    Description: Non-destructive testing (NDT) techniques are used in industry to evaluate the properties of a material, component or structure without causing any permanent damage. Among the techniques, pulsed eddy current (PEC) NDT is regarded as a new technique where a broadband pulse excitation is used, as opposed to single frequencies employed in conventional eddy current NDT. In this study, a 2D axisymmetric electromagnetic model of a PEC probe has been developed and it has been used to study the effects of the excitation coil diameter on the performance of PEC probes in sample thickness measurement. A PEC system has also been built to validate the model. Aluminium plates are used as the sample and they can be stacked up to replicate thickness from 1 mm to 10 mm. The results show that there is a very good correlation between the simulation and experimental results, with an average error of less than 10%. The results also suggest that the larger the diameter of the excitation coil, the deep...