    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 31-35 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface deactivation, silylation ; Inertia stable to 350° ; Free acids and bases, simultaneous injection ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A deactivation procedure is described based on a published method using hexamethyldisilazane in the gas phase. In addition to unusually high inertia and thermostability, the method produces truly neutral columns which allow simultaneous analysis of moderately strong free acids and bases. The silylated columns show their full potential only with on-column injection. Preliminary experimental directions are given; more elaborate directions will become available after extended optimization work.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 343-350 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Analysis up to C50 in GC/quadrupole MS combination ; No special procedures necessary when using commercially available instruments ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The analysis of low volatile compounds by (GC)2/MS using high-temperature stable glass-capillary columns and a commercially available GC/quadrupole MS instrument is described.It will be shown that no special modifications or procedures are required in analyzing organic compounds exceeding carbon numbers of 50. The application to industrially and naturally occuring high boiling mixtures will be discussed.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 351-356 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Potash soda lead and fused silica as wall material investigated ; Thin-walled fused silica is an ideal material ; Inherently more inert than normal glass ; High flexibility avoids fragility problems ; Application examples (alcohols, mercaptanes, sulfides, phenolsamines, acids) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An investigation was conducted of various glasses, other than soda lime or borosilicate, for use in glass capillary gas chromatography. The work has uncovered some unique chromatographic qualities in the use of potash soda lead and fused silica glasses as materials for making glass capillary columns. The fused silica proved to be an ideal material for capillary column construction, being inherently more inert than glass containing metal oxides. It has been shown that through the use of thin wall capillary tubing of high flexibility many of the mechanical problems associated with glass capillary columns, such as fragility and column straightening, can be avoided.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 405-410 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Stationary phases of polysiloxane-type degrade in acidic solution ; Several salt traces affect stability at high temperature NaCl on Duran-5O: no effect at 260°C ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A number of polysiloxanes have been shown to be sensitive to acids when dissolved in chloroform.At 26O°C polysiloxanes were found to degrade under the influence of several compounds used or produced during the preparation of glass capillary columns.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface roughening by direct deposition of suspension particles ; NaCl used ; High reproducibility when coated with polar phases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for roughening the surface of glass capillary columns for subsequent coating with polar stationary phases. A suspension of sodium chloride, obtained by addition of a saturated solution of sodium chloride in methanol to 1,1,1-trichloroethane, is passed through the column at velocities of 1-5 cm/s. During passage of the suspension, particles of sodium chloride deposit spontaneously on the column wall. The amount of sodium chloride deposited on the column wall is a function of the volume of the suspension passed through and of the contact time of the suspension and the column wall. Ultimately the amount of sodium chloride per unit surface area approaches a maximum. Columns covered with this maximum amount of sodium chloride were prepared with high reproducibility and coated with a number of polar stationary phases. Various factors that influence the stability of the suspension and the deposition of sodium chloride are discussed and minimum requirements are given. A theoretical model is proposed for the mechanism of deposition of sodium chloride particles on the glass wall.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 577-578 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; support and packing production technique and device ; drying, removal of fines, silanization, solution coating, total evaporation ; in one system ; normal transport results in partial mechanical partlkel damage, causing tailing, decomposition on uncoated surfaces ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 749-750 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Packed column, glass ; Dichloroacetic acid ; In biological fluids, at 50 ng level ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method for the measurement of dichloroacetic acid in plasma or urine has been developed. The method involves extraction of dichloroacetic acid into diethyl ether, evaporation of the etheric phase to a small volume and derivatization with diazomethane. Trichloroacetic acid was used as an internal standard. Concentrations as low as 50 ng/ml can be determined.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 187-188 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Whiskers, OV-17 ; Steroid profiling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 444-446 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Micropacked columns ; Sample capacity under comparable conditions forty times larger than in capillaries ; Equations given ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Equations have been derived from which the maximum sample size which may be loaded on a column without significantly affecting the performance may be calculated. It is shown that micro-packed columns can handle a sample which is as much as forty times larger than that which can be loaded onto wall-coated open tubular columns with comparable conditions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 481-486 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Splitting conditions for quantitative sampling investigated ; Injection amount and temperature should remain constant ; Standard deviation below 1% ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Sample inlet splitters are used in capillary column gas chromatography. We have investigated the sample band broadening in the splitter and studied reproducibility and accuracy in quantitative analysis using a simple lab-made splitter. It was found that the results were dependent upon the operating conditions such as split ratio, splitter temperature, glass wool plug, injected sample volume and solvent.
    Additional Material: 7 Ill.