We have designed and constructed a vacuum heat treatment facility, with hot zone dimensions of 12×19×19 cm, at a cost substantially below that of a commercial unit. The design incorporates efficient water cooling and a resistive heating element. A vacuum pressure of 1.5×10−8 Torr at room temperature has been obtained after baking. The temperature limit is approximately 1900 °C. This limit results from our choice of niobium as the hot zone material.