    Publication Date: 2019-07-13
    Description: Single cell tests were benign for external short, inadvertent charge and overdischarge into reversal up to 4.5 A. At lower current loads cells die (may be due to excessive dendrite formation) benignly. String level external short circuits lead to an unbalanced overdischarge, with one cell going into reversal. The result is catastrophic violent venting. Unbalanced string overdischarges at different currents causes catastrophic violent venting also. Heat-to-vent is very dramatic displaying violent venting Simulated internal short is also catastrophic and displays violent venting. Battery is not UL-rated; hence does not have dual-fault tolerance or tolerance to inherent cell tolerance to failures Battery Design for NASA JSC's human-rated application for use on ISS was changed to include two bypass diodes per cell to provide for two-failure tolerance to overdischarge into reversal (and external short) hazards.
    Keywords: Electronics and Electrical Engineering
    Type: JSC-CN-29795 , 2013 NASA Battery Workshop; Nov 05, 2013 - Nov 07, 2013; Huntsville, AL; United States