Publication Date:
2019-07-18
Description:
The Atmospheric Radiation Measurement program studied water vapor abundance measurement at its southern Great Plains site in the fall of 1997. The program used a large number of instruments, including four solar radiometers. By measuring solar transmittance in the 0.94 micrometer water apor absorption band, they were able to measure columnar water vapor (CWV). In the second round of comparison we used the same radiative transfer model, and the same line-by-line code (which includes recently corrected H2O spectroscopy) to retrieve CWV from all four solar radiometers, thus decreasing the mean CWV by 8 - 13 %. The model was not responsible for the 8 % spread in CWV which remained.
Keywords:
Meteorology and Climatology
Type:
Applied Optics; 40; 12