ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 51-59 
    ISSN: 0886-9383
    Keywords: Deconvolution ; Jansson's method ; Peak restoration ; Iterative deconvolution ; Peak resolution ; Non-linear deconvolution ; Super-resolution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In previous papers Jansson's method was found to be successful at deconvolving severely overlapped gas chromatographic peaks. In the most recent paper the method was evaluated with respect to quantitative accuracy, peak area and retention time repeatability. The problems associated with deconvolving noisy data and some alternatives which can improve the ability of Jansson's method to deconvolve noisy data are discussed. These alternatives include presmoothing the data with a nine-point, third-order polynomial filter and data reblurring. This paper will test these methods on peaks with various degrees of resolution and signal-to-noise ratios.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 1 (1987), S. 79-90 
    ISSN: 0886-9383
    Keywords: Numerical deconvolution ; Peak resolution ; Peak separation ; Iterative deconvolution ; Jansson's method ; Super-resolution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Severely overlapped gas chromatographic peaks can be resolved using Jansson's method. Jansson's method is an iterative nonlinear deconvolution technique and consists of Van Cittert's algorithm with the relaxation factor a function of the kth estimate of the peak shape. The maximum peak amplitude of the instrument and peak non-negativity serve as constraints to improve the peak estimate. Super-resolution is achieved without significantly degrading the chromatogram signal-to-noise ratio. The method only requires a knowledge of the instrument impulse response function and maximum peak height.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 1 (1987), S. 175-183 
    ISSN: 0886-9383
    Keywords: Deconvolution ; Jansson's method ; Peak resolution ; Numerical deconvolution ; Super resolution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In a previous paper,1 Jansson's method was used to deconvolve overlapped gas chromatographic peaks. It was found that this method gave improved performance over conventional techniques such as perpendicular drop and shoulder quantitation.2,3 This paper will present the results of a comprehensive test of Jansson's method using several sample mixtures. These results will be compared to what can be obtained by using shoulder quantitation, perpendicular drop or an instrument with a longer column. A relatively large number of tests will be performed for each of the four mentioned methods of peak resolution, so there will be a reasonable statistical basis for the goodness of Jansson's method to resolve fused gas chromatographic peaks for a given set of instrument conditions. A brief review of Jansson's method and the modeling of a gas chromatographic process will also be presented.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 291-298 
    ISSN: 0886-9383
    Keywords: Deconvolution ; Jansson's method ; Peak restoration ; Iterative deconvolution ; Peak resolution ; Chromatographic deconvolution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The use of a cross-correlation prefiltering technique to enhance the ability of Jansson's iterative deconvolution procedure to deconvolve extremely noisy chromatographic data is investigated. Test cases include peaks whose resolutions are as low as 0.35 and whose signal-to-noise ratios are as low as 1:1. Evaluation criteria include RMS error, relative peak error and peak area repeatability. For comparison purposes, relative peak area errors and peak area variances are also evaluated for noisy but well resolved peaks that have only been prefiltered with the cross-correlation filter. Jansson's method in conjunction with cross-correlation prefiltering is shown not only to resolve overlapped peaks but in some cases to improve their signal-to-noise ratios. The study also establishes some limits to the capabilities of Jansson's method will regard to adverse data conditions.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 85-95 
    ISSN: 0886-9383
    Keywords: Deconvolution ; Gold's ratio ; Iterative deconvolution ; Chromatographic deconvolution ; Peak restoration ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper will consider the use of an iterative ratio technique called Gold's ratio method as an alternative to iterative constrained deconvolution methods for the restoration of overlapped and noisy chromatograpic peaks. The study will consist of first describing the technique and then evaluating its performance with respect to Jansson's deconvolution procedure. A Hewlett-Packard 5890A gas chromatograph will be used to generate most of the test data. The evaluation criteria will include convergence rates, peak area errors and variances, retention time variances and noise performance.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...