ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2018-11-29
    Description: Background: In sickle cell anemia (SCA), hemoglobin S (HbS) polymerizes upon deoxygenation, resulting in sickling of red blood cells (RBCs). These deoxygenated RBCs have strongly reduced deformability, which contributes to the etiology of vaso-occlusive crises and chronic hemolytic anemia. There are no widely available clinical laboratory tests to directly monitor effects of disease modifying therapies (i.e. hydroxyurea) on RBC deformability. RBC deformability can be measured using a Laser Optical Rotational Red Cell Analyzer (Lorrca) ektacytometer (RR Mechatronics, the Netherlands), which measures RBC deformability over a range of osmolalities. Recently, a new module was added which consists of a method to measure RBC deformability, expressed as Elongation Index (EI), during controlled deoxygenation. This test, termed oxygenscan, has 3 key read out parameters: 1) EImax, which represents RBC deformability at normoxia; 2) EImin represents deformability upon deoxygenation; and 3) the point of sickling (PoS), the point at which a 〉5% decrease in EI is observed during deoxygenation, reflecting the patient-specific pO2 at which sickling begins (Figure 1). In this study, we correlated laboratory parameters associated with SCA disease severity with oxygenscan parameters to establish the clinical utility of this test. Methods: The discovery cohort consisted of 15 SCA patients (median age 22.0 years, 33.3% on hydroxyurea (HU)) enrolled at University Medical Center Utrecht (UMCU). The validation cohort consisted of 21 patients with SCA (median age 12.5 years, 76.2% on HU) from Texas Children's Hematology Center (TCHC). Oxygenscans were carried out in duplicates at both sites. Percentage dense RBC (%DRBC) were measured using an ADVIA hematology analyzer (Siemens) at TCHC only. In this study, we used Pearson's correlation to test for linear correlations between oxygenscan parameters EImax, EImin and PoS and clinically relevant laboratory parameters: total hemoglobin (Hb), absolute reticulocyte count (ARC), %HbS and %HbF, and %DRBC. Results: In both cohorts PoS significantly positively correlated with ARC (Figure 2A-B). In the UMCU cohort, total Hb levels also significantly positively correlated with EImax (Figure 2C), which was validated in the TCHC cohort (Figure 2D). HbF positively correlated with the EImin in both cohorts (Figure 2E-F). EImin also significantly negatively correlated with HbS (r=-0.828 p=
    Print ISSN: 0006-4971
    Electronic ISSN: 1528-0020
    Topics: Biology , Medicine
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...