ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Angewandte Makromolekulare Chemie 192 (1991), S. 57-67 
    ISSN: 0003-3146
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Die Morphologien von spritzgegossenem und formgepreßtem Poly(1-buten) (PB-1) wurden im Polarisationsmikroskop und im Transmissionselektronenmikroskop untersucht. Eine dünne Oberflächenhaut und bis in den Kern der Probekörper reichende abgeplattet-sphärolithische Strukturen werden bei spritzgegossenem PB-1 beobachtet, während in formgepreßtem PB-1 typische Sphärolithe vorliegen. Das Bruchbild des spritzgegossenen PB-1 zeigt unter der Oberflächenhaut viele aufgereihte streifenartige Hohlräume, die senkrecht zur Spritzrichtung zur Mitte des Probekörpers wachsen. Aus diesen Beobachtungen kann geschlossen werden, daß eine beim Spritzgießen durch den Schmelzefluß induzierte Scherspannung nicht nur die Entstehung der Oberflächenhaut verursacht, sondern auch bis in die Mitte des Probekörpers hinein die Bildung abgeplatteter Sphärolithe bewirkt. Diese abgeplattet-sphärolithischen Strukturen sind für die beim Dehnen des spritzgegossenen PB-1 entstehenden, streifenartigen Hohlräume verantwortlich, während die Oberflächenhaut und die abgeplatteten Sphärolithe im Kern die Sprödigkeit und die im Vergleich zu formgepreßtem PB-1 geringere Bruchdehnung bewirken. Diese kann durch Tempern oberhalb des Schmelzpunktes erhöht werden.
    Notes: The injection-molded poly(1-butene) (PB-1) is found to be more brittle than the compression-molded PB-1. The morphologies of these specimens are examined by use of polarized optical microscopy and scanning electron microscopy (SEM). A skin layer and an oblate spherulitic structure extended to the core region are observed in the injection-molded PB-1, while typical spherulites exist in the compression-molded PB-1. Below the skin layer of the injection-molded PB-1, the fracture surface is found to consist of many aligned strip-like voids with ribbon edges propagating to the center of the specimen and perpendicular to the flow direction of injection-molding. Based on these observations, it can be inferred that shear stress induced by the melt flow during the injection-molding does not only cause the formation of skin layer, but also penetrates deeply into the central region of the injection-molded specimen causing the formation of oblate spherulites. The oblate spherulitic structure is responsible for the aligned voids during elongation of PB-1, while the existence of the skin layer and the oblate spherulites in core region is responsible for the brittleness of the injection-molded PB-1. The elongation of the injection-molded PB-1 is found to be lower than that of the compression-molded. This can be attributed not only to the presence of the skin layer but also to the oblate spherulites in the core region. The elongation can be improved by annealing at a temperature above the melting point of PB-1.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...