ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Weitere Quellen  (29)
  • ddc:548  (28)
  • Deutschland
  • 2020-2024  (29)
Sammlung
Datenquelle
Schlagwörter
Sprache
Jahr
  • 1
    Publikationsdatum: 2024-04-25
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉〈italic〉INSIGHT〈/italic〉 is a Python‐based software tool for processing and reducing 2D grazing‐incidence wide‐ and small‐angle X‐ray scattering (GIWAXS/GISAXS) data. It offers the geometric transformation of the 2D GIWAXS/GISAXS detector image to reciprocal space, including vectorized and parallelized pixel‐wise intensity correction calculations. An explicit focus on efficient data management and batch processing enables full control of large time‐resolved synchrotron and laboratory data sets for a detailed analysis of kinetic GIWAXS/GISAXS studies of thin films. It processes data acquired with arbitrarily rotated detectors and performs vertical, horizontal, azimuthal and radial cuts in reciprocal space. It further allows crystallographic indexing and GIWAXS pattern simulation, and provides various plotting and export functionalities. Customized scripting offers a one‐step solution to reduce, process, analyze and export findings of large 〈italic〉in situ〈/italic〉 and 〈italic〉operando〈/italic〉 data sets.〈/p〉
    Schlagwort(e): ddc:548 ; grazing‐incidence X‐ray scattering ; time‐resolved studies ; in situ studies ; operando studies ; computer programs
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Publikationsdatum: 2023-07-04
    Beschreibung: The recent diversification of macromolecular crystallographic experiments including the use of pink beams, convergent electron diffraction and serial snapshot crystallography has shown the limitations of using the Laue equations for diffraction prediction. This article gives a computationally efficient way of calculating approximate crystal diffraction patterns given varying distributions of the incoming beam, crystal shapes and other potentially hidden parameters. This approach models each pixel of a diffraction pattern and improves data processing of integrated peak intensities by enabling the correction of partially recorded reflections. The fundamental idea is to express the distributions as weighted sums of Gaussian functions. The approach is demonstrated on serial femtosecond crystallography data sets, showing a significant decrease in the required number of patterns to refine a structure to a given error.
    Beschreibung: Reflection position, size and shape prediction and partiality estimation of crystal diffraction by integrating using a Gaussian basis are described.
    Schlagwort(e): ddc:548 ; partiality estimation ; diffraction prediction ; merging ; serial snapshot crystallography
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Publikationsdatum: 2023-06-12
    Beschreibung: Soils and landscapes are bridges of space and time, as they simultaneously and authentically show essential aspects that were previously separated by time and space (such as cultural and activity-related aspects from past and present) to the trained observer - albeit only in excerpts. Therefore, this article presents a series of impact indicators for soil changes, starting with extreme (anthropogenic) interventions and ending with equally extreme ("natural") events. An essential difference to specifically planning-relevant or human ecological concepts, which, for example, specify land use/load categories, is that the following impact indicators perceive soils as a phenomenon in themselves and do not define them through attributed functions. Particular attention is focused on their changeability and vital development potential, as well as on their property as a sphere of penetration of living and material things, with emphasis on the noetic effect. The intervention or event spaces on the earth's surface can be differentiated quantitatively through the type, strength, and duration of the phenomena. The intensity of all processes can be described by amplitude (the strength of the interventions/events) and frequency (the repetition rate of the interventions/events) and can be specifically identified and quantified by, for example, material inputs or outputs per unit of time. For the first time, there would be a system for measuring the ecological quality of anthropogenic land use, which could serve as an "alert system for the external technological culture," and could help us become aware of our "inner" culture.
    Beschreibung: research
    Schlagwort(e): ddc:550 ; Boden ; Landschaft ; Bodendegeneration ; Deutschland ; Anthropogene Bodenveränderung
    Sprache: Deutsch
    Materialart: doc-type:article
    Format: 9
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Publikationsdatum: 2023-10-24
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉Complex functional materials play a crucial role in a broad range of energy‐related applications and in general for materials science. Revealing the structural mechanisms is challenging due to highly correlated coexisting phases and microstructures, especially for 〈italic〉in situ〈/italic〉 or 〈italic〉operando〈/italic〉 investigations. Since the grain sizes influence the properties, these microstructural features further complicate investigations at synchrotrons due to the limitations of illuminated sample volumes. In this study, it is demonstrated that such complex functional materials with highly correlated coexisting phases can be investigated under 〈italic〉in situ〈/italic〉 conditions with neutron diffraction. For large grain sizes, these experiments are valuable methods to reveal the structural mechanisms. For an example of 〈italic〉in situ〈/italic〉 experiments on barium titanate with an applied electric field, details of the electric‐field‐induced phase transformation depending on grain size and frequency are revealed. The results uncover the strain mechanisms in barium titanate and elucidate the complex interplay of stresses in relation to grain sizes as well as domain‐wall densities and mobilities.〈/p〉
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉This work reports 〈italic〉in situ〈/italic〉 neutron diffraction experiments on a broad range of grain sizes of barium titanate. The study reveals the grain‐size‐dependent strain mechanisms and shows the competitiveness of neutron diffraction with high‐resolution synchrotron diffraction.〈boxed-text position="anchor" content-type="graphic" xml:lang="en"〉〈graphic position="anchor" id="jats-graphic-1" xlink:href="urn:x-wiley:16005767:jcr2vb5054:jcr2vb5054-fig-0001"〉 〈alt-text〉image〈/alt-text〉 〈/graphic〉〈/boxed-text〉〈/p〉
    Schlagwort(e): ddc:550.724 ; ddc:548 ; neutron diffraction ; in situ ; applied electric fields ; barium titanate ; strain mechanisms ; grain sizes ; complex functional materials ; microstructures ; coexisting phases
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Publikationsdatum: 2023-09-12
    Beschreibung: Two data evaluation concepts for X‐ray stress analysis based on energy‐dispersive diffraction on polycrystalline materials with cubic crystal structure, almost random crystallographic texture and strong single‐crystal elastic anisotropy are subjected to comparative assessment. The aim is the study of the residual stress state in hard‐to‐reach measurement points, for which the sin2ψ method is not applicable due to beam shadowing at larger sample tilting. This makes the approaches attractive for stress analysis in engineering parts with complex shapes, for example. Both approaches are based on the assumption of a biaxial stress state within the irradiated sample volume. They exploit in different ways the elastic anisotropy of individual crystallites acting at the microscopic scale and the anisotropy imposed on the material by the near‐surface stress state at the macroscopic scale. They therefore complement each other, in terms of both their preconditions and their results. The first approach is based on the evaluation of strain differences, which makes it less sensitive to variations in the strain‐free lattice parameter a0. Since it assumes a homogeneous stress state within the irradiated sample volume, it provides an average value of the in‐plane stresses. The second approach exploits the sensitivity of the lattice strain to changes in a0. Consequently, it assumes a homogeneous chemical composition but provides a stress profile within the information depth. Experimental examples from different fields in materials science, namely shot peening of austenitic steel and in situ stress analysis during welding, are presented to demonstrate the suitability of the proposed methods.
    Beschreibung: The single‐crystal elastic anisotropy and the anisotropy of the near‐surface (residual) stress state of polycrystalline materials with random texture are exploited in energy‐dispersive X‐ray stress analysis to study samples under constrained measurement conditions.
    Schlagwort(e): ddc:548 ; X‐ray stress analysis ; energy‐dispersive diffraction ; polycrystalline materials ; single‐crystal elastic anisotropy
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Publikationsdatum: 2023-07-20
    Beschreibung: A pseudosymmetric description of the crystal lattice derived from a single wide‐angle Kikuchi pattern can have several causes. The small size (〈15%) of the sector covered by an electron backscatter diffraction pattern, the limited precision of the projection centre position and the Kikuchi band definition are crucial. Inherent pseudosymmetries of the crystal lattice and/or structure also pose a challenge in the analysis of Kikuchi patterns. To eliminate experimental errors as much as possible, simulated Kikuchi patterns of 350 phases have been analysed using the software CALM [Nolze et al. (2021). J. Appl. Cryst.54, 1012–1022] in order to estimate the frequency of and reasons for pseudosymmetric crystal lattice descriptions. Misinterpretations occur in particular when the atomic scattering factors of non‐equivalent positions are too similar and reciprocal‐lattice points are systematically missing. As an example, a pseudosymmetry prediction depending on the elements involved is discussed for binary AB compounds with B1 and B2 structure types. However, since this is impossible for more complicated phases, this approach cannot be directly applied to compounds of arbitrary composition and structure.
    Beschreibung: Distinguishing between actual and apparent pseudosymmetry in electron backscatter diffraction patterns is nearly impossible, even for simulated patterns. However, the resulting lattice is always a superlattice as long as the signal is not a superposition of multiple patterns.
    Schlagwort(e): ddc:548 ; Bravais lattices ; pseudosymmetry ; lattice point density ; ordered/disordered structures ; lattice distortion ; electron backscatter diffraction ; backscattered Kikuchi diffraction patterns ; lattice parameters ; Funk transform
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Publikationsdatum: 2023-07-21
    Beschreibung: A band width determination using the first derivative of the band profile systematically underestimates the true Bragg angle. Corrections are proposed to compensate for the resulting offset Δa/a of the mean lattice parameters derived from as many Kikuchi band widths as possible. For dynamically simulated Kikuchi patterns, Δa/a can reach up to 8% for phases with a high mean atomic number Z, whereas for much more common low‐Z materials the offset decreases linearly. A predicted offset Δa/a = f(Z) is therefore proposed, which also includes the unit‐cell volume and thus takes into account the packing density of the scatterers in the material. Since Z is not always available for unknown phases, its substitution by Zmax, i.e. the atomic number of the heaviest element in the compound, is still acceptable for an approximate correction. For simulated Kikuchi patterns the offset‐corrected lattice parameter deviation is Δa/a 〈 1.5%. The lattice parameter ratios, and the angles α, β and γ between the basis vectors, are not affected at all.
    Beschreibung: Automatically determined band widths in simulated backscatter Kikuchi patterns exhibit differences from the double Bragg angles that correlate with the scatterer density. Corrections are proposed to compensate for this.
    Schlagwort(e): ddc:548 ; mean atomic number ; Kikuchi patterns ; lattice parameters ; automated Bragg angle determination ; lattice parameter determination ; dynamical theory of electron diffraction ; electron backscatter diffraction ; Funk transform
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Publikationsdatum: 2023-07-21
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉The high‐intensity time‐of‐flight (TOF) neutron diffractometer POWTEX for powder and texture analysis is currently being built prior to operation in the eastern guide hall of the research reactor FRM II at Garching close to Munich, Germany. Because of the world‐wide 〈sup〉3〈/sup〉He crisis in 2009, the authors promptly initiated the development of 〈sup〉3〈/sup〉He‐free detector alternatives that are tailor‐made for the requirements of large‐area diffractometers. Herein is reported the 2017 enterprise to operate one mounting unit of the final POWTEX detector on the neutron powder diffractometer POWGEN at the Spallation Neutron Source located at Oak Ridge National Laboratory, USA. As a result, presented here are the first angular‐ and wavelength‐dependent data from the POWTEX detector, unfortunately damaged by a 50〈italic〉g〈/italic〉 shock but still operating, as well as the efforts made both to characterize the transport damage and to successfully recalibrate the voxel positions in order to yield nonetheless reliable measurements. Also described is the current data reduction process using the 〈italic〉PowderReduceP2D〈/italic〉 algorithm implemented in 〈italic〉Mantid〈/italic〉 [Arnold 〈italic〉et al.〈/italic〉 (2014). 〈italic〉Nucl. Instrum. Methods Phys. Res. A〈/italic〉, 〈bold〉764〈/bold〉, 156–166]. The final part of the data treatment chain, namely a novel multi‐dimensional refinement using a modified version of the 〈italic〉GSAS‐II〈/italic〉 software suite [〈ext-link ext-link-type="uri" xlink:href="http://scripts.iucr.org/cgi-bin/paper?aj5212"〉Toby & Von Dreele (2013). 〈italic〉J. Appl. Cryst.〈/italic〉〈bold〉46〈/bold〉, 544–549〈/ext-link〉], is compared with a standard data treatment of the same event data conventionally reduced as TOF diffraction patterns and refined with the unmodified version of 〈italic〉GSAS‐II〈/italic〉. This involves both determining the instrumental resolution parameters using POWGEN's powdered diamond standard sample and the refinement of a friendly‐user sample, BaZn(NCN)〈sub〉2〈/sub〉. Although each structural parameter on its own looks similar upon comparing the conventional (1D) and multi‐dimensional (2D) treatments, also in terms of precision, a closer view shows small but possibly significant differences. For example, the somewhat suspicious proximity of the 〈italic〉a〈/italic〉 and 〈italic〉b〈/italic〉 lattice parameters of BaZn(NCN)〈sub〉2〈/sub〉 crystallizing in 〈italic〉Pbca〈/italic〉 as resulting from the 1D refinement (0.008 Å) is five times less pronounced in the 2D refinement (0.038 Å). Similar features are found when comparing bond lengths and bond angles, 〈italic〉e.g.〈/italic〉 the two N—C—N units are less differently bent in the 1D results (173 and 175°) than in the 2D results (167 and 173°). The results are of importance not only for POWTEX but also for other neutron TOF diffractometers with large‐area detectors, like POWGEN at the SNS or the future DREAM beamline at the European Spallation Source.〈/p〉
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉The first real‐world neutron diffraction data have been collected with one of the POWTEX detectors (FRM II, Garching, Germany) mounted for testing at the Spallation Neutron Source (Oak Ridge National Laboratory, USA). They allow for angular‐ and wavelength‐dispersive Rietveld refinement using a modified version of 〈italic〉GSAS‐II〈/italic〉.〈boxed-text position="anchor" content-type="graphic" xml:lang="en"〉〈graphic position="anchor" id="jats-graphic-1" xlink:href="urn:x-wiley:16005767:jcr2tu5033:jcr2tu5033-fig-0001"〉 〈/graphic〉〈/boxed-text〉〈/p〉
    Schlagwort(e): ddc:548 ; neutron detectors ; POWGEN beamline ; POWTEX detector ; DREAM beamline ; time‐of‐flight diffraction ; angular‐dispersive refinement ; wavelength‐dispersive refinement ; powder diffraction ; Rietveld refinement ; multi‐dimensional refinement
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    facet.materialart.
    Unbekannt
    International Union of Crystallography | 5 Abbey Square, Chester, Cheshire CH1 2HU, England
    Publikationsdatum: 2023-07-21
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉The paper by Gopalan [〈ext-link ext-link-type="uri" xlink:href="http://scripts.iucr.org/cgi-bin/paper?ib5086"〉(2020). 〈italic〉Acta Cryst.〈/italic〉 A〈bold〉76〈/bold〉, 318–327〈/ext-link〉] presented an enumeration of the 41 physical quantity types in non‐relativistic physics, in arbitrary dimensions, based on the formalism of Clifford algebra. Gopalan considered three antisymmetries: spatial inversion, 〈overline〉1〈/overline〉, time reversal, 1′, and wedge reversion, 1〈sup〉†〈/sup〉. A consideration of the set of all seven antisymmetries (〈overline〉1〈/overline〉, 1′, 1〈sup〉†〈/sup〉, 1′〈sup〉†〈/sup〉, 〈overline〉1〈/overline〉〈sup〉†〈/sup〉, 〈overline〉1〈/overline〉′, 〈overline〉1〈/overline〉′〈sup〉†〈/sup〉) leads to an extension of the results obtained by Gopalan. It is shown that there are 51 types of physical quantities with distinct symmetry properties in total.〈/p〉
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉It is shown that there are 51 types of physical quantities in arbitrary dimensions with distinct transformations by wedge reversion symmetry. In the paper by 〈ext-link ext-link-type="uri" xlink:href="http://scripts.iucr.org/cgi-bin/paper?ib5086"〉Gopalan [(2020). 〈italic〉Acta Cryst.〈/italic〉 A〈bold〉76〈/bold〉, 318–327]〈/ext-link〉 only 41 types were enumerated.〈boxed-text position="anchor" content-type="graphic" xml:lang="en"〉〈graphic position="anchor" id="jats-graphic-1" xlink:href="urn:x-wiley:20532733:aya2ib5117:aya2ib5117-fig-0001"〉 〈alt-text〉image〈/alt-text〉 〈/graphic〉〈/boxed-text〉〈/p〉
    Schlagwort(e): ddc:548 ; multivectors ; wedge reversion ; antisymmetry ; Clifford algebra
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Publikationsdatum: 2023-07-19
    Beschreibung: The derivation of a crystal structure and its phase‐specific parameters from a single wide‐angle backscattered Kikuchi diffraction pattern requires reliable extraction of the Bragg angles. By means of the first derivative of the lattice profile, an attempt is made to determine fully automatically and reproducibly the band widths in simulated Kikuchi patterns. Even under such ideal conditions (projection centre, wavelength and lattice plane traces are perfectly known), this leads to a lattice parameter distribution whose mean shows a linear offset that correlates with the mean atomic number Z of the pattern‐forming phase. The consideration of as many Kikuchi bands as possible reduces the errors that typically occur if only a single band is analysed. On the other hand, the width of the resulting distribution is such that higher image resolution of diffraction patterns, employing longer wavelengths to produce wider bands or the use of higher interference orders is less advantageous than commonly assumed.
    Beschreibung: The lattice parameters of more than 350 phases have been determined from simulated backscatter Kikuchi patterns. The deviations correlating with the mean atomic number correspond to those observed previously for experimental electron backscatter diffraction patterns.
    Schlagwort(e): ddc:548 ; Bragg angles ; Kikuchi bands ; Kikuchi patterns ; first derivative ; lattice parameters ; lattice parameter determination ; Bravais lattice type ; electron backscatter diffraction ; Radon transform
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 11
    Publikationsdatum: 2023-07-19
    Beschreibung: Serial crystallography experiments produce massive amounts of experimental data. Yet in spite of these large‐scale data sets, only a small percentage of the data are useful for downstream analysis. Thus, it is essential to differentiate reliably between acceptable data (hits) and unacceptable data (misses). To this end, a novel pipeline is proposed to categorize the data, which extracts features from the images, summarizes these features with the `bag of visual words' method and then classifies the images using machine learning. In addition, a novel study of various feature extractors and machine learning classifiers is presented, with the aim of finding the best feature extractor and machine learning classifier for serial crystallography data. The study reveals that the oriented FAST and rotated BRIEF (ORB) feature extractor with a multilayer perceptron classifier gives the best results. Finally, the ORB feature extractor with multilayer perceptron is evaluated on various data sets including both synthetic and experimental data, demonstrating superior performance compared with other feature extractors and classifiers.
    Beschreibung: A machine learning method for distinguishing good and bad images in serial crystallography is presented. To reduce the computational cost, this uses the oriented FAST and rotated BRIEF feature extraction method from computer vision to detect image features, followed by a multilayer perceptron (neural network) to classify the images.
    Schlagwort(e): ddc:548 ; serial crystallography ; data reduction ; machine learning ; feature extraction
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 12
    facet.materialart.
    Unbekannt
    International Union of Crystallography | 5 Abbey Square, Chester, Cheshire CH1 2HU, England
    Publikationsdatum: 2023-07-19
    Beschreibung: Since high‐pressure devices have been used at synchrotron facilities, accurate determination of pressure and temperature in the sample has been a crucial objective, particularly for experiments that simulate the Earth's interior. However, in some cases using a thermocouple may have a high likelihood of failure or is incompatible with a high‐pressure assembly. To address these challenges and similar issues, we aim to expand a previously proposed solution: to jointly estimate pressure and temperature (〈italic〉PT〈/italic〉) through 〈italic〉in situ〈/italic〉 X‐ray diffraction, to cover a wider range of internal 〈italic〉PT〈/italic〉 calibrants tested over larger 〈italic〉PT〈/italic〉 ranges. A modifiable Python‐based software is offered to quickly obtain results. To achieve these aims, 〈italic〉in situ〈/italic〉 large volume press experiments are performed on pellets of intimately mixed powders of a halide (NaCl, KCl, KBr, CsCl) or MgO and a metal (Pt, Re, Mo, W, Ni) in the pressure range 3–11 GPa and temperature range 300–1800 K. Although the pressure range was chosen for practical reasons, it also covers an equally important depth range in the Earth (down to 350 km) for geoscience studies. A thermocouple was used to validate the 〈italic〉PT〈/italic〉 conditions in the cell assemblies. The key results show that choosing the appropriate calibrant materials and using a joint 〈italic〉PT〈/italic〉 estimation can yield surprisingly small uncertainties (〈italic〉i.e.〈/italic〉 〈±0.1 GPa and 〈±50 K). This development is expected to benefit current and future research at extreme conditions, as other materials with high compressibility or high thermal pressure, stable over large 〈italic〉PT〈/italic〉 ranges, may be discovered and used as 〈italic〉PT〈/italic〉 calibrants.〈/p〉
    Beschreibung: Research in high‐pressure devices, such as the diamond anvil cell and the large volume press, requires knowledge of the pressure and temperature in the sample. Here, a large volume press and an internal resistive heater were used to generate high load and heat to various combinations of intimately mixed powders of materials. X‐ray diffraction and custom software were used to jointly estimate the pressures and temperatures in the samples and establish calibrants for 〈italic〉in situ〈/italic〉 experiments at extreme conditions.〈boxed-text position="anchor" content-type="graphic" xml:lang="en"〉〈graphic position="anchor" id="jats-graphic-1" xlink:href="urn:x-wiley:16005775:jsy2vl5008:jsy2vl5008-fig-0001"〉
    Beschreibung: https://gitlab.desy.de/robert.farla/eoscross
    Schlagwort(e): ddc:548 ; equations of state ; X‐ray diffraction ; large volume press ; high pressure ; resistive heating
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 13
    Publikationsdatum: 2024-03-05
    Beschreibung: Full‐field X‐ray nanoimaging is a widely used tool in a broad range of scientific areas. In particular, for low‐absorbing biological or medical samples, phase contrast methods have to be considered. Three well established phase contrast methods at the nanoscale are transmission X‐ray microscopy with Zernike phase contrast, near‐field holography and near‐field ptychography. The high spatial resolution, however, often comes with the drawback of a lower signal‐to‐noise ratio and significantly longer scan times, compared with microimaging. In order to tackle these challenges a single‐photon‐counting detector has been implemented at the nanoimaging endstation of the beamline P05 at PETRA III (DESY, Hamburg) operated by Helmholtz‐Zentrum Hereon. Thanks to the long sample‐to‐detector distance available, spatial resolutions of below 100 nm were reached in all three presented nanoimaging techniques. This work shows that a single‐photon‐counting detector in combination with a long sample‐to‐detector distance allows one to increase the time resolution for in situ nanoimaging, while keeping a high signal‐to‐noise level.
    Beschreibung: A direct photon‐counting detector was used for different nanoimaging phase contrast techniques, increasing the temporal resolution.
    Schlagwort(e): ddc:548 ; nanotomography ; full‐field X‐ray microscopy ; near‐field holography ; near‐field ptychography ; Zernike phase contrast ; single‐photon‐counting detector ; phase contrast
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 14
    Publikationsdatum: 2024-02-14
    Beschreibung: Machine learning (ML) has received enormous attention in science and beyond. Discussed here are the status, opportunities, challenges and limitations of ML as applied to X‐ray and neutron scattering techniques, with an emphasis on surface scattering. Typical strategies are outlined, as well as possible pitfalls. Applications to reflectometry and grazing‐incidence scattering are critically discussed. Comment is also given on the availability of training and test data for ML applications, such as neural networks, and a large reflectivity data set is provided as reference data for the community.
    Beschreibung: The status, opportunities, challenges and limitations of machine learning are discussed as applied to X‐ray and neutron scattering techniques, with an emphasis on surface scattering.
    Schlagwort(e): ddc:548 ; surface scattering ; X‐ray diffraction ; neutron scattering ; machine learning ; data analysis
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 15
    Publikationsdatum: 2024-02-21
    Beschreibung: The storage ring upgrade of the European Synchrotron Radiation Facility makes ESRF–EBS the most brilliant high‐energy fourth‐generation light source, enabling in situ studies with unprecedented time resolution. While radiation damage is commonly associated with degradation of organic matter such as ionic liquids or polymers in the synchrotron beam, this study clearly shows that highly brilliant X‐ray beams readily induce structural changes and beam damage in inorganic matter, too. Here, the reduction of Fe3+ to Fe2+ in iron oxide nanoparticles by radicals in the brilliant ESRF–EBS beam, not observed before the upgrade, is reported. Radicals are created due to radiolysis of an EtOH–H2O mixture with low EtOH concentration (∼6 vol%). In light of extended irradiation times during insitu experiments in, for example, battery and catalysis research, beam‐induced redox chemistry needs to be understood for proper interpretation of insitu data.
    Beschreibung: With the increased brilliance at the European Research Facility–Extremely Brilliant Source (ESRF–EBS), a beam‐induced reduction of non‐stochiometric iron oxide nanoparticles (almost maghemite composition) to magnetite was observed in a mixture of ethanol and water with low ethanol concentration.
    Schlagwort(e): ddc:548 ; beam‐induced radiolysis ; radiation damage on inorganic materials ; ESRF–EBS
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 16
    Publikationsdatum: 2023-12-14
    Beschreibung: In Bragg coherent diffractive imaging, the precise location of the measured crystals in the interior of the sample is usually missing. Obtaining this information would help the study of the spatially dependent behavior of particles in the bulk of inhomogeneous samples, such as extra‐thick battery cathodes. This work presents an approach to determine the 3D position of particles by precisely aligning them at the instrument axis of rotation. In the test experiment reported here, with a 60 µm‐thick LiNi0.5Mn1.5O4 battery cathode, the particles were located with a precision of 20 µm in the out‐of‐plane direction, and the in‐plane coordinates were determined with a precision of 1 µm.
    Beschreibung: A method to determine the 3D position of particles in Bragg coherent diffractive imaging experiments is proposed. Test measurements demonstrate depth‐resolution with a precision of 20 µm along the beam. image
    Schlagwort(e): ddc:548 ; extra‐thick battery cathodes ; Bragg coherent X‐ray diffractive imaging ; battery cathodes ; Bragg diffraction ; sphere of confusion ; 3D mapping
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 17
    Publikationsdatum: 2024-01-12
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉〈italic〉XDSGUI〈/italic〉 is a lightweight graphical user interface (GUI) for the 〈italic〉XDS〈/italic〉, 〈italic〉SHELX〈/italic〉 and 〈italic〉ARCIMBOLDO〈/italic〉 program packages that serves both novice and experienced users in obtaining optimal processing and phasing results for X‐ray, neutron and electron diffraction data. The design of the program enables data processing and phasing without command line usage, and supports advanced command flows in a simple user‐modifiable and user‐extensible way. The GUI supplies graphical information based on the tabular log output of the programs, which is more intuitive, comprehensible and efficient than text output can be.〈/p〉
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉A customizable stateless graphical user interface simplifies the processing, analysis and phasing of diffraction data.〈boxed-text position="anchor" content-type="graphic" xml:lang="en"〉〈graphic position="anchor" id="jats-graphic-1" xlink:href="urn:x-wiley:16005767:jcr2yr5110:jcr2yr5110-fig-0001"〉 〈alt-text〉image〈/alt-text〉 〈/graphic〉〈/boxed-text〉〈/p〉
    Schlagwort(e): ddc:548 ; X‐ray diffraction ; neutron diffraction ; electron diffraction ; data processing ; graphical user interfaces ; phasing ; XDS ; ARCIMBOLDO ; SHELX
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 18
    Publikationsdatum: 2023-01-15
    Beschreibung: A Guinier camera equipped with an imaging plate is used to investigate and eliminate the sources of instrumental errors affecting the quality of the obtained scanned Guinier data. A program with a graphical user interface is presented which converts the data of the scanned images into different standard file formats for powder X‐ray patterns containing intensities, their standard deviations and the diffraction angles. The program also allows for manual and automatic correction of the 2gθ scale against a known reference material. It is shown using LaB6 that the exported X‐ray diffraction patterns provide a 2gθ scale reproducible enough to allow for averaging diffractograms obtained from different exposures of the imaging plate for the same sample. As shown on a mixture of NaCl and sodalite, the quality of the produced data is sufficient for Rietveld refinement. The software including source code is made available under a free software license.
    Beschreibung: A program for the digitization of Guinier powder diffraction images is described, which works with images from both optical and laser scanners. Thus, processing of data from storage‐phosphor‐based imaging plates and Ag‐based photographic films is possible.
    Schlagwort(e): ddc:548 ; IPreader software ; Guinier cameras ; imaging plates (IPs) ; diffraction pattern conversion into data columns ; powder X‐ray diffraction ; data processing ; Guinier method
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 19
    Publikationsdatum: 2023-07-04
    Beschreibung: Magnetic small‐angle neutron scattering (SANS) is ideally suited to providing direct reciprocal‐space information on long‐wavelength magnetic modulations, such as helicoids, solitons, merons or skyrmions. SANS of such structures in thin films or micro‐structured bulk materials is strongly limited by the tiny scattering volume vis a vis the prohibitively high background scattering by the substrate and support structures. Considering near‐surface scattering just above the critical angle of reflection, where unwanted signal contributions due to substrate or support structures become very small, it is established that the scattering patterns of the helical, conical, skyrmion lattice and fluctuation‐disordered phases in a polished bulk sample of MnSi are equivalent for conventional transmission and near‐surface SANS geometries. This motivates the prediction of a complete repository of scattering patterns expected for thin films in the near‐surface SANS geometry for each orientation of the magnetic order with respect to the scattering plane.
    Beschreibung: Near‐surface SANS is discussed for its potential as a probe of long‐wavelength magnetic modulations in specimens with reduced sample dimensions.
    Schlagwort(e): ddc:548 ; small‐angle neutron scattering ; near‐surface SANS ; magnetism ; non‐collinear magnetism ; thin films ; skyrmions ; MnSi
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 20
    Publikationsdatum: 2023-12-04
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉A way has been developed to measure the unit‐cell parameters of a single crystal just from an energy scan with X‐rays, even when the exact energy of the X‐rays is not well defined due to an error in the pitch angle of the monochromator. The precision of this measurement reaches 〈italic〉da〈/italic〉/〈italic〉a〈/italic〉 ∼ 1 × 10〈sup〉−5〈/sup〉. The method is based on the analysis of diffraction losses of the beam, transmitted through a single crystal (the so‐called `glitch effect'). This method can be easily applied to any transmissive X‐ray optical element made of single crystals (for example, X‐ray lenses). The only requirements are the possibility to change the energy of the generated X‐ray beam and some intensity monitor to measure the transmitted intensity. The method is agnostic to the error in the monochromator tuning and it can even be used for determination of the absolute pitch (or 2gθ) angle of the monochromator. Applying the same method to a crystal with well known lattice parameters allows determination of the exact cell parameters of the monochromator at any energy.〈/p〉
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉Diffraction losses (glitches) at certain energies of the X‐ray beam, transmitted through a single crystal, can be used for lattice parameters determination as well as for calibrating the monochromator (absolute pitch angle and the unit‐cell parameter).〈boxed-text position="anchor" content-type="graphic" xml:lang="en"〉〈graphic position="anchor" id="jats-graphic-1" xlink:href="urn:x-wiley:16005775:jsy2ay5590:jsy2ay5590-fig-0001"〉 〈alt-text〉image〈/alt-text〉 〈/graphic〉〈/boxed-text〉〈/p〉
    Schlagwort(e): ddc:548 ; X‐ray glitches ; diffraction losses ; unit‐cell parameter ; single‐crystal X‐ray optics ; monochromator calibration
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 21
    Publikationsdatum: 2023-07-21
    Beschreibung: Finite size effects in partial pair distribution functions generate artefacts in the scattering structure factor and scattering intensity. It is shown how they can be overcome using a binned version of the Debye scattering equation. Accordingly, reverse Monte Carlo simulations are used for very small nanoparticles of LaFeO3 with diameters below 10 nm to simultaneously analyse X‐ray scattering data and extended X‐ray absorption fine structure spectra at the La K and Fe K edges. The structural information obtained is consistent regarding local structure and long‐range order.
    Beschreibung: Computing scattering intensity using the Debye scattering equation after binning interatomic distances avoids finite size artefacts and is efficient enough for simultaneous refinement of scattering data and extended X‐ray absorption spectra by reverse Monte Carlo simulations.
    Schlagwort(e): ddc:548 ; extended X‐ray absorption fine structure ; EXAFS ; wide‐angle X‐ray scattering ; WAXS ; reverse Monte Carlo ; RMC ; nanocrystals ; LaFeO3
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 22
    Publikationsdatum: 2023-01-21
    Beschreibung: X‐ray diffraction with high spatial resolution is commonly used to characterize (poly)crystalline samples with, for example, respect to local strain, residual stress, grain boundaries and texture. However, the investigation of highly absorbing samples or the simultaneous assessment of high‐Z materials by X‐ray fluorescence have been limited due to the utilization of low photon energies. Here, a goniometer‐based setup implemented at the P06 beamline of PETRA III that allows for micrometre spatial resolution with a photon energy of 35 keV and above is reported. A highly focused beam was achieved by using compound refractive lenses, and high‐precision sample manipulation was enabled by a goniometer that allows up to 5D scans (three rotations and two translations). As experimental examples, the determination of local strain variations in martensitic steel samples with micrometre spatial resolution, as well as the simultaneous elemental distribution for high‐Z materials in a thin‐film solar cell, are demonstrated. The proposed approach allows users from the materials‐science community to determine micro‐structural properties even in highly absorbing samples.
    Beschreibung: A demonstration of high‐resolution micro X‐ray diffraction at high photon energies for highly absorbing samples.
    Schlagwort(e): ddc:548 ; X‐ray diffraction ; high spatial resolution ; high photon energy ; X‐ray fluorescence ; goniometers
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 23
    Publikationsdatum: 2023-01-21
    Beschreibung: This paper presents the Domain Auto Finder (DAFi) program and its application to the analysis of single‐crystal X‐ray diffraction (SC‐XRD) data from multiphase mixtures of microcrystalline solids and powders. Superposition of numerous reflections originating from a large number of single‐crystal domains of the same and/or different (especially unknown) phases usually precludes the sorting of reflections coming from individual domains, making their automatic indexing impossible. The DAFi algorithm is designed to quickly find subsets of reflections from individual domains in a whole set of SC‐XRD data. Further indexing of all found subsets can be easily performed using widely accessible crystallographic packages. As the algorithm neither requires a priori crystallographic information nor is limited by the number of phases or individual domains, DAFi is powerful software to be used for studies of multiphase polycrystalline and microcrystalline (powder) materials. The algorithm is validated by testing on X‐ray diffraction data sets obtained from real samples: a multi‐mineral basalt rock at ambient conditions and products of the chemical reaction of yttrium and nitrogen in a laser‐heated diamond anvil cell at 50 GPa. The high performance of the DAFi algorithm means it can be used for processing SC‐XRD data online during experiments at synchrotron facilities.
    Beschreibung: This paper presents the Domain Auto Finder (DAFi) program and its application to the analysis of single‐crystal X‐ray diffraction (SC‐XRD) data from multiphase mixtures of microcrystalline solids and powders. The DAFi algorithm is designed to quickly find subsets of reflections from individual domains in a whole set of SC‐XRD data and neither requires a priori crystallographic information nor is limited by the number of phases or individual domains.
    Schlagwort(e): ddc:548 ; single‐crystal domain auto finder ; DAFi ; single‐crystal X‐ray diffraction ; polycrystalline samples ; multiphase mixtures
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 24
    Publikationsdatum: 2024-02-14
    Beschreibung: X‐ray crystallography has witnessed a massive development over the past decade, driven by large increases in the intensity and brightness of X‐ray sources and enabled by employing high‐frame‐rate X‐ray detectors. The analysis of large data sets is done via automatic algorithms that are vulnerable to imperfections in the detector and noise inherent with the detection process. By improving the model of the behaviour of the detector, data can be analysed more reliably and data storage costs can be significantly reduced. One major requirement is a software mask that identifies defective pixels in diffraction frames. This paper introduces a methodology and program based upon concepts of machine learning, called robust mask maker (RMM), for the generation of bad‐pixel masks for large‐area X‐ray pixel detectors based on modern robust statistics. It is proposed to discriminate normally behaving pixels from abnormal pixels by analysing routine measurements made with and without X‐ray illumination. Analysis software typically uses a Bragg peak finder to detect Bragg peaks and an indexing method to detect crystal lattices among those peaks. Without proper masking of the bad pixels, peak finding methods often confuse the abnormal values of bad pixels in a pattern with true Bragg peaks and flag such patterns as useful regardless, leading to storage of enormous uninformative data sets. Also, it is computationally very expensive for indexing methods to search for crystal lattices among false peaks and the solution may be biased. This paper shows how RMM vastly improves peak finders and prevents them from labelling bad pixels as Bragg peaks, by demonstrating its effectiveness on several serial crystallography data sets.
    Beschreibung: Attention is focused on perhaps the biggest bottleneck in data analysis for serial crystallography at X‐ray free‐electron lasers, which has not received serious enough examination to date. An effective and reliable way is presented to identify anomalies in detectors, using machine learning and recently developed mathematical methods in the field referred to as `robust statistics'. image
    Schlagwort(e): ddc:548 ; bad‐pixel masks ; robust mask maker ; machine learning ; robust statistics ; serial crystallography
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 25
    facet.materialart.
    Unbekannt
    International Union of Crystallography | 5 Abbey Square, Chester, Cheshire CH1 2HU, England
    Publikationsdatum: 2024-02-22
    Beschreibung: Small‐angle scattering is an increasingly common method for characterizing particle ensembles in a wide variety of sample types and for diverse areas of application. SASfit has been one of the most comprehensive and flexible curve‐fitting programs for decades, with many specialized tools for various fields. Here, a selection of enhancements and additions to the SASfit program are presented that may be of great benefit to interested and advanced users alike: (a) further development of the technical basis of the program, such as new numerical algorithms currently in use, a continuous integration practice for automated building and packaging of the software, and upgrades on the plug‐in system for easier adoption by third‐party developers; (b) a selection of new form factors for anisotropic scattering patterns and updates to existing form factors to account for multiple scattering effects; (c) a new type of a very flexible distribution called metalog [Keelin (2016). Decis. Anal.13, 243–277], and regularization techniques such as the expectation‐maximization method [Dempster et al. (1977). J. R. Stat. Soc. Ser. B (Methodological), 39, 1–22; Richardson (1972) J. Opt. Soc. Am.62, 55; Lucy (1974). Astron. J.79, 745; Lucy (1994). Astron. Astrophys.289, 983–994], which is compared with fits of analytical size distributions via the non‐linear least‐squares method; and (d) new structure factors, especially for ordered nano‐ and meso‐scaled material systems, as well as the Ornstein–Zernike solver for numerical determination of particle interactions and the resulting structure factor when no analytical solution is available, with the aim of incorporating its effects into the small‐angle scattering intensity model used for fitting with SASfit.
    Beschreibung: Recent enhancements and additions to the SASfit program are discussed, including anisotropic scattering models, flexible distributions, regularization techniques such as the expectation‐maximization method, and new structure factors, especially for ordered nano‐ and meso‐scaled material. The Ornstein–Zernike solver for numerical structure factors is also introduced. image
    Schlagwort(e): ddc:548 ; small‐angle scattering ; SASfit ; numerical models ; structure factors ; form factors ; regularization techniques
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 26
    Publikationsdatum: 2024-02-05
    Beschreibung: A modulation of intensity with zero effort (MIEZE) setup is proposed for high‐resolution neutron spectroscopy at momentum transfers up to 3 Å〈sup〉−1〈/sup〉, energy transfers up to 20 meV and an energy resolution in the microelectronvolt range using both thermal and cold neutrons. MIEZE has two prominent advantages compared with classical neutron spin echo. The first is the possibility to investigate spin‐depolarizing samples or samples in strong magnetic fields without loss of signal amplitude and intensity. This allows for the study of spin fluctuations in ferromagnets, and facilitates the study of samples with strong spin‐incoherent scattering. The second advantage is that multi‐analyzer setups can be implemented with comparatively little effort. The use of thermal neutrons increases the range of validity of the spin‐echo approximation towards shorter spin‐echo times. In turn, the thermal MIEZE option for greater ranges (TIGER) closes the gap between classical neutron spin‐echo spectroscopy and conventional high‐resolution neutron spectroscopy techniques such as triple‐axis, time‐of‐flight and back‐scattering. To illustrate the feasibility of TIGER, this paper presents the details of its implementation at the RESEDA beamline at FRM II by means of an additional velocity selector, polarizer and analyzer.
    Beschreibung: A modulation of intensity with zero effort (MIEZE) setup is proposed for high‐resolution neutron spectroscopy at momentum transfers up to 3 Å〈sup〉−1〈/sup〉, energy transfers up to 20 meV and an energy resolution in the microelectronvolt range using both thermal and cold neutrons.
    Schlagwort(e): ddc:548 ; neutron resonant spin echo ; MIEZE ; quasielastic scattering ; thermal neutrons
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 27
    facet.materialart.
    Unbekannt
    International Union of Crystallography | 5 Abbey Square, Chester, Cheshire CH1 2HU, England
    Publikationsdatum: 2023-12-12
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉Studying electron‐ and X‐ray‐induced electron cascades in solids is essential for various research areas at free‐electron laser facilities, such as X‐ray imaging, crystallography, pulse diagnostics or X‐ray‐induced damage. To better understand the fundamental factors that define the duration and spatial size of such cascades, this work investigates the electron propagation in ten solids relevant for the applications of X‐ray lasers: Au, B〈sub〉4〈/sub〉C, diamond, Ni, polystyrene, Ru, Si, SiC, Si〈sub〉3〈/sub〉N〈sub〉4〈/sub〉 and W. Using classical Monte Carlo simulation in the atomic approximation, we study the dependence of the cascade size on the incident electron or photon energy and on the target parameters. The results show that an electron‐induced cascade is systematically larger than a photon‐induced cascade. Moreover, in contrast with the common assumption, the maximal cascade size does not necessarily coincide with the electron range. It was found that the cascade size can be controlled by careful selection of the photon energy for a particular material. Photon energy, just above an ionization potential, can essentially split the absorbed energy between two electrons (photo‐ and Auger), reducing their initial energy and thus shrinking the cascade size. This analysis suggests a way of tailoring the electron cascades for applications requiring either small cascades with a high density of excited electrons or large‐spread cascades with lower electron densities.〈/p〉
    Beschreibung: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉Studying electron‐ and X‐ray‐induced electron cascades in solids is essential for various research areas at free‐electron laser facilities, such as X‐ray imaging, crystallography, pulse diagnostics or X‐ray‐induced damage. To better understand the fundamental factors that define the duration and spatial size of such cascades, this work investigates the electron propagation in ten solids relevant for the applications of X‐ray lasers. Using classical Monte Carlo simulation in the atomic approximation, the dependence of the cascade size on the incident electron or photon energy and on the target parameters is studied.〈boxed-text position="anchor" content-type="graphic" xml:lang="en"〉〈graphic position="anchor" id="jats-graphic-1" xlink:href="urn:x-wiley:16005775:jsy2gb5123:jsy2gb5123-fig-0001"〉 〈/graphic〉〈/boxed-text〉〈/p〉
    Schlagwort(e): ddc:548 ; electron cascades ; X‐ray free‐electron lasers ; Monte Carlo ; photon‐induced cascade ; electron transport
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 28
    Publikationsdatum: 2024-03-13
    Beschreibung: The PERCIVAL detector is a CMOS imager designed for the soft X‐ray regime at photon sources. Although still in its final development phase, it has recently seen its first user experiments: ptychography at a free‐electron laser, holographic imaging at a storage ring and preliminary tests on X‐ray photon correlation spectroscopy. The detector performed remarkably well in terms of spatial resolution achievable in the sample plane, owing to its small pixel size, large active area and very large dynamic range; but also in terms of its frame rate, which is significantly faster than traditional CCDs. In particular, it is the combination of these features which makes PERCIVAL an attractive option for soft X‐ray science.
    Schlagwort(e): ddc:548 ; X‐ray detectors ; soft X‐rays ; ptychography ; holographic imaging ; XPCS ; detectors
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 29
    Publikationsdatum: 2023-07-19
    Beschreibung: Raman spectroscopy has been widely used in mineralogy and petrology for identifying mineral phases. Some recent applications of Raman spectroscopy involve measuring the residual pressure of mineral inclusions, such as quartz inclusions in garnet host, to recover the entrapment pressure condition during metamorphism. The crystallographic orientations of entrapped inclusions and host are important to know for the modelling of their elastic interaction. However, the analysis of tiny entrapped mineral inclusions using EBSD technique requires time consuming polishing. The crystallographic orientations can be measured using polarized Raman spectroscopy, as the intensities of Raman bands depend on the mutual orientation between the polarization direction of the laser and the crystallographic orientation of the crystal. In this study, the Raman polarizability tensor of quartz is first obtained and is used to fit arbitrary orientations of quartz grains. We have implemented two rotation methods: (1) sample rotation method, where the sample is rotated on a rotation stage, and (2) polarizer rotation method, where the polarization directions of the incident laser and the scattered Raman signal are parallel and can be rotated using a circular polarizer. The precision of the measured crystallographic orientation is systematically studied and is shown to be ca. 0.25 degrees using quartz wafers and quartz plates that are cut along known orientations. It is shown that the orientation of tiny mineral inclusions (ca. 2–5 μm) can be precisely determined and yield consistent results with EBSD.
    Beschreibung: Alexander von Humboldt-Stiftung http://dx.doi.org/10.13039/100005156
    Beschreibung: Deutsche Forschungsgemeinschaft http://dx.doi.org/10.13039/501100001659
    Beschreibung: Freie Universität Berlin (1008)
    Schlagwort(e): ddc:548 ; Raman spectroscopy ; Elastic thermobarometry ; Crystallographic orientation ; Quartz ; Inclusion
    Sprache: Englisch
    Materialart: doc-type:article
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...