Publication Date:
2011-08-17
Description:
A blunt probe experiment for measuring electrical conductivity was flown with the STRATCOM 8 instrument package. Data were obtained by the instrument throughout the entire measurement period. A preliminary analysis of the data indicates an enhancement in conductivity associated with the krypton discharge ionization lamp, particularly in negative conductivity. The conductivity values and their altitude dependence are consistent with previous balloon and rocket results.
Keywords:
GEOPHYSICS
Type:
NASA. Goddard Space Flight Center STRATCOM 8 Data Workshop and Suppl.; p 96-102
Format:
text