ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2020-10-28
    Description: Hydraulic fracturing (HF) at Preston New Road (PNR), Lancashire, United Kingdom, in August 2019, induced a number of felt earthquakes. The largest event (ML 2.9) occurred on 26 August 2019, approximately three days after HF operations at the site had stopped. Following this, in November 2019, the United Kingdom Government announced a moratorium on HF for shale gas in England. Here we provide an analysis of the microseismic observations made during this case of HF-induced fault activation. More than 55,000 microseismic events were detected during operations using a downhole array, the vast majority measuring less than Mw 0. Event locations revealed the growth of hydraulic fractures and their interaction with several preexisting structures. The spatiotemporal distribution of events suggests that a hydraulic pathway was created between the injection points and a nearby northwest–southeast-striking fault, on which the largest events occurred. The aftershocks of the ML 2.9 event clearly delineate the rupture plane, with their spatial distribution forming a halo of activity around the mainshock rupture area. Across clusters of events, the magnitude distributions are distinctly bimodal, with a lower Gutenberg–Richter b-value for events above Mw 0, suggesting a break in scaling between events associated with hydraulic fracture propagation, and events associated with activation of the fault. This poses a challenge for mitigation strategies that rely on extrapolating microseismicity observed during injection to forecast future behavior. The activated fault was well oriented for failure in the regional stress field, significantly more so than the fault activated during previous operations at PNR in 2018. The differing orientations within the stress field likely explain why this PNR-2 fault produced larger events compared with the 2018 sequence, despite receiving a smaller volume of injected fluid. This indicates that fault orientation and in situ stress conditions play a key role in controlling the severity of seismicity induced by HF.
    Print ISSN: 0895-0695
    Electronic ISSN: 1938-2057
    Topics: Geosciences
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...