ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Cellular Physiology 101 (1979), S. 407-417 
    ISSN: 0021-9541
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: When replicating DNA is labeled sequentially with radioactive and density tracers and analyzed by equilibrium centrifugation, the fraction banding at heavier than normal density is inversely proportional to the rate of replication fork movement if there is a sharp transition from one tracer to the other on the newly synthesized chains (Painter and Schaefer, '69). Primate CV-1 DNA labeled for 5 to 30 minutes with 3H-dThd and then for three hours with BrdUrd in the presence of FdUrd bands in a bimodal distribution in alkaline CsCl, rather than in a continuous distribution with a skew toward heavier density seen when FdUrd is omitted and centrifugation is in neutral CsCl. The heavy density peak represents interspersion of both tracers in the DNA and is caused by slow transition from dThd to BrdUrd incorporation when the tracers are switched in the labeling medium. This may result from preferential uptake and incorporation of dThd over BrdUrd. Because of the interspersion, calculation of the rate of replication fork movement is inaccurate. Reversal of the labeling sequence with administration of the long density pulse before the radioactive pulse reduces the problem of interspersion. Using this sequence of labeling, estimates of the rate of fork movement of 0.36-0.38 μm/min are obtained when the 3H pulse time is long enough to allow accurate measurement of the fraction of heavy DNA. Analysis by fiber autoradiography yields a rate of 0.56 μm/min in the same cell line. If appropriate precautions are taken to minimize mixing of the two tracers in the precursor pool and to ensure that the fraction of heavy DNA is measured accurately, the hydrodynamic technique provides an objective method of measuring rate of fork movement that gives values only slightly lower than those obtained by autoradiography.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...