwater and sea-water samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Gel permeation chromatography ; Cheese peptides ; Amino acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The nitrogen fraction from cheese, soluble in phosphotungstic acid has been analyzed by gel permeation and high performance liquid chromatography. Elution profiles of this fraction on Sephadex G-10 show that there are no peptides of molecular weight higher than 700 daltons. Six fractions have been obtained. The first one has the peptides and some amino acids. Fractions II to VI contains mostly free amino acids. Fraction I has been separated into many peaks by HPLC. Six or seven of these peaks are presumed to correspond to peptides.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Small-bore packed columns ; Air pollutants ; PAH, nitro and oxy-PAH ; Aldehydes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation of small bore columns (1 mm i.d.) packed with reversed-phase materials is described. High efficiency (Hmin=2 dp), coupled with a small C term (0.005 sec) have been obtained so that high speed can be combined with sufficient resolution for the separation of complex organic mixtures. These columns have been used for the separation of air pollutants dispersed in different matrices (air, particulate matter and rain water). Practical applications include the determination of aldehydes in air and emission samples, PAHs, nitrated and oxygenated PAHs in dust sampled from the stack of an industrial emission or collected in a urban area and the analysis of organic components dissolved in rain water collected at a rural site. Specific detection of these pollutants has been achieved by connecting small bore columns to UV absorbance, voltammetric and fluorimetric detectors. Mass spectra of some specific components have been recorded using the off-line technique.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 825-828 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Gasoline ; Single-ring aromatic hydrocarbons ; Polycyclic aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This work reports a rapid and easy procedure for the analysis of the aromatic fraction in gasoline. No sample pretreatment is required, since the gasoline is diluted in methanol and directly injected into a liquid chromatograph. A spectrophotometer detector and a spectrofluorimeter detector are used in series. The procedure has been applied to a large number of Italian and European refined gasoline samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 27 (1989), S. 27-30 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; 1,ω-Di(alkoxy)-polysulphides ; Retention contributions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The reaction of S2Cl2 with alcohols yields products, the reversed-phase liquid chromatograms of which are similar to those of dialkyl-polysulphides RSnR, i.e., they represent homologous series. Four of the products were identified via GC-MS as 1,ω-di(alkoxy)-polysulphides having the general structure ROSnOR. Retention contributions of alkyl groups R and sulphur atoms in the −Sn — chain are not much different from values observed with polysulphides. The effect of oxygen, however, is only about −100 index units per O atom, while in dialkyl ethers values of −500 units have been reported.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 27 (1989), S. 5-14 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Retention behaviour ; Column parameters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Retention of small molecules on reversed phase or other hydrophobic stationary phases can be represented by k′ values of members of a homologous series at varying solvent compositions. The evaluation of simple linear relationships leads to the introduction of a set of four parameters that contain all the information about retention behaviour of this homologous series in the binary solvent system chosen. It is possible to extrapolate to a hypothetical non-hydrophobic molecule and a solvent, the polarity of which equals that of the stationary phase, to characterize the properties of the stationary phase — eluent system. In addition, a chromatographic method for determination of the phase ratio of the column is proposed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 109-111 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Normal and reverse phase ; Aldicarb ; Aldicarb sulfoxide ; Aldicarb sulfone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Aldicarb, aldicarb sulfoxide, and aldicarb sulfone were chromatographed on an octyl-silica bonded-phase column and on an unmodified silica column using acetonitrile/water mobile phases. The elution order of the analytes from the silica column was different from that using the octyl-silica bonded phase and allowed confirmation of residues of aldicarb sulfoxide in citrus nectar. Isocratic elution of the unmodified silica column allowed rapid sample throughput.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ligand-exchange chromatography ; Chiral bonded phase ; Racemate resolution ; Amino acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The resolution of racemates on chiral chemically bonded silica gel by high-performance ligand-exchange chromatography is described. The stationary phase was prepared by bonding (−) trans 1,2 cyclohexanediamine to silica gel through the coupling agent 3-glycidoxypropyl silane. The resolution of several α-amino acids and of compounds of pharmaceutical interest is reported.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Anion exchange separation ; Preparative separations ; Human chorionic gonadotropin hormone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A high-performance liquid chromatography (HPLC) method was developed for the purification of 50mg crude human chorionic gonadotropin (HCG) hormone sample in one chromatographic run on a 250×10 mm SERVA DEAE Poliol-Si-500 column. During the 60-minute linear gradient of 0.05 M sodium sulfate, 0.05 M sodium hydrogen sulfate and 0.05% (v/v) acetonitrile in buffer “B” complete separation was accomplished in 40 min. Identity and purity of the fractions were checked by SDS electrophoretic method. The eluted HCG fractions were dialyzed for 24 hours to remove the buffer salts and liophilized. The activity of the hormone did not decreased significantly during the purification procedure.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 99-101 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; High temperature open-tubular columns ; Solvent make-up ; Acetophenone oxidation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Acetophnone, a substance stable at room temperature, is readily oxidizes in a high temperature open tubular liquid chromatographic system by the residual oxygen in the mobile phase. The oxidation product is less UV absorptive and detection sensitivity decreases greatly. To prevent the oxidation, through degassing of the mobile phase is necessary.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Endotoxins ; Lipopolysaccharide ; Aminated poly(γ-methyl L-glutamate) ; Bovine serum albumin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the selective removal of endotoxins from various protein solutions using columns packed with aminated poly (γ-methyl L-glutamate) (PMLG-NH2) spheres. The PMLG-NH2 adsorbents showed a high adsorbing activity for endotoxins which had an ionic strength of μ=0.05–1.0 and pH 5.0–9.0. The endotoxin-adsorbing capacity per millitre of the wet adsorbent increased from 0.40 to 1.35 mg (E. coli O111: B4 LPS) at μ=0.2 and pH 7.0 while the aminogroup content of the adsorbent increased from 0.8 to 3.5 meq g−1. The PMLG-NH2-3.5 has an amino-group content of 3.5 meq g−1. This column packing selectively adsorbed endotoxins, without loss of the protein, from a γ-globulin or cytochromec solution which contained endotoxins at μ=0.05 and pH 7.0. On the other hand, when bovine serum albumin (BSA) was present in solution with endotoxins, both the endotoxins and the BSA were adsorbed by the column. The BSA-adsorbing activity increased with increasing amino-group content of the adsorbent. However, this undesirable adsorption was suppressed with increasing ionic strength of the buffer. As a result, when the packing which had an amino-group content of 1.5 meg g−1 was used in conditions of μ=0.2 and pH 7.0, the endotoxins were removed from a BSA-containing solution without affecting the recovery of the BSA.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 51-57 
    ISSN: 1612-1112
    Keywords: Column electrophoresis ; Column liquid chromatography ; Phenolic lignin degradation compounds ; Sugar degradation products ; Quantitative analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method for the quantitative analysis of phenolic lignin degradation products by capillary electrophoresis (CE) with on-column UV detection has been developed. The liquid biomass solutions contain low molecular hemicellulosic sugars and phenolic lignin degradation products with various degrees of polymerization. Special attention has been paid to the monomeric phenolic components of lignin degradation fragments, e.g. derivatives of phenolic acids, aldehydes, and alcohols. Uncoated fused silica capillaries and borate-phosphate buffer systems at moderate pH conditions were used in order to separate the compounds of interest. To provide validation of the method, the same samples were analyzed independently by HPLC using gradient elution on a RP-C18 column. As sugar degradation fragment, furan-2-carboxylic acid was detected.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 85-90 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Phenolic compounds ; Ion-pair solid phase extraction ; On-line trace enrichment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two packing materials, C18 and PLRP-S, are studied for on-line trace enrichment of phenolic compounds in water. Various precolumns of different internal diameter are also tested and the addition of an ion-pair reagent to increase retention and thus, breakthrough volumes of phenolic compounds, is studied. Best results are obtained when a PLRP-S precolumn is coupled on-line with a C18 analytical column and DAD detector. Addition of TBA considerably increases breakthrough volumes. In contrast, when a C18 precolumn is used, breakthrough volumes are lower and it is impossible to determine TCP and PCP, under the experimental conditions used, because of interference of other nonpolar compounds in the samples. The performance of the system is evaluated with river and tap water and the preconcentration of 10 ml of sample in a PLRP-S precolumn involves a linear range between 1 μg 1−1 and 20 μl−1 and limits of determination between 0.5 μg l−1 and 1 μg l−1 are obtained.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 631-637 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Trace analysis ; Pesticides in tap water ; Aromatic sulphonates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Methodology and instrumentation are described which allow chromatographic screening of water samples under substantially simplified conditions and at reduced cost. A single column is used to accomplish sample extraction, trace enrichment, and separation. The performance of such a system is demonstrated, and the results compared with conventionally used concepts.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Transchelation ; Zinc pyrithione and related compounds ; Antidandruff formulations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An analytical procedure has been developed for the determination of zinc pyrithione in antidandruff formulations. Zinc pyrithione was converted into a stable copper complex and then analysed by reversed-phase HPLC. The proposed method allows the separation of the analyte from related pyrithiones and therefore is able to verify the compliance of cosmetic preparations with current legislation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Benzodiazepines ; Solvent effects ; ACN clusters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two different methods were used to determine the separation factor α at different temperatures and the Gibbs-Helmholtz parameters (Δ(ΔH), Δ(ΔS)) of two adjacent benzodiazepines on a chromatogram were obtained from plots of lnα versus 1/T. We first studied each factor (fraction of water ϕ in the ACN/water mixture and column temperatureT), which controls the retention mechanism, and then we examined the simultaneous variation of all these factors. The changes in Δ(ΔH) and Δ(ΔS) in relation to a volume fraction of water ϕ in an ACN/water mixture were examined. In the ACN/water system, Δ(ΔH) was fairly constant in the acetonitrile region of ϕ≤0.52 and appears to be a roughly linear function of ϕ for ϕ≥0.52. In this system Δ(ΔS) is approximately a parabolic function of ϕ with an optimum at ϕ≅0.52. The retention mechanism of ten benzodiazepines was found to be significantly different in the methanol/water and ACN/water mixtures. The separation optimization of these ten benzodiazepines was then considered. A fraction of water of 0.43 in the ACN/water mixture and a column temperature of 44°C gave the most efficient separation conditions in the ACN/water mixture.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polyurethane degradation products ; 2,4- and 2,6-toluendiamine ; Urine analysis ; Breast implants
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A reversed-phase HPLC method has been developed for the urinary determination of mutagenic 2,4- and 2,6-toluendiamines. These amines are degradation products of polyurethane, a material used to cover textured silicone breast implants. FMOC-Cl was used as fluorescent derivatising agent in order to obtain a limit of detection of 15 ng/ml in urine. Pre-treatment of urine samples was by liquid/liquid extraction and urine specimens of patients after surgury were analysed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 41 (1995), S. 657-660 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polyphenols ; Flavonoids ; Phenolic acids and aldehydes ; Eucalyptus spp.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Standards of the polyphenols occurring in wood, bark and leaf extracts ofEucalyptus spp. (i.e. flavonoids and phenolic acids and aldehydes) have been analyzed by HPLC using reversed phase columns, gradient elution and diode-array detection. The conditions used are reported.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 657-661 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Reversed phases ; Polyencapsulated silica ; Polyacrylates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary By copolymerization of silica modified with vinyl groups and acrylic acid esters in suspension highly efficient, polymeric-encapsulated stationary-phases can be prepared. The suspending liquid has to be selected such that the monomers are at least partially adsorbed on the surface and the polymer formed does not precipitate. Under these conditions stationary phases capable of speedy mass transfer can be prepared, where the reduced plate heights are between 2 and 3. The silica surface shielding is optimized so that basic and acidic solutes elute with symmetrical peak.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chiral resolution of amino acids ; Pre-column derivatization ; Fluorescent chiral tagging reagents ; Stereochemical purity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Derivatization of amino acid enantiomers with fluorescent chiral Edman-type reagents, 4-(3-isothiocyanatopyrrolidin-1-yl)-7-nitro-2,1,3-benzoxadiazole [R(−)- and S(+)-NBD-PyNCS] and 4-(3-isothiocyanatopyrrolidin-1-yl)-7-(N,N-dimethylaminosulfonyl)-2,1,3-benzoxadiazole [R(−)-and S(+)-DBD-PyNCS], yields corresponding diastereomers separable by reversed-phase HPLC on normal achiral columns. The resolved diastereomers were detected fluorometrically at 530 nm with excitation at 490 nm for the NBD-PyNCS derivatives and at 560 nm with excitation at 450 nm for those derived from DBD-PyNCS reagents. This HPLC-derivatization method was used for evaluation of stereochemical purity for some synthetic commercial peptides. The enantioanalysis was reliable down to 0.05% racemization of the amino acid residues and a quantity of 100 μg peptide sample was usually enough for the analysis. Two acid hydrolysis methods, i.e. the standard procedure with constant-boiling hydrochloric acid (HCl) and a rapid vapor-phase procedure with HCl-trifluoroacetic acid (TFA) mixture, were compared. The later was found to be unsuitable owing to increased racemization of the amino acid residues during the hydrolysis. Judging from the results obtained for proline and leucine residues, most of the tested peptides including biologically active peptides, such as neurotensin, [d-Ala2,d-Leu5]-enkepharin and morphine tolerance peptide, possessed stereochemical purities higher than 98%. Influence of structural features of the peptides on the racemization of the amino acid residues was found to be significant.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Mass spectrometric detection ; Fast atom bombardment ionization ; Serum bile acid ; Rat bile
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In order to analyse bile acids in biological matrices, e.g. rat bile and human serum, high performance liquid chromatography (HPLC) was coupled to continuous-flow fast atom bombardment mass spectrometry (CFFAB-MS). A gradient elution system which had already proved to be well suited for the quantitative determination of conjugated bile acids in bile was modified to allow HPLC-CFFAB-MS-coupling. Due to the sensitivity of this coupling method it is possible to obtain more information about the biliary bile acid pattern and species-specific secondary bile acids. Furthermore, we were able to identify obviously unknown bile acid species in rat bile which most likely classify as mono-oxo and di-oxo-taurocholates (MW 513 Da, 511 Da) and mono-oxo-glycocholates (MW 463 Da). In the present study we show that using this system it is possible to determine both conjugated and unconjugated as well as sulfated bile acids, without time consuming group separation and derivatization, from rat bile and human serum. In addition, it is suggested that the method presented here should be considered for use in routine analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Fluorescence enhancement ; Bovine serum albumin ; Dansylamino acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The effects of acetonitrile and bovine serum albumin (BSA) concentrations on the signal intensity and retention behavior of dansylamino acids have been examined by using γ-cyclodextrin-bonded silica gel as the stationary phase in microcolumn liquid chromatography. Fluorescence intensities of dansylamino acids were enhanced by BSA as a mobile phase additive, e.g., detection limits of dansyl derivatives of L-Ala and L-Phe were improved by a factor of 12–18.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Micellar liquid phases ; Octanol-water partition coefficient ; Benzene and naphthalene derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary It is shown that the logarithm of the capacity factor (log k′) for fifteen benzene and naphthalene derivatives in micellar liquid chromatography with forty nine different mobile phases generally correlates better with the logarithm of the octanol-water partition coefficient (log Pow) than the capacity factor (k′). Optimum conditions are established to obtain the best linear correlations of log k′-log Pow.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Photolysis ; Electrochemical detection ; Drugs with chlorinated aromatic rings
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Pharmaceuticals containing a thiazide ring or chlorinated aromatic ring were investigated with respect to enhanced selectivity in determination. Oxidative electrochemical detection coupled with HPLC was used to study the influence of the pH of the mobile phase under conditions of photolysis. To cover a pH range 3.9–12, the employment of a polymer column stable in alkaline media was necessary. The method offers the great advantage of derivatization without chemicals at low operating potentials, thereby providing high selectivity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 296-302 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Structural isomer separation ; Cyclodextrin ; Polymers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Several β-cyclodextrin (CD)-bonded stationary phases for high performance liquid chromatography (HPLC) were prepared, based on silica beads coated with a poly(alkylamine), [poly(ethyleneimine)(PEI)]. In order to obtain stationary phases with a high content of CD and maximum accessibility of the CD cavity, the functionalization was carried out after the coating, using the mono-tosyl derivative of CD as the intermediate. The ability of these supports to separate ortho, meta and para isomers of some disubstituted benzene derivatives was examined. The contribution of the amino groups of the polymer and of the CD cavity to the separation process is discussed. The resolution is mainly based on the difference in the stability of the complexes of the various isomers with CD. The influence of the amount of CD on the height of the theoretical plate is also studied.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Reversed phase ; Polystyrene ; Pellicular ; Ultra high molecular mass
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Ultra high molecular mass (〉 7 million dalton) polystyrenes are prone to degradation in size exclusion chromatography. In gradient elution reversed phase HPLC they do not elute visibly on small particle size porous supports. However, large diameter C18 pellicular particles were successfully employed for reversed phase study of ultra high molecular mass (15 million dalton) polystyrenes without polymer degradation during elution. Although retention for the lower molecular mass polystyrenes was lower than on small diameter porous particles, the medium high molecular mass polystyrenes (0.5–1 million dalton) showed similar retention. The addition of small diameter porous particles in small quantities, to the large diameter pellicular particles, increased the amount of retention of the low molecular mass polystyrenes without affecting the higher molecular mass polystyrenes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Methyl ethyl ketone in urine ; Derivatization ; 3-Methyl-2-benzothiazolinone hydrazone ; Comparison with GC-MS
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A HPLC method for the determination of methyl ethyl ketone (MEK) in urine after derivatization with 3-methyl-2-benzothiazolinone hydrazone is proposed. The calibration curve for the ketone was linear, ranging between 0.23–10 mg/L, with a detection limit of 0.025 mg/L. The results were compared to those obtained by GC-MS, coupled to the headspace technique. MEK derivatization and the derivative purification processes were verified with respect to the main variables such as reaction temperature, reagent concentration, probable interferences and enrichment phase. The method is simple and reliable and shows a good sensitivity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 382-386 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Sulfonamides in foodstuffs ; Honey ; Milk ; Eggs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A procedure for the simultaneous determination of several sulfonamides in different foods, such as honey, milk and eggs is proposed. The analysis is carried out using reversed phase liquid chromatography with spectrophotometric detection. Optimization of the mobile phase led to good separation and a short analysis time when an initial isocratic step with a 3∶97 acetonitrile: water mixture was used for 5 minutes, followed by a linear gradient up to a 40∶60 mixture over 15 min. The proposed method is suitable for routine quality control analysis to ensure the absence of sulfonamides in foods. Recovery studies yielded good results for all food samples because there were no interferences from the matrices.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 411-416 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Particle beam LC/MS interface ; Capillary columns for LC ; Mycotoxins ; Peanut meal
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new method for the analysis of aflatoxins in food extracts, based on liquid chromatography/mass spectrometry interfacing, is presented. The chromatographic separation was performed with a reversed phase packed capillary column coupled with a modified particle beam interface capable of handling microliter per minute flow rates. This system allows higher overall sensitivity and easier operation procedures. The method has proved to be particularly suitable for the analysis of the toxins in very complex matrices. The specificity of electron impact ionization allowed positive identification of the aflatoxins with an excellent response linearity for accurate quantitation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Thin-layer chromatography ; Reversed phase ; 2-benzoylbenzoic acids ; Anionic and cationic counter ions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The 2-benzoylbenzoic acid series was investigated by reversed-phase, high-performance, thin-layer and column chromatography using various alkylammonium salts and di(2-ethylhexyl)orthophosphoric acid as polar associating reagents. The effects of the individual substituents on retention were quantified by Δlog k′ and ΔRM values. The compounds investigated differing in molecular structure (hydrophilic and hydrophobic substituents) commonly occurring groups in drugs and biologically active substances provide information on molecular interaction in these ion-pair systems. The combined effects on retention of organic modifier and ion-pair reagent concentration were investigated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Two-dimensional separation ; D- and L-amino acids ; Enantioseperation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A two-dimensional, column liquid chromatographic system is used for the determination of the D- and L-enantiomers of amino acids in biological samples. Separation of the amino acids is first on ion-exchange column by gradient elution with a sodium citratesodium chloride buffer. Enantioseparation is by subsequent injection of 3 μl heart-cuts of the individual amino acids onto a second column with a chiral crown ether stationary phase. Finally, fluorescence detection is after post-column labelling of the amino acids using ano-phthalaldehyde-2-mercaptoethanol reagent solution. The high separation power and selectivity of the system allow processing of complex samples with hardly any additional treatment and the determination of small quantities of D-amino acids in the presence of excess L-form. Applicability of the system is illustrated by the determination of D- and L-aspartate, serine, glutamate and alanine in various complex biological samples, such as protein hydrolysates, urine and biotechnological and food samples. Data are given on detectability, repeatability and linearity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ion pair LC ; Sweeteners, preservatives and antioxidants ; Food additive analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A paired-ion, reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of sweeteners (dulcin, saccharin-Na and acesulfame-K), preservatives (sodium dehydroacetate, sorbic acid, salicyclic acid, benzoic acid, succinic acid, methyl-para-hydroxybenzoic acid, ethylpara-hydroxybenzoic acid, n-propyl-para-hydroxybenzoic acid, isopropyl-para-hydroxybenzoic acid, n-butyl-para-hydroxybenzoic acid, and isobutyl-para-hydroxybenzoic acid), and antioxidants (3-tertiary-butyl-4-hydroxyanisole and tertiary-butyl-hydroquinone). A mobile phase of acetonitrile-50 mM aqueous α-hydroxy-isobutyric acid solution (pH 4.5) (2.2 ∶ 3.4 or 2.4 ∶ 3.6, v/v) containing 2.5 mM hexadecyltrimethylammonium bromide and a C18 column with a flow rate at 1.0 mL/min and detection at 233 nm were used. This method was found to be very reproducible with detection limits ranged from 0.15 to 3.00 μg. The retention factor (k) of each additive could be affected by concentrations of hexadecyltrimethylammonium bromide and α-hydroxyisobutyric acid, and pH and ratio of mobile phase. The presence of additives in some food samples was determined.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Limit of detection ; Precision ; Uncertainty prediction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The precision of integration over noisy instrumental output for quantitative analysis is studied. A probability theory is developed to predict the relative standard deviation (RSD) of integration results over an integration domain from one-point integation (peak height measurement) to entire area integration in HPLC. Common integration modes of horizontal zero line and oblique zero line are taken into account, but no peak overlap is assumed. The question of the analytical superiority of peak height measurement or integration for quantitation is answered. In the HPLC apparatus used, the minimum RSD of measurements is found in the integration domain of ca. ±0.5 σ for analytes [peaks are approximated by the Gaussian signal of width, σ (standard deviation)]. The RSD of integration measurements is also shown to depend on the stochastic properties of back-ground noise (uncorrelated noise and correlated 1/f type noise). The theoretical conclusion is verified by Monte Carlo simulation and HPLC experiments for some aromatic compounds.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ion-pair and GPC separations ; Amoxicillin oligomers ; β-Lactam ring polymers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Polymeric substances formed from concentrated sodium amoxicillin in an aqueous solution have been separated using two high-performance liquid chromatographic methods. We used a C18 reversed-phase column with tetrabutylammonium chloride as an ion-pairing agent with an acetonitrile gradient and a TSKgel G2500PWxl column with water as the solvent for gel permeation chromatography. The separated materials, ranging in size from the monomer to the tetramer, have been characterized by functional-group chemical analysis, while the identification of the piperazine-2,5-dione was done using a pure standard. A greater number of peaks which were also better defined were obtained using the ion-pair reversed-phase method, and open and closed beta-lactam ring polymer forms could be distinguished. Using the gel permeation method, only a few monomer, piperazine-2,5-dione, dimer, trimer and combined amoxicillin trimer and tetramer peaks were obtained with water, although those obtained were quite well defined. The data on the time-course of formation of the oligomers and the amoxicillin degradation product were virtually identical by both methods.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; On-column fluorimetric detection ; Gradient elution ; Dansyl amino acids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Fluorimetric detection in the presence of a stationary phase has been applied to gradient elution of dansyl amino acids in liquid chromatography. A 1.5 mm ID quartz tube packed with the same materials as the separation column was employed for the flow cell. Conventional-size columns were employed. The peak height of analytes increased with increasing retention owing to focusing and environmental effects of the stationary phase, leading to improvements in sensitivity, which was pronounced for analytes eluting late. The lower the gradient, the larger the improvement in sensitivity achieved. Detection limits were improved by a factor of up to 5.1 by fluorimetric detection using the packed flow cell, compared with those achieved using a common empty flow cell.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; LC-MS ; Cinchona alkaloids ; New column packing materials
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A major problem in the HPLC analysis of alkaloids is the poor peak shape and consequently low resolution, due to the interactions of the basic alkaloids with the residual acidic silanol groups of most reversed phase materials. The performance of new packing materials specially designed for the separation of basic compounds has been studied using mobile phases without the special additives commonly applied in the analysis of alkaloids. Strongly basic Cinchona alkaloids were used as test compounds. Retention characteristics and selectivities of each material were studied, after mobile phase optimisation for the column. The influence of the major factors (nature and content of the organic modifier, pH value, salt concentration) affecting resolution was studied. The mobile phases were chosen so that they could be used in thermospray LC-MS. The addition of salts to the mobile phase improves separation but in general the modification of the mobile phase gave little change in selectivity. The performance of silicabased C18 material proved superior to the polymer materials tested.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 320-324 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Microbore capillary columns ; Polymer based octadecylsilica bonded phase ; Fat soluble vitamins
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Separation behavior of fat soluble vitamins on various chemically bonded materials in non-aqueous reversedphases microcolumn liquid chromatography has been investigated. The best performance was found on a polymer-based octadecyl bonded phase. Optimization of separation for vitamins D2, D3, E and E acetate has been tried using this polymer-based column and it has been found that a binary mobile phase consisting of acetonitrile and methanol gave complete separation of fat soluble vitamins.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 331-336 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Microbore columns ; Injection techniques
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary This paper focuses attention on the potentially larger signal-to-noise ratios produced by microbore columns in comparison with conventional columns. The increased chromatographic signals by the application of microbore columns are due to the lower chromatographic dilution of elution profiles which are proportional to the square of the column inner radius. Generally less than 1μl sample should be injected into microbore systems to obtain the full benefit of the column performance. However, since more sample can be loaded on conventional columns compared to microbore columns the advantage of improved signal-to-noise ratio can only be realised in situations where very little sample is available. To inject more than 1μl sample, at the same time avoiding extra band-broadening effects, suitable injection techniques must be available. In this study three injection methods for microbore systems that meet this condition, are studied and compared.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Anion-exchange chromatography ; Xylenol orange ; Separation of nickel and zinc
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A liquid chromatographic procedure for separating nickel and zinc has been developed. Xylenol orange, which is one of the sensitive and commercially available color-forming agents, was used as a component of the mobile phase. The two ions could be separated on weak anion-exchange gels within 10 min. The procedure was suitable for the determination of nickel and zinc in relatively pure solutions with fairly high sensitivity. The described liquid chromatographic analysis would be also potentially applicable for any aqueous sample containing trace levels of metal cations at 1–10 ppm.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Oligosaccharides ; Interference by salts ; Complex biological samples ; Enzymatic assays
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the determination of oligosaccharides in samples of high salt content by RP-HPLC with water as eluent and refractive index detection. The samples, mussel processing wastes which are used as media for microfungus and yeast cultures and hence for enzymatic assays (amilolitic capacity) of these microorganisms that develop within the wastes, have been treated with ethanol to precipitate the macromolecular organic matter and desalted by a modified mixed bed resin before chromatographic analysis is carried out.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 23 (1987), S. 579-582 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Backflush technique ; Coal-derived procucts ; Separation of phenolic compounds
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid method was developed for the direct extraction of phenolic compounds from coal-derived products and subsequent isocratic HPLC analysis in a reversed-phase system by using the backflush technique.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 20 (1985), S. 587-590 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ion-pair chromatography ; Sulfonate pairing ion ; Adsorption isotherms
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The retention of positively and negatively charged and neutral solutes was studied in an aqueous phosphate buffer eluent, with constant inorganic-counterion concentration, on ODS-Hypersil stationary phase in the presence of various sulfonic acid ion-pairing reagents. The adsorption isotherms of the ion-pairing reagents d-camphor-10-sulfonic acid, sodium cyclohexylsulfamic acid and sodium alkylsulfonates (butyl-, hexyl- and octyl-) were determined by the breakthrough method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 20 (1985), S. 615-617 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Vitamin B2 in food ; Column switching ; Liquid-solid extraction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Vitamin B2 was enriched by liquid-solid extraction from large volumes of aqueous samples on a short precolumn. The enriched compounds were transferred onto an analytical reversed-phase column and separated by ion-pair chromatography. The equipment used provides the possibility of automation for routine analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Non-porous gel ; Alkaline-earth cations ; Arsenazo III
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A liquid chromatographic procedure for separating alkaline-earth-metal cations with a non-porous gel column has been developed. Arsenazo III, which is one of the sensitive and commercially available color-forming agents, was used as a component of the mobile phase. Magnesium and calcium could be separated on the nonporous gel column within 55 seconds. The procedure was suitable for the separation of alkaline-earth-metal cations in relatively pure solutions with high sensitivity. Because of its rapidity the described procedure is also potentially applicable for any aqueous sample.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Controlled-porosity glasses ; Chemically bonded phases ; Boron-glass surface enriched
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In the preparation of C18-bonded phases higher coverage densities were obtained using dimethylaminodimethyl-n-octadecylsilane than chlorodimethyl-n-octadecylsilane as the reagents. The HPLC results show the very high hydrophobicity of the materials obtained. The elution mechanism has been found to be independent of the coverage density on the boron-enriched glass surface in the range 2.3–4.0 μmol/m2.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Direct injection of biological samples ; New quinitidine metabolites ; Deproteinisation on precolumn ; Column switching
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary New quinidine metabolites, including 10,11-dihydrodiol quinidine N-oxide, 10,11-dihydrodiol quinidine and their glucuronides, were found in human urine. A quinidine monitoring HPLC method including these metabolites, is proposed by the direct injection of body fluid samples onto the precolumn for deproteinization followed by reverse phase separation in the analytical column with a column switching technique. The recovery of spiked quinidine and its metabolites in plasma was quantitative (98–102%) with good reproducibility (C.V.: 1.6–4.0%). Several clinical samples such as whole blood and urine were analyzed by the present method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Quantitative structure-retention relationships (QSRR) ; CNDO/2-MO Calculations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Retention data for 12 aromatic test solutes with functional groups of various polarities were studied on a wellcharacterized monomeric octadecyl stationary phase over a range of methanol/water compositions. CNDO calculations on the solute structures and regression analysis indicated that two terms, the total energy, ET, and the maximal difference of electron excess charge, Cd, correlated well with changes in retention as a function of methanol composition. This approach allowed for the non-empirical calculation of retention data for solutes with a range of polarities, overcoming previous deficiencies in the estimation of molecular polarity for non-homologous solutes based on total dipole moment.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Weak cation-exchanger ; Styrene-divinylbenzene copolymer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A weak cation-exchanger for high-performance liquid chromatography is obtained by oxidation of either poly(methylstyrene-divinylbenzene) or of poly(chloromethylstyrene-divinylbenzene). Reaction conditions were optimised to yield an exchange capacity of about 4meqg−1 dry resin. The material was evaluated chromatographically as a function of pH, organic modifier, temperature and flow rate. A combination of ionexchange and hydrophobic interaction between the solutes and the packing material was observed. This could be used to provide more options for realising chromatographic separations. Some chromatograms of heterocyclic bases, nucleosides, nucleotides and amino acids are shown.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...