    Publication Date: 2013-08-31
    Description: Around resonance, the force transmitted by an exciter into a structure will be smaller or greater than a reference force generated by its coils due to electromechanical interaction. A simple analysis is presented which reveals how this phenomenon of force drop-off is controlled by three factors. The first factor, called Armature Mass Factor, describes a purely mechanical interaction between the structure and the exciter. The electromechanical energy conversion and its interaction with the structure yields two additional factors, called Electrical Resistance and Electrical Inductance Factors. They describe the effects of coil resistance, inductance and magnetic field strength relative to structural damping and stiffness. Present analysis indicates that, under proper circumstances, more than 90 percent of the force drop-off can be eliminated if armature-to-structure mass ratio is smaller or equal to half of modal loss factor.
    Keywords: STRUCTURAL MECHANICS
    Type: NASA-Marshall Space Flight Center, The 58th Shock and Vibration Symposium, Volume 1; p 245-255