ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1
    Publication Date: 1963-02-01
    Print ISSN: 0028-0836
    Electronic ISSN: 1476-4687
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Published by Springer Nature
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 1970-03-01
    Print ISSN: 0028-0836
    Electronic ISSN: 1476-4687
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Published by Springer Nature
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Rheologica acta 8 (1969), S. 229-234 
    ISSN: 1435-1528
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Zusammenfassung Die Gelenksteifheit wird durch exakte physikalische Größen definiert. Es werden Methoden beschrieben, mit denen die Gelenksteifheit objektiv, qualitativ und quantitativ gemessen werden kann. Es wird eine Apparatur vorgestellt, die Messungen am Knie- und dem zweiten Metacarpophalangeal-Gelenk gestattet. Den Hauptanteil an der Gesamtsteifheit während einer Schwingung stellt die elastische Steifigkeit. Die plastische Steifigkeit erreichte Werte bis zu 40% der Gesamtsteifigkeit bei der Maximalamplitude. Bei kleinen Amplituden war dieCoulombsche Reibungssteifigkeit mit der elastischen Steifigkeit vergleichbar. Die viskose Steifigkeit ist gering.
    Notes: Summary Joint stiffness has been defined in precise physical terms. Methods are described whereby joint stiffness may be measured objectively, qualitatively and quantitatively. Apparatus is described to permit measurements to be made at the knee and the second metacarpophalangeal joints. The major contribution to overall stiffness during a particular oscillation was elastic stiffness. Plastic stiffness was significant (up to 40 per cent at maximum amplitude). At small amplitudesCoulomb frictional stiffness was comparable with plastic stiffness. Viscous stiffness was small.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 4 (1970), S. 128-128 
    ISSN: 1432-0827
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 197 (1963), S. 586-586 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Another aspect of elasto-hydrodynamie lubrication which is of interest to the designer is the stress field within the solids. In this respect the distribution of pressure within the lubricant is of paramount importance, and it is the purpose of this communication to report a preliminary ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 225 (1970), S. 956-957 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Synovial fluid consists of a long-chain high molecular weight polymer, hyaluronic acid, bound to protein, within a dialysate of blood plasma, the resulting fluid being clear, yellow and tacky to the touch7. It is well established that the fluid is shear thinning, the sort of viscosities measured ...
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Rheologica acta 8 (1969), S. 234-239 
    ISSN: 1435-1528
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Zusammenfassung Menschliche Gelenke sind viele Jahre lang untersucht worden. Diese Arbeit berichtet über Untersuchungen, die wesentliche Schmierungseigenschaften vom Standpunkt des Ingenieurs betrachten. Reibungsmessungen dienen dazu, das Auftreten verschiedener Reibungszustände nachzuweisen, wenn Proben von Gelenk-Knorpeln mit einer Synovial-Flüssigkeit geschmiert werden. Dabei erweist sich die Hyaluron-Säure als ein wirksames Grenzschmiermittel. Allerdings wird diese niedrige Reibung in den Gelenken nur erzeugt, wenn ein geschlossener Flüssigkeitsfilm zwischen den gleitenden Oberflächen vorhanden ist. Dieser Film, durch die Gelenke unter geringer Belastung erzeugt, wird durch einen kräftigen Preßfilm-Mechanismus bei starker Belastung, wie sie beim Laufen oder Stehen entsteht, unterstützt. Die Wirksamkeit des Preßfilms hängt von der Welligkeit der Knorpeloberfläche ab (gemessen mit Taststiftmethoden), weiterhin von eingeschlossenen Synovial-Flüssigkeitsmengen, die unter einer Belastungseinwirkung durch einen Filtermechanismus angereichert und gelartig werden.
    Notes: Summary Human joints have been studied for many years, and this paper reports work carried out to investigate their remarkable lubricating qualities from an engineerring aspect. Friction measurements were used to indicate the occurrence of different types of lubrication when using specimens of articular cartilage lubricated with synovial fluid. It was found that hyaluronic acid acted as an efficient boundary lubricant, but that low friction was produced in joints only when there was a full film of fluid between the sliding surfaces. This film, set up by joint movements under light load, would be maintained by a powerful squeeze film mechanism under heavy loads such as endured in walking or standing. The efficiency of this squeeze film depended on the undulations on the cartilage surface, (measured by stylus tracing methods), entrapping pools of synovial fluid which subsequently became enriched and gel-like by a filtration mechanism, under the action of the loads.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 7 (1969), S. 31-39 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire On a mené une étude sur l'usure des cavités cotyloîdes en P.T.F.E. (téflon) provoquées par des têtes de fémur en acier inoxydable de différentes tailles dans le cas d'un remplacement total de la hanche sur des sujets humains. Le défaut le plus important du Téflon était l'apparition d'une réaction tissulaire aux débris d'usure. Les articulations artificielles utilisant des cotyles en plastique doivent donc être étudiées de façon à produire un minimum de débris d'usure sur une période donnée. Plus le diamètre de la tête métallique est faible, moins il y a de débris d'usure, mais en-dessous d'une certaine dimension optimum, le taux de pénétration de la tête dans la cavité devient trop rapide. Les conclusions basées sur l'étude du comportement du téflon chez l'homme montrent que pour obtenir une durée de vie maximum de la cavité, la dimension optimum de la tête de fémur doit être égale à la moitié du diamètre extérieur de la cavité. On pense que ces observations peuvent être appliquées à d'autres matières plastiques que le téflon. Une observation clinique inattendue a révélé que l'usure d'un cotyle en téflon dépendait davantage de l'activité du sujet que de son poids.
    Abstract: Zusammenfassung Die Abnützung von Hüftgelenkspfannen aus PTFE bei verschiedenen Größen von Femurköpfen aus rostfreiem Stahl wurde für den vollständigen Hüftersatz beim Menschen untersucht. Das schwierigste Problem bei Mißerfolg mit PTFE war die Erzeugung einer Gewebsreaktion durch Abnützungsmaterial. Daher sollten künstliche Hüftgelenke mit Plastikgelenkpfannen so angelegt sein, daß in einer gegebenen Zeit ein minimales Volumen an Abnützungsmaterial entsteht. Je geringer der Durchmesser des Metallkopfes, um so kleiner ist das Volumen an Abnützungsmaterial. Unterhalb einer optimalen Größe wäre jedoch die Durchstoßung der Pfanne durch den kleinen Kopf zu schnell zu erwarten. Aus dem beobachteten Verhalten von PTFE im menschlichen Körper ist zu schließen, daß für größte Langlebigkeit der Pfanne die Optimalgröße des Femurkopfes die Hälfte des Außendurchmessers der Pfanne beträgt. Diese Beobachtungen können eventuell auch auf andere Plastikstoffe angewandt werden, welche geringere Abnützung zeigen als PTFE. Die klinische Praxis ergab die unerwartete Beobachtung, daß die Abnützung einer PTFE-Gelenkpfanne mehr von der Bewegungsaktivität des Patienten als von dem Körpergewicht abzuhängen schien.
    Notes: Abtract A study has been made of the wear of hip sockets of P.T.F.E. against various sizes of stainless steel femoral head in the course of total prosthetic replacement of the hip in the human subject. The most serious aspect of the failure of P.T.F.E. was the production of a tissue reaction by wear debris. Artificial hip joints using plastic sockets should, therefore, be designed to produce the minimum volume of wear debris over a given period. The smaller the diameter of the metal head the smaller the volume of wear debris, but below a certain optimal size the rate of penetration of the socket by the small head would be too rapid. Conclusions based on the observed behaviour of P.T.F.E. in the human body indicate that for the longest life of a socket the optimum size of femoral head will be half that of the external diameter of the socket. It is considered that these observations can be applied to other plastics more resistant to wearing than P.T.F.E. An unexpected observation from clinical practice was that the wear of a P.T.F.E. socket seemed to be more dependent on the activity of the patient than the weight of the patient.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...