Summary Oxygen supply is a critical point in technical processes when aerobic cells are used in immobilized preparations. This report concerns the use of hemoglobin or emulsions of perfluorochemicals (completely fluorinated organic compounds) to carry oxygen to immobilized cells. Both methods work well and do not seem to harm the cells. The perfluorochemical method of improving oxygen supply showed a higher operational stability than the hemoglobin method.