ISSN:
0001-1541
Keywords:
Chemistry
;
Chemical Engineering
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
,
Process Engineering, Biotechnology, Nutrition Technology
Notes:
A magnetic thermometric method is used to determine cross-sectional average axial catalyst temperature profiles for superparamagnetic neckel catalyst beds during ethane hydrogenolysis, an exothermic reaction. Each solid temperature profile is determined from an axial profile of cross-sectional average magnetization and is represented by a polynomial. In turn, each magnetization profile is determined from voltage data obtained as the bed is moved through an AC permeameter. A Fredholm equation of the first kind, “regularized” using a minimum variance constraint, is inverted to determine the magnetization profile.The determination of the axial temperature profile for a reactor operating at 11.0% conversion is detailed. It provides a good test of the method used. Some limitations of the method are highlighted by attempts to analyze data from a reactor operating at complete conversion. The potential for model parameter estimation is discussed.
Additional Material:
5 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/aic.690350903