ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your search history is empty.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (134)
  • stability  (134)
  • Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics  (109)
  • Electrical Engineering, Measurement and Control Technology  (25)
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biosensors and Bioelectronics 5 (1990), S. 1-12 
    ISSN: 0956-5663
    Keywords: blood glucose ; calorimetric ; catalase ; catheter ; enzyme ; glucose oxidase ; implantation ; stability ; thermoelectric ; thermopile
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Electrical Engineering, Measurement and Control Technology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biosensors and Bioelectronics 6 (1991), S. 87-91 
    ISSN: 0956-5663
    Keywords: biocompatibility ; in vivo ; packaging ; sensors ; stability
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Electrical Engineering, Measurement and Control Technology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biosensors and Bioelectronics 7 (1992), S. 165-185 
    ISSN: 0956-5663
    Keywords: FAD ; biosensor ; discovery ; electrochemical mediators ; enzyme electrode ; glucose oxidase ; glucose sensor ; inhibitors ; physical properties ; reaction mechanism ; sources ; stability ; structure ; substrates
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Electrical Engineering, Measurement and Control Technology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Circuits, systems and signal processing 19 (2000), S. 423-435 
    ISSN: 1531-5878
    Keywords: Time-varying autoregressive models ; stability ; smoothness priors ; Tihkonov regularization ; constrained optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: Abstract The stability of time-varying autoregressive (AR) models is an important issue in such applications as time-varying spectrum estimation and electroencephalography simulation and estimation. In some cases, such as time-varying spectrum estimation, the models that exhibit roots near unit moduli are difficult to use. Thus a tighter stability condition such as stability with a positive margin is needed. A time-varying AR model is stable with a positive margin if the moduli of the roots of the time-varying characteristic polynomial are somewhat less than unity for every time instant. Recently, a new method for the estimation of the time-varying AR models was introduced. This method is based on the interpretation of the underdetermined time-varying prediction equations as an ill-posed inverse problem that is solved by Tikhonov regularization. The method is referred to as the deterministic regression smoothness priors (DRSP) scheme. In this paper, a stabilization method in which the DRSP scheme is augmented with nonlinear stability constrainst is proposed. The problem is formulated so that stability with a positive margin can also be achieved. The problem is solved iteratively with an exterior point algorithm. The performance of the algorithm is studied with a simulation. It is shown that the proposed approach is well suited to stable modeling of signals containing narrowband transitions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Circuits, systems and signal processing 19 (2000), S. 13-25 
    ISSN: 1531-5878
    Keywords: Singular systems ; delay ; consistency condition ; stability ; instability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: Abstract In this paper, the general class of singular systems with delay and linear constant coefficient singular systems with delay are discussed. First, several definitions of stability are presented for singular systems with delay, and general sufficient stability conditions and instability conditions are obtained. Second, stability and instability are analyzed for linear constant coefficient singular systems with delay.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1435-1536
    Keywords: Emulsions ; stability ; interfacial properties of emulsions ; soybean protein ; glycerides ; stabilised O/W emulsions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract The influence of chemically modified 7S fraction of soybean protein (7MSPF), and its partial replacement by mono- and di-glycerides in various ratios, on the rate of drop coalescence in concentrated corn oil-in-water emulsions has been investigated. A total emulsifier concentration of 2.0 % (wt/wt) was used. The minimum drop coalescence rate was achieved when using 1.0% (wt/wt) 7MSPF in conjunction with 0.5% (wt/wt) monoglyceride and 0.5 % (wt/wt) di-glyceride at pH 5.5. At other mono-/di-glycerides and protein/glycerides ratios, and at other pHs, the rate of drop coalescence was higher than when 2.0% (wt/wt) 7MSPF was used. The reduction in drop coalescence rate under these conditions is attributed to association of 7MSPF with the glycerides at the oil-water interface. The influence of protein/glycerides ratio on the viscoelastic properties of mixed interfacial films supports this view.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Journal of intelligent manufacturing 4 (1993), S. 183-198 
    ISSN: 1572-8145
    Keywords: Assembly planning ; subassembly ; liaison graph ; geometric reasoning ; assembly cost ; stability ; partial-order graph
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: The distribution of assembly workstations enables assembly operations to be done in parallel, while the multiple routing of parts in flexible assembly systems allows the opportunistic scheduling of assembly operations. This paper presents an assembly planning system, called the Assembly Coplanner, which automatically constructs an assembly partial order and generates a set of assembly instructions from a liaison graph representation of an assembly based on the extraction of preferred subassemblies. Assembly planning in Coplanner is carried out by the co-operation of multiple planning agents, such as the geometric reasoner, the physical reasoner, the resource manager and the plan coordinator, under the constraints of finding a cost-effective assembly plan in a flexible assembly system. The Coplanner identifies spatial parallelism in assembly as a means of constructing temporal parallelism among assembly operations. This is achieved in the following way: (1) the selection of a set of tentative subassemblies by decomposing a liaison graph into a set of subgraphs based on feasibility and difficulty of disassembly; (2) the evaluation of each of the tentative subassemblies in terms of assembly cost represented by subassembly selection indices; and (3) the construction of a hierarchical partial order graph (HPOG) as an assembly plan. A case study applying the Coplanner to a mechanical assembly is illustrated in this paper.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1572-8900
    Keywords: Chemiluminescence ; oxidation ; stability ; acrylonitrile-butadiene-styrene (ABS) ; ABS/polycarbonate blend
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract The thermal oxidative stability of various ABS/PC compounds was studied by means of the chemiluminescence technique. Similarly to pure ABS, Irganox 1076 and Irganox MD 1024 perform as moderate antioxidants in ABS/PC and (ABS/PC + lubricant) blends. Neither Tinuvin 144, Irgaphos 168, nor their mixture affects the durability of the ABS/PC blend. At the same time, (Irgaphos 168 + Tinuvin 144) in combination with Irganoxes was found to provide a noticeable enhancement in durability to the (ABS/PC + lubricant) system. Titanium dioxide pigments by themselves have only a slight influence on the oxidative stability of the ABS/PC blend. Durability of the (ABS/PC + pigment) and (ABS/PC + lubricant) systems was found to be the same and the overall protective effect of Irganox 1076 was similar in both the (ABS/PC + lubricant) and the (ABS/PC + lubricant + pigment) systems. Certain modifiers significantly improve the durability of the ABS/PC compounds, although their function may differ in the systems with and without pigments.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1572-8900
    Keywords: Chemiluminescence ; oxidation ; stability ; acrylonitrile-butadiene-styrene (ABS)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract The influence of lubricants, UV stabilizers, antioxidants, and metal deactivators on the resistance of ABS to thermal oxidation was studied by means of the chemiluminescence technique. Neither of the additives seems to affect significantly the induction period of oxidation. At the same time, the influence of various additives on the oxidation rate constant is remarkably different: the introduction of lubricants and UV stabilizers increases its value, while antioxidants and metal deactivators have the opposite effect. For the particular systems studied durability is decreased in samples containing the lubricant and UV stabilizers and increased in samples stabilized with the antioxidant and metal deactivator.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1572-8900
    Keywords: Capillary zone electrophoresis ; oligomers ; lactic acid ; glycolic acid ; 3-hydroxybutyric acid ; water solubility ; stability ; degradation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract In an attempt to increase the range of analytical techniques able to monitor ultimate degradation stages of degradable, biodegradable, and bioresorbable polymers, capillary zone electrophoresis (CZE) was used to analyze tentatively oligomers formed during thermal condensation of lactic, glycolic, anddl-3-hydroxybutyric acids. The influence of the buffer and of capillary coating are discussed in terms of electroosmotic flow. Typical analyses were first performed using a 0.1M borate buffer (pH 8.9) with anodic injection. In the case of lactic acid, seven peaks were well separated, while only three peaks were observed for glycolic acid. A more complex situation was found fordl-3-hydroxybutyric acid oligomers. The first five peaks were split. The major component of each doublet was attributed to hydroxy-terminated oligomers, whereas the satellite peaks were assigned to oligomers bearing a C=C double bond at the noncarboxylic terminus. CZE of pH-sensitive lactic acid oligomers was also performed in 0.05M phosphate buffer (pH 6.8) with cathodic injection after physical coating of the fused-silica capillary with DEAE-Dextran. The buffer-soluble fraction present in lactic acid oligomers was extracted from a dichloromethane solution. Extracts issued from different batches of lactic acid condensates gave a constant water-solubility pattern whose cutoff was at the level of the decamer. CZE was also used to monitor thein vitro aging of aqueous solutions of these water-soluble oligomers. The lactyllactic acid dimer appeared more stable than higher oligomers, thus showing that ultimate stages of the degradation did not proceed at random. These physicochemical characteristics were used to complement the degradation pathway based on diffusion of oligomers duringin vitro aging of large size lactic acid plates made by compression molding. CZE data showed that lactic acid was the only component which was released in the aqueous medium during degradation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...