ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    ISSN: 1618-2650
    Keywords: Best. von Metallen in Biolog. Geweben ; Spektralphotometrie, Atomabsorption ; Extraktionsverfahren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1618-2650
    Keywords: Best. von Spurenelementen, Schwermetallen in Wasser ; Spektralphotometrie, Atomabsorption ; Bodensee
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Monatliche AAS-Messungen im Jahre 1977 auf die Elemente As, Pb, Cd, Cr, Hg, Se, Zn, Fe, Mn, Ni, Co, Al und B im Rohwasser und im Trinkwasser des Zweckverbandes Bodenseewasserversorgung sowie an ausgewählten Tiefenprofilen im Überlinger See werden diskutiert. Die angewandten Untersuchungsmethoden werden eingehend erläutert. Die Ergebnisse zeigen, daß der Gehalt der toxischen Metalle im Bodenseewasser unter 1% der laut Trinkwasserverordnung zulässigen Grenzkonzentrationen liegt. Die höchsten Konzentrationen mit maximal 7% des Grenzwertes wurden beim Element Arsen gefunden — eine für die Bodenseetrinkwasserwerke jedoch immer noch beruhigende Zahl. Dennoch soll speziell diesem Element in weitergehenden Untersuchungen erhöhte Aufmerksamkeit gewidmet werden.
    Notes: Summary A survey is given based on monthly measurements over a one-year period (1977) to determine the trace metals in the raw and drinking water and in two vertical profiles of the Lake of Constance (Überlinger See) by means of atomic absorption spectrometry. The methods used are discussed in detail. The results showed that the content of the toxic metals Hg, Se, Pb, Cr and Cd amounts to less than 1% of the concentration limits due to German law. The highest concentrations were found for the element As, which reached about 7% of the limiting concentration. Further investigations are therefore concerned with this element.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1618-2650
    Keywords: Best. von Chrom ; Spektralphotometrie, Atomabsorption ; Arbeitsbedingungen, Einflüsse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wurde die Vielfältigkeit der Einflüsse von Mineralsäuren, Lösungsgenossen, Brennererwärmung und der Wertigkeit des Ions, welche insgesamt die Bestimmung von Chrom mittels AAS sehr problematisch gestalten, systematisch untersucht. Durch Verwendung einer brenngasarmen Acetylen-Lachgasflamme werden diese Schwierigkeiten weitestgehend beseitigt, was an hochprozentigen Normstählen demonstriert wird.
    Notes: Summary The variety of influences, such as mineral acids, heating of the burner head, solvent components and valency of the ion, was examined systematically. By use of a lean acetylene-nitrous oxide flame these difficulties can by eleminated extensively, and this is demonstrated on high chromium standard steels.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1618-2650
    Keywords: Best. von Silber, Cadmium, Blei, Zink in Wasser ; Spektralphotometrie, Atomabsorption ; flammenlos, Ta-Streifen ; Best. von Zink neben Albumin in Serum ; Spektralphotometrie, Atomabsorption ; flammenlos, Ta-Streifen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A simple and efficient tantalum strip atomizer is described suitable for use in the atomic absorption determination of trace elements in water. The cell operates with an inexpensive Powerstat-transformer unit to provide the necessary electrothermal heat for atomization. It can be easily fitted in the place of the burner in atomic absorption instruments. The atomizer has been used to determine Ag, Cd, Pb, and Zn in tap water samples and Zn in the presence of albumin.
    Notes: Zusammenfassung Die elektrische Erhitzung des Tantalstreifens wird mit Hilfe einer preisgünstigen Energiequelle (Powerstat/Transformator) vorgenommen, die leicht anstelle des Brenners in den üblichen Geräten untergebracht werden kann. Das Verfahren wurde zur Bestimmung von Ag, Cd, Pb und Zn in Leitungswasser sowie von Zink neben Albumin angewendet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1618-2650
    Keywords: Best. von Metallen in Biolog. Material ; Spektralphotometrie, Atomabsorption ; Spurenanalyse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein Erfahrungsbericht über die Atomabsorptionsspektroskopie mit und ohne Flamme gegeben, wobei die Schwerpunkte in der Erkennung und Beseitigung von Störungen liegen. Anhand von Beispielen werden für die Flammen-AAS einschließlich Probenboot-Technik Störungen diskutiert, die durch Atombindungszustand, Untergrundabsorption, Viscositäts- und Oberflächenspannungsänderung bedingt sind. Für die flammenlose Quecksilber-Analytik wird ein selbstgebauter Zusatz mit Untergrundkompensator und für die flammenlose Hochtemperaturmethode ein selbstgebauter Tantalofen vorgestellt. Ausführlich wird auf Störungen durch Absorptionsüberlagerungen, sowie auf Optimierungen in der Direktanalyse von Urin und Blut bzw. Serum auf Schwermetallspuren beim Arbeiten mit kommerziellen Graphitöfen eingegangen.
    Notes: Abstract The basis of this experience report about atomic absorption spectroscopy with and without flame is the recognition and elimination of interferences. Interferences which are caused by the bonding state of the atoms, background absorption, viscosity and surface tension changes, are discussed with the aid of examples for flame AAS including sample boat technique. A laboratory-made device with background compensator for the flameless mercury analysis, and a laboratory-made tantalum furnace for the flameless high temperature method are presented. The interferences by absorption superimpositions and optimisations in the direct analysis of heavy trace metals in urine, blood or serum are discussed in detail for commercial graphite furnaces.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    ISSN: 1618-2650
    Keywords: Best. von Cadmium in Geschirr ; Spektralphotometrie, Atomabsorption ; Cd-Abgabe von Dekoren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Buntes Porzellangeschirr wurde auf Abgabe von Cadmium an die Testflüssigkeit 4% ige Essigsäure überprüft, die 24 h lang bei Raumtemperatur mit den Dekoren in Berührung stand. Die Cadmiumbestimmung erfolgte mittels Atomabsorptionsspektralphotometrie. Etwa ein Viertel der untersuchten Proben lag über der in den USA zulässigen Höchstabgabe von 0,5 ppm Cadmium. Die Gesamtabgabe der Geschirrstücke überschritt häufig die von der WHO/FAO noch als duldbar angesehene perorale Aufnahme von 400 bis 500 μg Cadmium pro Mensch und Woche und erreichte Mengen bis zu einem Drittel der als tödlich geltenden Dosis. Saure Lebensmittel lösen bei identischen Versuchsbedingungen größenordnungsmäßig gleiche Cadmiummengen wie 4% ige Essigsäure heraus. Bei wiederholten Extraktionen mit jeweils erneuerter Testflüssigkeit bleiben selbst nach acht Extraktionen noch Restgehalte bestehen, die über dem Grenzwert der USA liegen. Die baldige Festlegung eines Grenzwertes auch in der BRD wird als dringend angesehen, um das gesundheitliche Risiko durch mit Cadmium kontaminierte Lebensmittel auszuschließen.
    Notes: Abstract The extraction of cadmium from coloured porcelain crockery was tested with a solution of 4% acetic acid, which was in contact with the decoration over a period of 24 h at room temperature. The level of cadmium was determined by means of atomic absorption spectrophotometry. Roughly one quarter of the specimens contained more than 0.5 ppm cadmium-the maximum permissible figure in U.S.A. Frequently, the total weight of cadmium extracted from the pieces of crockery also exceeded the peroral cadmium intake of 400–500 μg/week, which is considered to be tolerable by the WHO/FAO for human individuals; in fact, one third of the dose which is generally thought to be deadly was even reached in some cases. Under identical test conditions, foodstuffs containing acids produce quantities of cadmium of the same dimension as 4% acetic acid. When cadmium was repeatedly extracted from a test object using a fresh test solution each time, traces above the U.S.A. limit were even found after eight extractions. The fixing of a limit in the Federal Republic of Germany as well is considered to be a matter of utmost urgency, if food contaminated with cadmium is not to be a risk to health.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1618-2650
    Keywords: Best. von Nickel und Kobalt in Meteoriten ; Spektralphotometrie, Atomabsorption
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    ISSN: 1618-2650
    Keywords: Best. von Blei in Lebensmitteln ; Spektralphotometrie, Atomabsorption ; Trockenveraschung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird auf Fehlermöglichkeiten bei der Bleibestimmung hingewiesen und eine Methode beschrieben, mit der diese Fehler weitgehend vermieden werden können. Bei der angewendeten Trockenveraschung wird die Flüchtigkeit von Blei in Abhängigkeit von der mit Thermoelementen gemessenen Temperatur im Veraschungsgut ermittelt. Veraschungsdaten für ein Lebensmittel, z.B. Gemüse, dürfen nicht einfach auf anders zusammengesetzte Lebensmittel (z. B. Fleisch) übertragen, sondern müssen experimentell ermittelt werden. Bei der Bleibestimmung in Lösungen von Lebensmittelaschen mit Hilfe der Atomabsorptionsspektrometrie stören viele Matrixelemente. Durch eine Sulfidfällung mit Silberionen als Mitfällungspartner wird diese Störung umgangen und gleichzeitig das Blei angereichert; durch eine vorherige Nitrat-Carbonat-Schmelze der Aschen werden die vorhandenen Kohlenstoffreste beseitigt und in Säure schwerlösliche Verbindungen aufgeschlossen. Die Verwendung von Flußsäure zur Zerstörung von Silicaten, die nur Nachteile bringt, kann dadurch entfallen. Die Bleibestimmung in der erhaltenen Meßlösung im Atomabsorptionsspektrometer wird durch Vergleich mit entsprechenden Eichlösungen vorgenommen.
    Notes: Abstract Some possible errors are pointed out, which can occur in the determination of lead and a method is described which minimizes these errors. The loss of lead during the dry-ashing-procedure was determined in dependence on the temperature in the sample measured by immersed thermocouples. It is not advisable to transfer ashing data from one foodstuff (e.g. vegetable) to foodstuffs of different composition (e.g. meat); such data must be determined experimentally. Many matrix elements in ash solutions influence the lead determination by atomic absorption spectroscopy. By H2S coprecipitation of lead and added silver ions as PbS/Ag2S this disturbance can be avoided and the lead concentration is simultaneously increased. With the aid of a nitrate-carbonate melt before the H2S coprecipitation the residual carbon of the ash is removed and acid-insoluble compounds are made accessible. The use of hydrofluoric acid for destroying the silicates, which is disadvantageous, can thus be omitted. The lead content in the final solution is determined in an atomic absorption spectrometer by comparison with a standard solution of appropriate concentration.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1618-2650
    Keywords: Best. von Magnesium ; Spektralphotometrie, Atomabsorption ; Untersuchung von Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Optimum conditions and the influence of 54 ions on the determination of magnesium by atomic absorption spectrophotometry have been investigated. The use of the nitrous oxide-acetylene flame will remove any interference effects. In the air-acetylene flame the standard additions technique was studied and proved to be suitable except when silicate was present. Completely satisfactory determinations were obtained when the standard additions technique was applied to solutions containing an alkaline earth metal as a releasing agent.
    Notes: Zusammenfassung Die optimalen Bedingungen sowie der Einfluß von 54 Ionen wurden untersucht. Durch Verwendung der N2O-Acetylen-Flamme werden alle Störungen vermieden. In der Luft-Acetylen-Flamme erwies sich die Methode der Standardzugaben als geeignet, außer bei Gegenwart von Silicat. Alle Störungen können auch in dieser Flamme unterbunden werden, wenn die Methode der Standardzugaben zusammen mit einem Zusatz eines anderen Erdalkalimetalls angewendet wird.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1618-2650
    Keywords: Best. von Magnesium ; Spektralphotometrie, Atomabsorption ; Einfluß von Si, Al, Be, Zr, Ti Verw. von Sulfosalicylsäure, Acetylen-Luft-Flamme
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Non-sufficient attention seems to have been paid to the influence of various ions on the atomic absorption spectrophotometric determination of magnesium. SiO3 2+, Al3+, Be2+, Zr(IV), Ti(IV) decrease remarkably the Mg absorbance in air-acetylene flames, but the most interesting positive or negative effects on the absorbance of magnesium are exhibited in ternary systems of ions. 5-Sulphosalicylic acid protects magnesium in the presence of the above mentioned elements in binary or ternary ion systems and makes the atomic absorption spectrophotometric determination of magnesium possible in the presence of these ions.
    Notes: Zusammenfassung Den verschiedenen Beeinflussungen durch Kationen und Anionen bei der atomabsorptionsspektrophotometrischen Bestimmung von Magnesium wurde bisher nur unzureichende Aufmerksamkeit gewidmet. Vor allem SiO3 2−, Al3+, Be2+, Zr(IV), Ti(IV) üben einen merklichen negativen Einfluß auf die Absorption von Magnesium in der Acetylen-Luft-Flamme aus. Von besonderer Bedeutung sind verstärkte negative bzw. positive Einflüsse in ternären Ionensystemen, die die Resultate stark beeinträchtigen können. 5-Sulfosalicylsäure eignet sich im allgemeinen gut zur Aufhebung des störenden Ioneneinflusses bei der Bestimmung von Magnesium neben den oben genannten Elementen in binären oder ternären Systemen in Acetylen-Luft-Flammen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...