ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (902)
  • Analytical Chemistry and Spectroscopy  (902)
  • 1985-1989  (902)
  • 1986  (902)
Collection
  • Articles  (902)
Publisher
Years
  • 1985-1989  (902)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 154-160 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Ion mobility detection ; Tunable, selective detection ; Fourier transform-ion mobility spectrometry ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Using a unidirectional flow ion mobility detector, non-selective detection, tunable selective detection, and complete Fourier transformed ion mobility spectra were successfully obtained after supercritical fluid chromatography on compounds with higher molecular weights than have been previously investigated. In the most selective mode, single oligomers from polymeric material could be independently detected. Using the Fourier transform capabilities of this instrument, complete ion mobility spectra for each oligomer could be obtained in a single chromatographic separation. The collection of individual ion mobility spectra of the components of polymeric material has not been possible prior to the technique described in this paper. Only complex ion mobility spectra of polymeric mixtures are available in the literature. The spectra obtained in this study are all simple, uncomplicated spectra consisting of only one or two product ion peaks. Ko values reported in this work range from 0.633 to 1.61, which are some of the lowest values ever reported in ion mobility spectrometry.With the unidirectional flow design of the detector, the supercritical fluid mobile phase, carbon dioxide, was efficiently eliminated from the detector so that the ion mobility spectrometer could be operated in its normal manner. The fact that CO2 did not interfere with normal ion mobility operation indicates that other supercritical fluids may also be compatible with this sensitive and versatile detection method.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 186-187 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 89-94 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Capillary columns ; Mass spectrometry ; Autoderivatization ; Cyclophosphamide ; 4-Ketocyclophosphamide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The selectivity of a capillary gas chromatographic assay for the anti-neoplastic and immunosuppressive agent cyclophosphamide (CPA) towards one of its naturally occurring metabolites, i.e. 4-ketocyclophosphamide (4-keto CPA), has been studied. Mass spectrometry studies showed that a cyclization product of 4-keto-CPA can form using the same chromatographic conditions as those under which CPA was determined. However, the amount produced is relatively small (less than 10%) compared with the percentage produced from CPA. Furthermore, both cyclization products, formed by loss of HCI and intraalkylation of the parent compounds, can be separated well under suitable chromatographic conditions.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 300-301 
    ISSN: 0935-6304
    Keywords: Reversed phase high performance liquid chromatography, RP-HPLC ; Transition metal ions ; EDTA as complexing agent ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 308-309 
    ISSN: 0935-6304
    Keywords: High performance liquid chromatography, HPLC ; Reverse phase ; Internal standard ; Trimellitic anhydride ; Air sample ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 194-197 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986) 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 213-217 
    ISSN: 0935-6304
    Keywords: Capillary supercritical fluid chromatography ; Injection system ; Polycyclic aromatic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A sample introduction system for capillary supercritical fluid chromatography, which allows the dissolution of the sample in the supercritical mobile phase before being introduced into the column, was constructed and evaluated. Supercritical n-pentane was shown to solvate high-molecular-weight polycyclic aromatic compounds that could not be solvated using typical liquid solvents. In addition, split injection of a supercritical fluid solution was found to be more reproducible than split injections of a liquid solution. The potential of such an injection system was demonstrated, although further developments are needed in order to make the technique of practically utility.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986) 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0935-6304
    Keywords: Fast high-performance liquid chromatography ; Plasma and urine analysis ; Solid-phase extraction ; β-Glucuronide conjugation ; Anti-brain-edema agent ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A simple and rapid high-performance liquid chromatographic method for the determination of R[(5,6-Dichloro-2,3,9,9a-tetrahydro-3-oxo-9a-propyl-1-H-fluoren-7-yl)oxy]acetic acid (I) in human plasma and urine is described. The method utilizes Bond-Elut® cartridge facilitate the drug extraction. Analysis is performed on a short reversed-phase column with a mobile phase consisting of acetonitrile and phosphate buffer and quantification is carried out by ultraviolet detection with a wave-length set at 340 nm. The method is linear and reproducible for both plasma and urine analyses (0.25-50) μg/mL) with the detection limit of 125 ng/mL of plasma and urine. Plasma and urine concentrations of / at selected time intervals following I.V. administration of single rising doses are presented.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...