Publication Date:
2011-08-16
Description:
Comparison of the new generation of air quality monitoring instruments with some more traditional methods. The first generation of air quality measurement instruments, based on the use of oxidant coulometric cells, nitrogen oxide colorimetry, carbon monoxide infrared analyzers, and other types of detectors, is compared with new techniques now coming into wide use in the air monitoring field and involving the use of chemiluminescent reactions, optical absorption detectors, a refinement of the carbon monoxide infrared analyzer, electrochemical cells based on solid electrolytes, and laser detectors.
Keywords:
INSTRUMENTATION AND PHOTOGRAPHY
Type:
IEEE Transactions on Aerospace and Electronic Systems; AES-9; Jan. 197
Format:
text