ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The release of corrosion products by implants has become a matter of concern. Using a microsphere model, the release of chromium, cobalt, and nickel, secondary to implantation of various surface area exposures of F-75, a cast cobalt-chromium alloy, was studied over a 30 day period in the rat. Dose related elevations were observed in the serum concentration of chromium and cobalt but not of nickel, with the maxima being achieved at 3 days after metal implantation followed by declines in concentration. The chromium elevation, approximately twelvefold for a surface area to body weight (SA/BW) ratio of 300 x is similar to that previously reported in patients receiving total hip replacement arthoplasties. However, the cobalt elevation, twentyfold for a SA/BW ratio of 300 x, has not been previously observed. These serum concentration changes are as yet unexplained, but are probably not due to fibrous capsule maturation or alloy repassivation.
    Additional Material: 4 Ill.