ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chromatographie, Gas  (24)
  • Springer  (24)
  • 1995-1999
  • 1980-1984
  • 1975-1979  (24)
  • 1978  (24)
Collection
Publisher
  • Springer  (24)
Years
  • 1995-1999
  • 1980-1984
  • 1975-1979  (24)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 114-114 
    ISSN: 1618-2650
    Keywords: Best. von Ameisensäure in Harn ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 158-158 
    ISSN: 1618-2650
    Keywords: Best. von Doxepin, Desmethyldoxepin in Plasma ; Chromatographie, Gas ; cis-trans-Isomere
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 155-155 
    ISSN: 1618-2650
    Keywords: Best. von Schlafmitteln in Serum ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 132-133 
    ISSN: 1618-2650
    Keywords: Best, von α-Ketosäuren ; Chromatographie, Gas ; N-selektiver Detektor
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 291 (1978), S. 299-307 
    ISSN: 1618-2650
    Keywords: Analyse von Kohlenwasserstoffen in Luft ; Chromatographie, Gas ; Tieftemperaturgradientenrohr
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird über ein gas-chromatographisches Verfahren zur Bestimmung von Alkanen, Alkenen und Aromaten in der Außenluft berichtet, bei dem die Probenahme an Tenax GC oder Carbopack mit Hilfe eines Tieftemperaturgradientenrohres erfolgt und die Analyse unter Einsatz eines Doppelsäulensystems in Verbindung mit zwei Flammenionisationsdetektoren durchgeführt wird. Eingehende Untersuchungen zum Verhalten der Substanzen bei der Probenahme zeigen, daß die Trocknung der Probeluft mit Magnesiumperchlorat das Ergebnis nicht beeinflußt und für Kohlenwasserstoffe mit drei oder mehr C-Atomen keine auf Durchbruch zurückzuführenden Substanzverluste zu befürchten sind. Bei einem Probenahmevolumen von 51 Luft können 2 μg Substanz/m3 gut bestimmt werden. Für Außenluft-Konzentrationen von 45 μg Benzol/m3, 95 μg Toluol/m3 und 35 μg n-Pentan/m3 betrugen die Standardabweichungen 3,5, 6,0 bzw. 3,6 μg/m3. Bei leichter Modifikation des Systems ist mit derselben Probenahmevorrichtung die gleichzeitige Bestimmung von Kohlenwasserstoffen mit einem Flammenionisationsdetektor und von Organohalogen Verbindungen mit einem Elektroneneinfangdetektor möglich.
    Notes: Summary A method is described for the gas-chromatographic determination of alkanes, alkenes and aromatics in ambient air. The hydrocarbons are trapped by cryogenic sampling using Tenax GC or Carbopack as adsorbing material and are analyzed in a two-column system equipped with two flame-ionization detectors. A detailed examination of the sampling procedure shows that drying the air with magnesium perchlorate does not affect the results, and losses of substances due to break-through need not be reckoned with for hydrocarbons with three and more carbon atoms. In a 51 air sample 2 μg/m3 of hydrocarbons can be determined readily. The standard deviations for benzene, toluene and n-pentane were 3.5, 6.0 and 3.6 μg/m3 at ambient air concentrations of 45, 95 and 35 μg/m3. A slight modification of the system which includes the combined use of a flame-ionization detector and an electron-capture detector permits the simultaneous determination of hydrocarbons and halogenated hydrocarbons.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 97-107 
    ISSN: 1618-2650
    Keywords: Best. von Biphenylen, polychlorierte, Pesticide, chlorhaltig in Fisch ; Chromatographie, Gas ; Capillar, Persistenz
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Besides 83 structurally defined trichloro- to octachloro-biphenyls (PCB), the following chlorinated pesticides have been identified in fish liver oil (DAB 6) and fish liver extracts: HCB;α-HCH;γ-HCH; 2,4′-DDE; 4,4′-DDE; 2,4′-DDT; 4,4′-DDT; 2,4′-DDD; 4,4′-DDD; dieldrin; endrin. By analysing constant relative amounts of PCB-components present only in defined technical PCB-mixtures, the original PCB-pattern in environmental samples could be calculated. A mixture of Clophen A 60/Clophen A50 or of Aroclor 1260/Aroclor 1254 of 2.2∶1 gives the best fit. The constant ratio of four octachloro-biphenyls in technical mixtures and environmental samples as well requires the assumption of complete environmental stability of these compounds despite of any thinkable differences in environmental pathways. This assumption of environmental persistency is supported by a degree of degradation up to 80% of the calculated input observed for some higher chlorinated PCB-components, e.g. 2,2′,3,4,5′,6-hexachloro-biphenyl. Correlating the amount of each identified PCB-component to the octachloro-biphenyl as the internal standard, a correlation of the degradation with the PCB-substitution pattern is possible. Persistency is observed, if vicinal hydrogens are missing or a 4-position is chlorinated. A 4,4′-disubstitution favours persistency most.
    Notes: Zusammenfassung Neben 83 strukturell definierten Trichlor- bis Octachlor-biphenylen (PCB) wurden folgende chlorierte Biocide in Lebertran (DAB6) und Fischleberextrakten identifiziert: HCB;α-HCH;γ- HCH; 2,4′-DDE; 4,4′-DDE; 2,4′-DDT; 4,4′-DDT; 2,4′-DDD; 4,4′-DDD; Dieldrin; Endrin. Aus den Verhältnissen von nur in PCB-Produkten mit bestimmtem Chlorierungsgrad vorkommenden, schwer abbaubaren PCB-Komponenten konnte die ursprünglich in die Umwelt gelangte Zusammensetzung der PCB berechnet werden: eine Mischung aus Aroclor 1260/Aroclor 1254 (Monsanto, USA) oder Clophen A 60/Chlophen A 50 (Bayer, Deutschland) im Verhältnis 2,2∶1 ergibt die beste Näherung. Aus dem in technischen Produkten und den Umweltproben gleichen relativen Vorkommen von vier Octachlor-biphenylen muß auf deren völlige Stabilität unter Umweltbedingungen geschlossen werden. Diese Annahme wird durch den Abbau von bis zu 80% des ursprünglichen Gehalts anderer hochchlorierter Biphenyle, wie des 2,2′,3,4,5′,6-Hexachlor-biphenyls, gestützt. Wird das Vorkommen der identifizierten Chlorbiphenyle, auf die als persistent angenommenen Octachlor-biphenyle als internen Standard bezogen, ergibt sich eine klare Persistenz-Abbau-Beziehung zu dem PCB-Substitutionsmuster. Persistenz ist gegeben bei fehlenden vicinalen Wasserstoffatomen oder 4-Chlorsubstitution, wobei die 4,4′-Di-Substitution die Persistenz am stärksten fördert.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 211-219 
    ISSN: 1618-2650
    Keywords: Analyse von Metallen mit Dialkyldithiocarbamaten ; Chromatographie, Gas ; Eigenschaften, Extinktionskoeff., Dampfdrucke der Chelate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Darstellung, Eigenschaften, Extinktionskoeffizienten, thermogravimetrisches Verhalten und Dampfdrucke einer Reihe von Dialkyldithiocarbamatochelaten werden beschrieben und die Möglichkeiten zu ihrer gas-chromatographischen Bestimmung umrissen.
    Notes: Summary Preparation, properties, extinction coefficients, thermogravimetric behaviour and vapour pressure are reported of various dialkyldithiocarbamato chelates. Possibilities for their gas-chromatographic determination are outlined.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 290-294 
    ISSN: 1618-2650
    Keywords: Best. von Zink, Kupfer, Nickel mit Dipropyldithiocarbamat ; Chromatographie, Gas ; Extraktion aus wäßr. Lösung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Kleine Mengen Ni, Cu und Zn in wäßrigen Lösungen können nach Ausschütteln ihrer Dipropyldithiocarbamatochelate gas-chromatographisch bestimmt werden. Arbeitsbedingungen für den 0,01–1 ppm-Bereich werden angegeben. Die Reproduzierbarkeit der Bestimmung wird durch Zusatz eines inneren Standards verbessert.
    Notes: Summary Small amounts of Ni, Cu and Zn in aqueous solutions can be determined by gas chromatography after extraction of their dipropyldithiocarbamatochelates. Working details for the 0.01–1 ppm range are reported. Reproducibility is markedly improved by addition of an inner standard.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 303-304 
    ISSN: 1618-2650
    Keywords: Best. von Nimetazepam in biolog. Material ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 289 (1978), S. 91-95 
    ISSN: 1618-2650
    Keywords: Analyse von Kohlenwasserstoffen, polycycl. in Klärschlamm ; Chromatographie, Gas ; Profilanalyse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein einfaches und selektives Anreicherungsverfahren für polycyclische aromatische Verbindungen angegeben (flüssig-flüssig-Verteilung: Dimethylformamid + Wasser + Cyclohexan; Chromatographie an Sephadex LH 20/Isopropanol; Filtration an Aluminiumoxid/Cyclohexan). Das Gemisch der polycyclischen aromatischen Kohlenwasserstoffe (= PAH) wird gas-chromatographisch an gepackten Hochleistungssäulen getrennt und die FID-Signale mit einem anfangs zugegebenen inneren Standard verglichen. Es wurden 18 Hauptkomponenten quantitativ ausgewertet. Die Variationskoeffizienten einer fünffachen Bestimmung derselben Probe lagen zwischen 1,6 und 11,3%. Die Nachweisgrenze des Verfahrens beträgt bei einer mittleren elektronischen Signalverstärkung in Abhängigkeit von der Retentionszeit 0,5–5 ng (für Benzo(a)pyren 1 ng). Die Charakterisierung der PAH mit 4–7 Ringen erfolgte mit einer GC-MS-Kombination, was für den Routinebetrieb aufgrund der großen Ähnlichkeit der PAH-Profile verschiedener Klärschlammproben nicht erforderlich ist.
    Notes: Summary A simple and selective method of enrichment of polycylic aromatic compounds is described (liquid-liquid-distribution with DMF + water + Cyclohexane; chromatography on Sephadex LH 20/isopropanol; filtration on aluminium oxide/cyclohexane). The fraction of polycyclic aromatic hydrocarbons (= PAH), separated gas-chromatographically using high performance columns, is evaluated by comparising the FID-signals with those of the internal standard added to the sample. Eightteen main components are evaluated. The variation coefficient of five analyses of the sample is in the range of 1.6–11.3%. The detection limit by moderate amplification depends on retention time of the PAH (0.5–5 ng; for benzo(a)pyrene 1 ng). As the PAH profiles of different samples of sludge are very similar, it is normally not necessary to characterize the PAH by mass spectrometry.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 113-113 
    ISSN: 1618-2650
    Keywords: Best. von Methylquecksilber in Blut ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1618-2650
    Keywords: Analyse von Polycycl. Verbindungen, Carbazole, Acridine ; Chromatographie, Gas ; Carcinogene
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 236-236 
    ISSN: 1618-2650
    Keywords: Analyse von Dimethylterephthalat ; Chromatographie, Gas ; Oxidationsgemisch
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 39-42 
    ISSN: 1618-2650
    Keywords: Analyse von Metaboliten in Biolog. Material ; Chromatographie, Gas ; Fraktionierung durch Extraktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A new method for the gas-chromatographic multicomponent analysis of metabolites in biological material is described. It is an analytical procedure involving several extractions carried out under different conditions. In this procedure the metabolites are divided according to their functional groups and specific chemical behaviours into eight main fractions: lipids, hydrocarbons, organic acids, neutral substances, phenols, amines, amino acids and carbohydrates. Each of these fractions is derivatized; the components are separated and estimated by gas chromatography. This analytical system was applied to the determination of a number of metabolites in serum, urine, amniotic fluid, sperma, tissues and other biological materials.
    Notes: Zusammenfassung Eine Methode für die Multikomponenten-GC-Analyse von Metaboliten in Biomaterialien wird beschrieben. Das Verfahren umfaßt mehrere Extraktionen, die unter verschiedenen Bedingungen durchgeführt werden. Die Komponenten werden in Abhängigkeit von ihren funktionellen Gruppen und spezifischem chemischen Verhalten in acht Hauptfraktionen geteilt: Lipide, Kohlenwasserstoffe, organische Säuren, neutrale Substanzen, Phenole, Amine, Aminosäuren und Kohlenhydrate. Die Komponenten jeder Gruppe werden nach spezieller Derivatisierung gaschromatographisch getrennt und bestimmt. Dieses neue System ist bei verschiedenen biologischen Materialien (klinische Proben, Pflanzen- und Tiergewebe) angewandt worden.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 412-413 
    ISSN: 1618-2650
    Keywords: Analyse von Dimethylterephthalat in Wasser ; Chromatographie, Gas ; Abwasser
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 1618-2650
    Keywords: Analyse von Umweltmaterial, Pesticiden ; Chromatographie, Gas ; Capillar-, Ident. von Einzelkomponenten in komplexen Gemischen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Der Vergleich von präzise bestimmten Retentionsindices von Probe- und Referenzsubstanzen in der hochauflösenden Capillar-Gas-Chromatographie stellt eine aussagekräftige Methode der Identifizierung von Einzelkomponenten in komplexen Gemischen dar. Neben der Konstanz der GC-Parameter erfordert die präzise Bestimmung von Retentionsindices eine sehr genaue Bestimmung der Netto-Retentionszeiten. Insbesondere ist bei Anwendung einer Totzeitberechnung auf der Basis einer erzwungenen Linearisierung der log t s/Homologenzahl-Beziehung auf eine sehr genaue Retentionszeitmessung zu achten. Die Reproduzierbarkeit von präzise bestimmten Retentionsindices hängt von der Konstanz der Polarität und von der Adsorptivität der Capillarsäule ab. An ausreichend desaktivierten und konditionierten Hochleistungs-Capillarsäulen (TZ≥40) können unter der Voraussetzung einer Retentionszeit-Meßgenauigkeit von besser als 0,05% Retentionsindices über einen Zeitraum von mehreren Wochen innerhalb ±0,15 Indexeinheiten reproduziert werden. Eine Übertragung des n-Alkan bezogenen Retentionsindex-Konzeptes auf die homologe Reihe der n-Allkyl-trichloracetate (ATA) ermöglicht die Verwendung des Elektroneneinfang-Detektors (ECD) zur präzisen RetentionsindexBestimmung als Methode einer zuverlässigen Identifizierung von Substanzen im Picogrammbereich.
    Notes: Summary High resolution glass-capillary gas chromatography can be used as a powerful identification tool for single components in complex mixtures, when the matching of retention indices of reference compounds with those found in the sample is based on precise measurements. Besides the constancy of the GC-parameters high precision measurements of retention indices require an accurate determination of net retention times. Special care has to be taken for an accurate measurement of retention times when using a dead-time calculation on the basis of an enforced linearisation of the log t s/homologues-number relationship. The reproducibility of precise retention-index determinations strongly depends on the constancy of the polarity and on the adsorptivity of the capillary column. Provided a sufficiently deactivated and conditioned high performance capillary column (separation number ≥40) and an accuracy of retention-time measurement of better than 0,05 % retention indices can be reproduced within ±0.15 i.u. over a period of several weeks. A conversion of the n-alkane based retention-index concept to the use of the homologous series of n-alkyl-trichloro-acetates (ATA) allows the use of the electron-capture detector (ECD) for precise retention-index determinations for a reliable identification of compounds in the picogram range.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 289 (1978), S. 287-288 
    ISSN: 1618-2650
    Keywords: Best. von Phenylbutazon, Oxyphenbutazon in Plasma, Harn ; Chromatographie, Gas ; Pferde
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 316-316 
    ISSN: 1618-2650
    Keywords: Best. von Dimethylchlorsilan in Trichlorsilan ; Chromatographie, Gas ; Chlorierung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 199-202 
    ISSN: 1618-2650
    Keywords: Verhalten von Di(trifluoroäthyl)dithiocarbamatochelaten ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Das gas-chromatographische Verhalten einiger Di(trifluoäthyl)dithiocarbamatochelate unter isothermen und temperaturprogrammierten Arbeitsbedingungen verschiedener Säulen wird beschrieben. Multielementanalyse von bis zu wenigstens neun Elementen dürfte auch nach Ausschütteln aus wäßrigen Lösungen möglich sein.
    Notes: Summary Gas chromatographic behaviour of some di(trifluoroethyl)dithiocarbamatochelates is investigated under isothermal and temperature programmed working conditions of various columns. Multielemental analysis of up to at least nine elements seems to be possible even after extraction out of aqueous solutions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 216-218 
    ISSN: 1618-2650
    Keywords: Best. von Pharmazeut. Produkten im Harn ; Chromatographie, Gas ; Extrelut, saure u. neutrale Stoffe
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zum gas-chromatographischen Nachweis saurer und neutraler Arzneistoffe wurden Harnproben bei pH 6 an Extrelut® (Merck) mit Diäthyläther extrahiert. Die Wiederfindungsraten der meisten untersuchten Arzneistoffe liegen im gleichen Bereich wie bei der üblichen Flüssig-Flüssig-Extraktion im stärker sauren Milieu. Jedoch verbleiben endogene Carbonsäuren, welche die Auswertung der Chromatogramme erschweren, in der wäßrigen Phase.
    Notes: Summary Samples of urine at pH 6 were extracted with diethyl ether from Extrelut® (Merck) columns for the gas-chromatographic identification of acidic and neutral drugs. The recovery rates for most of the investigated substances were similar to those of usual liquid-liquid extraction from strongly acidic media. Endogenous carboxylic acids however, which would otherwise interfere in the chromatogram, remained in the aqueous phase.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 111-112 
    ISSN: 1618-2650
    Keywords: Best. von Pentachlorphenol in Plasma, Urin ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 11-15 
    ISSN: 1618-2650
    Keywords: Best. von Blei neben Wismut ; Chromatographie, Gas ; Di(trifluoräthyl)dithiocarbamat. — Verhalten von Kupfer(II), Nickel(II), Kobalt(III), Eisen(III), Wismut(III), Blei(II), Antimon(III) ; Verteilung zwischen wäßriger Lösung und Chloroform
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Das Verteilungsverhalten der oben genannten Di(trifluroäthyl)dithiocarbamato-Chelate zwischen wäßrigen Lösungen und Chloroform wird untersucht. Eine Anwendung zur gleichzeitigen gaschromatographischen Bestimmung von Blei und Wismut im ppm-Bereich (0,2–3 ppm) nach Ausschütteln aus wäßrigen Lösungen wird beschrieben (Säule: 5 % GE SE50 auf Gas Chrom Q; 180–240° C; 4°/min; Einspritzblock: 240° C).
    Notes: Summary The solvent extraction of the above di(trifluoroethyl)dithiocarbamatochelates with chloroform is investigated. An application for the simultaneous gas-chromatographic determination 0.2–3 ppm of lead and bismuth after extraction out of aqueous solutions is reported (column: 5% GE SE 50 on Gas Chrom Q; 180–240° C; 4°/min; injection block: 242°C).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 207-212 
    ISSN: 1618-2650
    Keywords: Analyse von Carbiden in Aluminium, Magnesium ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A quantitative gas-chromatographic method (molecular sieve column, FID) for the determination of Al4C3 in aluminium and magnesium has been developed. The effect of methane from external sources has been investigated and eliminated. Metallographic analysis of carbides in polished specimens were consistent with the gas-chromatographic measurements within a factor of 2. The discrepancy can be explained by the large uncertainties in light microscopy analysis of the small carbides. Analysis of commercial magnesium shows that the metal contains ca. 2–9 ppm of Al4C3. The concentration of carbides in aluminium from the electrolysis cell is in the range of 10–35 ppm and in the final product of ca. 2–12 ppm Al4C3. CaC2 has been detected in a few magnesium and aluminium samples by means of gas-chromatography and microprobe analysis.
    Notes: Zusammenfassung Zur Bestimmung von Al4C3 in Aluminium und Magnesium wurde eine quantitative gas-chromatographische Methode (MolekularsiebSäule, FID) entwickelt. Der Einfluß von Methan aus äußeren Quellen, wurde untersucht und ausgeschaltet. Die metallographischen Untersuchungen von Carbiden an polierten Proben stimmten mit den Ergebnissen der gas-chromatographischen Messungen mit einem Faktor von 2 überein. Der Unterschied kann durch die großen Unsicherheiten bei der lichtmikroskopischen Analyse der kleinen Carbide erklärt werden. Die Analyse des technisch reinen Magnesiums zeigt, daß das Metall ca. 2–9 ppm Al4C3 enthält. Die Konzentration von Carbiden in elektrolytisch raffiniertem Aluminium liegt im Bereich 10–35 ppm und im Endprodukt bei ca. 2–12 ppm Al4C3. CaC2 wurde in einigen Magnesium- und Aluminiumproben mit Hilfe von gas-chromatographischen und Mikrosondenuntersuchungen festgestellt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 385-390 
    ISSN: 1618-2650
    Keywords: Best. von Carbonsäuren, Sulfonsäuren ; Chromatographie, Gas ; Spuren in wäßrigem Medium
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Gas-chromatographische Methoden für die Spurenbestimmung einiger Carbonund Sulfonsäuren in wäßrigem Medium werden beschrieben. Die Nachweisvermögen für Ameisensäure, Essigsäure, Propionsäure, n-Buttersäure, n-Valeriansäure, Capronsäure, Acrylsäure, Benzoesäure und Chloressigsäure sowie für Methansulfonsäure und Äthansulfonsäure liegen zwischen 1 · 10−7 und 8 · 10−7 Mol/Liter. Anreicherung und Derivatisierung werden bei den Carbonsäuren durch Gefriertrocknung der Tetra-n-butylammoniumsalze und deren Umsetzung mit Benzylbromid zu den Benzylestern, bei den Sulfonsäuren durch Gefriertrocknung der Silbersalze und deren Umsetzung mit n-Butyljodid zu den n-Butylestern erreicht.
    Notes: Summary Gas-chromatographic methods for the determination of traces of several carboxylic and sulphonic acids in aqueous media are presented. Detection limits for formic, acetic, propionic, n-butyric, isobutyric, n-valeric, caproic, acrylic, benzoic, and chloroacetic acids as well as of methanesulphonic and ethanesulphonic acids range from 1 · 10−7 moles/liter to 8 · 10−7 moles/liter. Preconcentration and derivatisation of the carboxylic acids are achieved by freezedrying their tetra-n-butylammonium salts and converting the latter into the benzyl carboxylates using benzyl bromide. The sulphonic acids are converted to the corresponding silver salts, freeze-dried, and then esterified using n-butyl iodide.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...