ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Sammlung
Verlag/Herausgeber
Erscheinungszeitraum
  • 1
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: A material subjected to traction stress increases in length; if we maintain the elongation constant, the stress varies over a period of time. This phenomenon has been referred to as relaxation. The purpose of this study was to define a mathematical law that relates the variation in stress to time when elongation remains constant in bovine pericardium. The mathematical function obtained after assaying 34 samples to the point of relaxation, subjected to initial stresses ranging from 0.17-10.07 MPa, responds to the following equation: y = -0.0252 + 0.953 α - (0.0165 + 0.015 α)lnt, where γ is the stress withstood at an instant in time, t, after initial stress α. A normogram, validated by assays of up to 6,340 min duration (4.40 days), is presented for graphic calculation, permitting the computation of the loss of stress due to relaxation of this biomaterial, with initial stresses ranging from 1-10 MPa. © 1994 John Wiley & Sons, Inc.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 0021-9304
    Schlagwort(e): biomaterial ; bioprostheses ; suture ; pericardium ; heart valves ; Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: The mechanical behavior of calf pericardium employed in the manufacture of cardiac bioprostheses was assessed according to the region from which it was selected. For this purpose, selected samples of the tissue were sewn with different types of commercially available sutures and subjected to tensile testing, the results of which were compared with the findings in selected, but not sutured, tissue used as a control. The results confirm a loss of resistance - that is, a reduction of the capacity of sutured samples of the biomaterial to withstand breakage stress compared with control samples. Taking into account the marked resistance to breakage of the suture thread, this phenomenon can only be explained as a consequence of the deleterious mechanical interaction between the suture and chemically treated pericardium. This interaction is illustrated by the shearing force which is responsible for the loss of resistance in the tested samples. These trials demonstrate that the results can be improved and the deleterious interaction diminished, although not eliminated, when the pericardium is selected from a given region. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 39, 568-574, 1998.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Since the development of cardiac bioprostheses, numerous chemical treatments have been assayed to prevent mineralization. The effectiveness of chemical treatments that eliminate lipids from the tissue was tested by combining two models. First, handmade bovine pericardial bioprostheses, subjected to chemical treatment with chloroform/methanol and glutaraldehyde or treated with glutaraldehyde alone for use as controls, were subjected to mechanical stress in a heart valve, accelerated wear tester (100 × 106 consecutive cycles). Then, the bioprostheses were unstitched and tissue samples were taken from the portion subjected to maximal stress (P1) and from that surrounding the sewing ring, which had not been subjected to mechanical stress (P2), for subcutaneous implantation. After 21 and 60 days of implantation, we observed calcification of the samples subjected to mechanical stress, even after delipidating treatment, with no significant differences with respect to the control group. However, the treated samples from the portion not subjected to mechanical stress presented a slighter accumulation of calcium after 60-day implantation (5.60 ± 3.09 mg Ca2+/g dry weight of tissue) versus the control group (47.17 ± 20.4 mg Ca2+/g dry weight of tissue), the difference of which was statistically significant (p 〈 0.01). At the time of these medium-term studies, marked calcification was observed in tissue subjected to delipidating treatment in the zones that underwent mechanical stress. © 1996 John Wiley & Sons, Inc.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...