Summary This work describes an HPLC method for the determination of formaldehyde concentration in air. Traps containing 20–40 mesh silica gel coated with 2,4-dinitrophenylhydrazine (DNPH) are used. After aspiration of air the traps are eluted with methanol. The hydrazone formed is then separated on a C18 column using a mobile phase of methanolwater (50–50 v/v). The effluent is monitored with a UV detector at 365 nm. To calibrate and to compare this method with that of Niosh 2502 (traps coated with 2 benzylamino ethanol on Chromosorb 102), a mixing chamber that generated atmospheres of known concentration of formaldehyde was used.