Publication Date:
2016-06-07
Description:
The accuracy of velocity measurements made with a laser velocimeter is strongly dependent upon the response of the seeding particles to the dynamics of the flow field. The smaller the particle the better the response to flow fluctuations and gradients and therefore the more accurate velocity measurement. In direct conflict is the requirement of light scattering efficiency to obtain signals with the laser velocimeter which, in general, is better as the particle size is increased. In low speed flow fields these two requirements on particle size overlap and accurate measurements may be obtained. However in high speed flows, where the velocity gradients may be severe, very small particles are required to maintain sufficient dynamic response characteristics to follow the flow. Therefore if velocity measurements are to be made in these flows, the laser velocimeter must be designed with sufficient sensitivity to obtain signals from these small particles. An insitu determination of the size distribution of kaolin particles (Al2O3, .2 + or - SiO2 . 2H2O) in the 16-foot Transonic Tunnel and the sensitivity characteristics of the laser velocimeter system is described.
Keywords:
INSTRUMENTATION AND PHOTOGRAPHY
Type:
Wind Tunnel Seeding Systems for Laser Velocimeters; p 29-51
Format: