ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 42 (1993), S. 1175-1180 
    ISSN: 0006-3592
    Keywords: self-cycling fermentation ; secondary metabolite ; biosurfactant ; fermentation ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Self-cycling fermentations (SCFs) were conducted in a stirred tank apparatus using Bacillus subtilis and Acinetobacter calcoaceticus. The systems were very stable and the experiments lasted through many cycles. The variation of parameters such as biomass and doubling time from cycle to cycle was small. The stirred tank reactor (STR) allowed a much better control of the working volume in the fermentor from cycle to cycle, compared to the cyclone column, and it was not necessary to make periodic corrections.The production of surfactin from B. subtilis was achieved without extending the cycle time. The harvested broth at the end of each cycle was allowed to remain in a secondary vessel, at ambient temperature, before being collected. It is exhaustion of the limiting nutrient which causes an increase in dissolved oxygen (DO). At this point, the computer, which constantly monitors the DO, triggered the harvesting sequence to end the cycle. Thus, the mature culture in the secondary vessel experienced appropriate conditions for the production of the secondary metabolite. Meanwhile, the next batch of cells was being grown in the primary reactor.The response of a gas analyzer on the effluent paralleled that of the DO measurements in the fermentor. These data for oxygen and carbon dioxide exhibited less noise than the DO readings. Either would be a more reliable parameter for feedback control of the SCF because the problem of fouling of the DO probe after extended runs of many cycles would be eliminated. © 1993 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...