Electronic Resource
Springer
International journal of thermophysics
14 (1993), S. 1221-1227
ISSN:
1572-9567
Keywords:
Burnett apparatus
;
HFC-32
;
refrigerants
;
vapor pressure
Source:
Springer Online Journal Archives 1860-2000
Topics:
Physics
Notes:
Abstract A slightly modified Burnett apparatus has been used to measure 32 vapor-pressure data for HFC-32 in the temperature range from 273.39 to 347.29 K. The uncertainties of temperature and pressure are estimated to be within ±10 mK and ±500 Pa, respectively. The purity of the sample used in this work is 99.95%. On the basis of our data and of data from the literature, a vapor-pressure equation for HFC-32 is also proposed.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF02431286
|
Location |
Call Number |
Expected |