ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 3 (1982), S. 227-235 
    ISSN: 0197-8462
    Keywords: microwaves ; pulsed-wave ; continuous-wave ; operant behavior ; DRL schedule ; rats ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The effects of pulsed-(PW) and continuous-wave (CW) 2.8-GHz microwaves were compared on the performance of rodents maintained by a temporally defined schedule of positive reinforcement. The schedule involved food-pellet reinforcement of behavior according to a differential-reinforcement-of-low-rate (DRL) contingency. The rats were independently exposed to PW and to CW fields at power densities ranging from 1 to 15 mW/cm2. Alterations of normal performance were more pronounced after a 30-minute exposure to the PW field than to the CW field. The rate of emission of appropriately timed responses declined after exposure to PW at 10 and 15 mW/cm2, whereas exposure at the same power levels to the CW field did not consistently affect the rate of responding. Change in performance associated with microwave exposure was not necessarily related to a general decline in responding: in some instances, increases in overall rates of responding were observed.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 7 (1986), S. 349-357 
    ISSN: 0197-8462
    Keywords: 60 Hz ; cyclotron resonance ; timing discrimination ; multiple schedule ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The present study demonstrates that operant behavior is affected by a combination of a 60-Hz magnetic field and a magnetostatic field 2.6 × 10-5T (about half the geomagnetic field). Rats exposed to this combination for 30 min consistently exhibited changes in the rate and pattern of responding during the differential reinforcement of low rate (DRL) component of a multiple fixed ratio (FR) DRL reinforcement schedule. By contrast, there were no measurable changes following exposure to the static field alone or to the oscillating field alone, even with a 10-fold increase in intensity (5 × 10-5 to 5 × 10-4 Trms). A cyclotron resonance mechanism has been suggested as a possible explanation for the observation that weak static magnetic fields modify the response of in vitro brain tissue to low-frequency magnetic fields. The choice of static field intensity Bo and frequency v in the present study follows from the cyclotron resonance condition v = (1/2π)(q/m)Bo, for singly charged lithium, an element in extensive use in the clinical treatment of affective disorders in humans. The present research is consistent with a cellular cyclotron resonance mechanism and tends to imply a functional dependence of behavior on the geomagnetic field.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 1 (1980), S. 89-99 
    ISSN: 0197-8462
    Keywords: repeated acquisition ; microwave radiation ; lever press ; rats ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The acute effects of microwave exposure on a repeated acquisition baseline were investigated in three rats. Each session the animals acquired a different four-member response sequence. Each of the first three correct responses advanced the sequence to the next member, and the fourth correct response produced food reinforcement. Incorrect responses produced a three-second timeout. Baseline and control sessions were characterized by a decrease in errors within each session. The animals were acutely exposed to a 2.8 GHz pulsed-microwave field prior to test sessions, with average power densities ranging from 0.25 to 10 mW/cm2. In comparison to control sessions, 1/2 hour of exposure to microwave radiation at power densities of 5 and 10 mW/cm2 increased errors and altered the pattern of within-session acquisition. Exposure to the 10 mW/cm2 power density decreased the rate of sequence completion in all animals. The results of exposures at 0.25, 0.5, and 1 mW/cm2 power densities were generally within the control range. The results are interpreted as indicating a disruption in the discriminative stimulus control of the repeated acquisition behavior.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 10 (1989), S. 111-113 
    ISSN: 0197-8462
    Keywords: cyclotron resonance ; timing discrimination ; A.C. threshold ; DRL schedule ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Experiments were conducted to further investigate the effect of 60-Hz cyclotron-resonance exposures on rats performing on a multiple FR-DRL schedule. The previously reported temporary loss of DRL baseline response, when measured as a function of A.C. magnetic intensity, was found to have a threshold. Utilizing the component of A.C. magnetic intensity parallel to the D.C. field, we report this threshold as (0.27 ± 0.10) × 10-4 Trms.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...