ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    ISSN: 1618-2650
    Keywords: Best. von Metallen in Biolog. Geweben ; Spektralphotometrie, Atomabsorption ; Extraktionsverfahren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1618-2650
    Keywords: Best. von Spurenelementen, Schwermetallen in Wasser ; Spektralphotometrie, Atomabsorption ; Bodensee
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Monatliche AAS-Messungen im Jahre 1977 auf die Elemente As, Pb, Cd, Cr, Hg, Se, Zn, Fe, Mn, Ni, Co, Al und B im Rohwasser und im Trinkwasser des Zweckverbandes Bodenseewasserversorgung sowie an ausgewählten Tiefenprofilen im Überlinger See werden diskutiert. Die angewandten Untersuchungsmethoden werden eingehend erläutert. Die Ergebnisse zeigen, daß der Gehalt der toxischen Metalle im Bodenseewasser unter 1% der laut Trinkwasserverordnung zulässigen Grenzkonzentrationen liegt. Die höchsten Konzentrationen mit maximal 7% des Grenzwertes wurden beim Element Arsen gefunden — eine für die Bodenseetrinkwasserwerke jedoch immer noch beruhigende Zahl. Dennoch soll speziell diesem Element in weitergehenden Untersuchungen erhöhte Aufmerksamkeit gewidmet werden.
    Notes: Summary A survey is given based on monthly measurements over a one-year period (1977) to determine the trace metals in the raw and drinking water and in two vertical profiles of the Lake of Constance (Überlinger See) by means of atomic absorption spectrometry. The methods used are discussed in detail. The results showed that the content of the toxic metals Hg, Se, Pb, Cr and Cd amounts to less than 1% of the concentration limits due to German law. The highest concentrations were found for the element As, which reached about 7% of the limiting concentration. Further investigations are therefore concerned with this element.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1618-2650
    Keywords: Best. von Chrom ; Spektralphotometrie, Atomabsorption ; Arbeitsbedingungen, Einflüsse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wurde die Vielfältigkeit der Einflüsse von Mineralsäuren, Lösungsgenossen, Brennererwärmung und der Wertigkeit des Ions, welche insgesamt die Bestimmung von Chrom mittels AAS sehr problematisch gestalten, systematisch untersucht. Durch Verwendung einer brenngasarmen Acetylen-Lachgasflamme werden diese Schwierigkeiten weitestgehend beseitigt, was an hochprozentigen Normstählen demonstriert wird.
    Notes: Summary The variety of influences, such as mineral acids, heating of the burner head, solvent components and valency of the ion, was examined systematically. By use of a lean acetylene-nitrous oxide flame these difficulties can by eleminated extensively, and this is demonstrated on high chromium standard steels.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1618-2650
    Keywords: Best. von Silber, Cadmium, Blei, Zink in Wasser ; Spektralphotometrie, Atomabsorption ; flammenlos, Ta-Streifen ; Best. von Zink neben Albumin in Serum ; Spektralphotometrie, Atomabsorption ; flammenlos, Ta-Streifen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A simple and efficient tantalum strip atomizer is described suitable for use in the atomic absorption determination of trace elements in water. The cell operates with an inexpensive Powerstat-transformer unit to provide the necessary electrothermal heat for atomization. It can be easily fitted in the place of the burner in atomic absorption instruments. The atomizer has been used to determine Ag, Cd, Pb, and Zn in tap water samples and Zn in the presence of albumin.
    Notes: Zusammenfassung Die elektrische Erhitzung des Tantalstreifens wird mit Hilfe einer preisgünstigen Energiequelle (Powerstat/Transformator) vorgenommen, die leicht anstelle des Brenners in den üblichen Geräten untergebracht werden kann. Das Verfahren wurde zur Bestimmung von Ag, Cd, Pb und Zn in Leitungswasser sowie von Zink neben Albumin angewendet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1618-2650
    Keywords: Best. von Wismut in Stahl ; Spektralphotometrie, Atomabsorption ; flammenlos
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A method for the determination of bismuth in high and low alloy steels has been developed. Samples were dissolved in hydrochloric-nitric acid (2∶1). A graphite furnace of Massmann-type was used for determinations. Ammonia was added to the samples in the tube. Because of this treatment samples could be ashed at higher temperatures and non-specific absorption was thereby minimised. Samples could be determined without background correction. The time for one analysis was 15 min. Interferences from chromium, nickel, iron and molybdenum as well as from the acids used for dissolution of samples were investigated. It was shown that the inert gas flow-rate during ashing affected the sensitivity.
    Notes: Zusammenfassung 0,5 g der Probe wird in einem Salzsäure/Salpetersäure-Gemisch (2∶1) gelöst und auf 50 ml verdünnt. 2 μl dieser Lösung werden in einen Graphitofen nach Massmann überführt und mit 10 μl 0,4 M Ammoniak versetzt. Dadurch konnte die Probe bei höherer Temperatur verascht werden, wodurch die unspezifische Absorption so vermindert wurde, daß ohne Untergrundskorrektur gearbeitet werden konnte. Eine vollständige Analyse dauert 15 min, die Nachweisgrenze beträgt 0,5 μg Bi/g Probe. Störungen sowohl durch Chrom, Nickel, Eisen und Molybdän als auch durch Salzsäure und Salpetersäure wurden untersucht. Die Strömungsgeschwindigkeit des inerten Spülgases beeinflußt die Signalhöhe.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1618-2650
    Keywords: Best. von Blei, Cadmium in Wein ; Spektralphotometrie, Atomabsorption ; Extraktionsmethode
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The insolubility of sugars and fruit acids in MIBK allows the direct extraction of heavy metals by APDC from wine and similar products. With special precautions an accuracy of /+-5% can be obtained for Pb and Cd in the concentration range from 0.1–1 ppm and 1–10 ppb, respectively. Together with our experiences a brief survey of the most recent literature is also presented.
    Notes: Zusammenfassung Die Unlöslichkeit der Zucker und Fruchtsäuren in MIBK erlaubt die Direktextraktion von Schwermetallionen mittels APDC aus Wein und ähnlichen Produkten. Unter Beachtung besonderer Vorsichtsmaßnahmen wird für Pb im Bereich von 0,1–1 ppm und für Cd im Bereich 1–10 ppb eine Genauigkeit von ± 5% erhalten. Gleichzeitig wird zusammen mit unseren Erfahrungen ein kurzer Überblick über die neueste Literatur gegeben.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1618-2650
    Keywords: Best. von Arsen in Wasser ; Spektralphotometrie, Atomabsorption ; flammenlos, Müllsickerwasser
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; Optimierung von Meßbedingungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Eingehende Untersuchungen zeigen, daß die Leistungsfähigkeit der Atomabsorptionsspektroskopie gewöhnlich nicht optimal genutzt wird. Der Einfluß wesentlicher Größen, wie Viscosität, Temperatur, Salzkonzentrationen, Oberflächenspannung usw. wird untersucht bzw. anhand der Hagen-Poiseuilleschen Gleichung diskutiert.
    Notes: Abstract Detailed tests have been made to show the efficiency of a modern atomic absorption spectrometer. The influence of different parameters as: viscosity, temperature, concentration of salts, surface tension etc., is discussed on the basis of Hagen-Poiseuille's equation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; ohne Wägung, auf See
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Um das auf See problematische Einwiegen von Erzproben zur Analyse durch Atomabsorptions-Spektrometrie zu umgehen, wird eine indirekte Ermittlung der eingesetzten Probemenge durch die Bestimmung eines „Leitelementes“ mittels Isotopfluorescenzanalyse erprobt. Am Beispiel von Manganknollen des Pazifischen Ozeans, die 15–30% Mn, 0,5–1,5% Ni und Cu enthalten, wird gezeigt, daß sich die beiden zuletzt genannten Elemente auf diese Weise mit einer Genauigkeit von besser als 10% rel. bestimmen lassen.
    Notes: Abstract The weighing of ore samples to be analyzed by atomic absorption spectrometry is somewhat problematical at sea. To evade the weighing, tests have been made to try out an indirect determination of the mass of the sample by determining a “reference element” by means of isotope fluorescence analysis. The analysis of manganese nodules from the Pacific Ocean, containing 15–30% of Mn and 0.5–1.5% of Ni and Cu, is quoted as an illustration. It has been shown that the two latter elements can be determined in this way with an accuracy of at least 10% rel.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1618-2650
    Keywords: Analyse von Kupfer, Kupfersalzen ; Spektralphotometrie, Atomabsorption ; Ausfällen der Matrix als CuS
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur Bestimmung der Elementspuren Cd, Co, Fe, In, Mn, Ni, Pb, Tl und Zn in reinem Kupfer und Kupfersalzen wird die Matrix als CuS mit Thioacetamid als Fällungsreagens ausgefällt. In 3 N salzsaurer Lösung werden die Elemente mit Ausbeuten ≥ 90 %, Tl zu 75 %, im Filtrat wiedergefunden. Nach Zusatz von HNO3 und Einengen des Filtrats, erhält man ein praktisch rückstandsfreies Spurenkonzentrat, in dem die angereicherten Elemente durch Flammen-Atomabsorptions-Spektrometrie bestimmt werden. Die relative Standardabweichung s/¯x liegt im allgemeinen bei Werten um 0,03. Für Einwaagen von 1 g Kupfer werden Nachweisgrenzen erzielt, die, je nach Element, zwischen 0,2 und 3 ppm liegen.
    Notes: Abstract For the determination of traces of elements such as Cd, Co, Fe, In, Mn, Ni, Pb, Tl and Zn in pure copper and copper salts the matrix is precipitated as CuS using thioacetamide as precipitating reagent. In solutions containing 3 N hydrochloric acid, the recovery of the elements is ≥90 % (Tl 75%). By addition of HNO3 and evaporation of the filtrate to dryness a trace concentrate is received which is practically free of a salt residue and in which the preconcentrated elements are determined by flame AAS. The relative standard deviation s/¯x is generally about 0.03. Using samples of 1 g of copper the limit of detection for different elements was found to be between 0.2 and 3 ppm.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...