ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1618-2650
    Keywords: Röntgenfluorescenz-Spektrometrie ; Matrixkorrektur, Untergrundkorrektur, Analyse von Edelmetallen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new evaluation method has been developed allowing the consideration of all elements, which are absorbing at longer wavelengths, by only one correction factor. The determination of the background is based on the experimentally stated correlation between the scattered intensities of different wavelengths.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1618-2650
    Keywords: Best. von Zink, Zirkonium, Uran in Thoriumoxid ; Röntgenfluorescenz-Spektrometrie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An X-ray fluorescence method for the direct determination of Zn, Zr and U in thoria at trace levels has been developed. Thoria samples are mixed with boric acid binder and double-layer pellets are prepared. Instrumental parameters are selected to minimise interferences and to get optimum peak/background ratio. The detection limits for Zn, Zr and U are 10, 100 and 50 ppm with average precision of 8, 16 and 14%, respectively.
    Notes: Zusammenfassung Ein direktes Verfahren zur Bestimmung von Zn-, Zr- und U-Spuren in Thoriumoxid wird empfohlen. Die Probe wird hierbei zusammen mit Borsäure als Bindemittel zu einer Doppelschicht-Tablette gepreßt. Geeignete instrumentelle Parameter gewährleisten ein Minimum an Störungen und ein optimales Peak/Hintergrund-Verhältnis. Die Nachweisgrenzen für Zn, Zr und U betragen 10, 100 bzw. 50 ppm, die durchschnittliche Genauigkeit 8, 16 bzw. 14%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1618-2650
    Keywords: Röntgenfluorescenz-Spektrometrie ; Statist. Kenngrössen der Additionsmethode
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Genauigkeit und Empfindlichkeit eines Meßverfahrens werden charakterisiert durch den mittleren Fehler und die Unterscheidungs- und Nachweisgrenze. Diese Kenngrößen werden für die Additionsmethode in der Röntgen-Fluorescenzanalyse behandelt, soweit sie von der Impulszählstatistik abhängen. Einflüsse, die von der Probenvorbereitung herrühren und nichtstatistischer Art sind, bleiben außer Betracht. In den Kreis der Betrachtungen, der die Fälle der linearen und nichtlinearen Eichkurve umfaßt, werden auch die Irrtumswahrscheinlichkeit 2. Art und der Einfluß der Meßsystemtotzeit einbezogen.
    Notes: Abstract The accuracy and sensitivity of a measuring method are characterised by the limits of distinction and indication. These criteria are treated for the addition method in X-ray fluorescence analysis so far as they depend on the statistics of pulse counting. The influences of the sample preparation are not taken into consideration because of their non-stastistical nature. The paper covers the cases of linear and non-linear calibration curve with respect to the error probability of second type and the influence of the dead-time of the measuring equipment.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1618-2650
    Keywords: Best. der Stöchiometrie von Halbleitern ; Röntgenfluorescenz-Spektrometrie ; Cd-Hg-Se, Cd-Hg-Te
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Semiconductors of the composition Cd v Hg1−v Se and Cd x Hg1−x Te are gaining growing industrial interest. The energy gap between the bands of such systems depends significantly on the magnitude of the mole fractions v and x. X-ray fluorescence analysis of acid solutions of these crystals is a simple and precise procedure to determine the stoichiometry. Sample preparation, calibration series and results are discussed.
    Notes: Zusammenfassung Halbleiter der Typen Cd v Hg1−v Se und Cd x Hg1−x Te gewinnen zunehmend industrielles Interesse. Der Energieabstand der Bänder in solchen Systemen hängt entscheidend von der Größe der Molenbrüche v und x ab. Ein einfaches und sicheres Analysenverfahren zur Ermittlung der Stöchiometrie ist die Röntgenfluorescenzanalyse von sauren Lösungen dieser Kristalle. Die Probenvorbereitung, Eichreihen und Resultate werden diskutiert.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1618-2650
    Keywords: Best. von Eisen, Barium, Strontium in Ferriten ; Röntgenfluorescenz-Spektrometrie ; Aufschluß mit Kaliumdisulfat, innerer Standard
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Eine Methode zur röntgenfluorescenzanalytischen Bestimmung der Hauptelemente in Ba- und Sr-Ferriten wird angegeben. Das Probenmaterial wird nach Zufügen einer konstanten Menge eines inneren Standardelements mit Kaliumdisulfat aufgeschlossen, unter Zusatz von Carnauba-Wachs gemahlen und zu einem lagerfähigen Preßling verdichtet.
    Notes: Abstract A method for rapid quantitative analyses of the main components in Ba- and Sr-ferrites by X-ray fluorescence has been developed. The sample is fused after addition of a constant quantity of an internal standard in K2S2O7, ground in a mortar mill with the addition of Carnauba wax and then compacted into a disk using a hydraulic press.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1618-2650
    Keywords: Best. von Kalium in Wasser ; Röntgenfluorescenz-Spektrometrie ; Tetraphenylborat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein Verfahren für die quantitative Bestimmung von Kalium mit Hilfe der energiedispersiven Röntgenfluorescenzanalyse beschrieben, das für die Anwendung auf Wasserproben ausgearbeitet wurde. Das Kalium wird als Tetraphenylborat gefällt und gemessen. Zur Anregung der Fluorescenzstrahlung dient eine Röntgenröhre mit Wolframanode und Titan als Sekundärtarget, zur Messung der Röntgenspektren wird ein Si(Li)-Detektor verwendet. Unter den beschriebenen Versuchsbedingungen können 0,1–1000 μg (0,04–400 μg/cm2) Kalium bestimmt werden.
    Notes: Summary A procedure is described for the quantitative determination of potassium in water samples, using energy dispersive X-ray fluorescence analysis. Potassium is precipitated and measured as tetraphenyloborate. The fluorescence radiation is excited employing a tungsten X-ray tube and titanium as secondary target. A Si(Li)-detector is used for measuring the X-ray spectra. With the conditions described, 0.1–1000 μg (0.04–400 μg/cm2) of potassium can be determined.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    ISSN: 1618-2650
    Keywords: Röntgenfluorescenz-Spektrometrie ; Aktivierungsanalyse ; Radiochemische Analyse ; Überprüfung poissonverteilter Meßwerte
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Meßergebnisse der Analysentechnik, soweit sie auf Elementarereignissen beruhen, gehorchen der Poissonverteilung, die aus grundlegenden Prämissen abgeleitet wird. In der Praxis geht sie in eine singuläre Normalverteilung über. Durch die Kombination der Eigenschaften beider Verteilungen ist es möglich, einen Schnelltest auf statistische Reinheit einer Meßreihe aufzustellen, der Schlüsse auf Vorhandensein und Art von Störungen der Meßeinrichtung zuläßt. Die Kriterien zur Feststellung eines Ganges der Meß-werte und eines Ausreißers werden behandelt.
    Notes: Abstract The results of analytical measurements based on elementary events follow the poisson distribution which is derived from fundamental principles. In practice this distribution is converted into a singular normal distribution. By combining the properties of both distributions it is possible to state a quick examination of the statistical purity of a series of measurements with the aim to find out the existence and kind of troubles in measuring equipment. The criteria for determining a drift and an outlier in a series of measurements are treated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1618-2650
    Keywords: Best. von Neptunium neben Plutonium, Uran ; Röntgenfluorescenz-Spektrometrie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1618-2650
    Keywords: Röntgenfluorescenz-Spektrometrie ; Fixierung von Niederschlägen als Meßprobe
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1618-2650
    Keywords: Röntgenfluorescenz-Spektrometrie ; Kieselgelstandards für Spurenelemente
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Kieselgelstandards eignen sich für die Eichung der Bestimmung von Spurenelementen in pulverförmigen Proben durch Röntgenfluorescenzanalyse. Die Herstellung der Standards sowie die Untersuchungen auf Reproduzierbarkeit und Fehler werden beschrieben.
    Notes: Abstract Silica gel samples are suitable for calibration of trace element determination in powders by X-ray fluorescence. The preparation of the silica gel samples and the investigations related to reproducibility and errors are described.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...