ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1618-2650
    Keywords: Best. von Fluorid in Purex-Prozeßlösung ; Elektroden, ionenselektive
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Durch destillative Fluoridabtrennung und anschließende elektrometrische Bestimmung läßt sich der Fluoridgehalt wäßriger und organischer Purex-Prozeßlösungen mit guter Genauigkeit bestimmen. Der Meßbereich der Methode liegt zwischen 5 und 500 μg Fluorid/Aliquot, die Bestimmungsgrenze bei 5 · 10−5 Mol Fluorid/l (1 ppm). In den Lösungen vorhandene Fluorokomplexbildner (Al3+, Zr4+, La3+, UO2 2+) stören die Fluoridanalysen nicht.
    Notes: Abstract The fluoride content of aqueous and organic Purex process solutions can be determined with good reproducibility and accuracy. The method includes a distillation separation of fluoride and its subsequent electrometric determination using a fluoride-selective electrode. The analytical range covers 5 to 500 μg of fluoride per aliquot and the concentration limit is 5×10−5 M (1 ppm). Complexing cations like Al(III), Zr(IV), La(III), and U(VI) do not interfere.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1618-2650
    Keywords: Best. von Sulfat, Barium, Strontium ; Potentiometrische Titration ; Pb-sensitive Elektrode ; Elektroden, ionenselektive ; Bleisensitive Elektrode zur Best. von Sulfat, Ba, Sr.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die bleisensitive Elektrode der Fa. Orion spricht neben Bleiionen auch auf Sulfationen an. Dies ermöglicht die potentiometrische Titration von Sulfat mit Bariumperchlorat sowie die Titration von Barium und Strontium mit Natriumsulfat. Der günstigste pH-Bereich liegt zwischen 5 und 7. Titriermedium sind Dioxan-Wasser-Gemische. Die Verfahren sind sehr empfindlich und erlauben in allen Fällen die Titration bis herab zu 5·10−4 mMol. Anwendungsbeispiele für die Bestimmung von Schwefel in organischen Verbindungen nach Schöniger- oder Wickbold-Verbrennung sind angegeben.
    Notes: Abstract The Orion lead electrode was found to be responsive not only to lead ions but to sulphate ions, too. This offers possibilities to titrate sulphate with barium perchlorate and reversely barium and strontium with sodium sulphate. The useful pH range is 5–7. Dioxan-water mixtures serve as solvents. The described methods are highly sensitive and allow determinations down to 5×10−4 millimoles. Examples are given for the determination of sulphur in organic samples after combustion according to Schöniger or Wickbold.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1618-2650
    Keywords: Best. von Ammoniak, Nitrat, Stickstoffverbindungen in Wasser ; Elektroden, ionenselektive
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Two types of electrodes for the determination of ammonia are compared: one of the liquid membrane and one of the gas detecting type. Important electrode characteristics as response time, sensitivity and selectivity are commented. The ammonia electrode was tested in practice by analysis of ammonia and nitrate in canal water. The precision of the methods described was tested by analysis of synthetic samples, and by comparison with a volumetric and colorimetric method.
    Notes: Zusammenfassung Zwei Elektrodentypen (Flüssig-Membran und Gasdetektor) für die Ammoniakbestimmung wurden einem Vergleich unterzogen. Wichtige Charakteristiken (Ansprechzeit, Empfindlichkeit und Selektivität) werden diskutiert. Die praktische Prüfung erfolgte an Hand der Bestimmung von Ammoniak und Nitrat in Kanalwasser. Die Präzision wurde mit synthetischen Proben getestet sowie durch Vergleich mit einer volumetrischen und einer colorimetrischen Methode.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1618-2650
    Keywords: Best. der Aminogruppe ; Elektroden, ionenselektive ; Chloridelektrode
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1618-2650
    Keywords: Best. von Nitrat in Plutoniumoxid ; Elektroden, ionenselektive
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1618-2650
    Keywords: Best. von SelektivitÄtskonstanten ; Elektroden, ionenselektive ; Halogenidelektroden
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die SelektivitÄtskonstanten von Halogenidelektroden 2. Art, die durch elektrolytische Beschichtung von SilberstÄben einfach herzustellen sind, wurden nach verschiedenen Methoden bestimmt und mit den Werten der Orion Halogenidelektroden verglichen. Beide Elektrodentypen zeigen gut übereinstimmende Zahlen. Au\erdem sind die SelektivitÄtskonstanten unabhÄngig von der Bestimmungsmethode, wenn die Messungen im geeigneten Konzentrationsbereich vorgenommen werden. Ein Kriterium wird diskutiert, nach welchem erkannt werden kann, ob SelektivitÄtswerte echte Konstanten sind.
    Notes: Abstract The selectivity constants of halide electrodes of the second kind, prepared by electrolytical coating of silver rods, were determined and compared with the selectivity constants of the Orion solid state halide electrodes. The values of both electrode types are in good agreement. Three different determination methods were considered, where the results proved to be independent of the method, provided the appropriate concentration range is chosen for the measurements. A criterion for assessing whether or not selectivity values are real constants is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1618-2650
    Keywords: Elektroden, ionenselektive ; Nitrat-membranelektrode, statist. Erfassung der Stabilität
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary To estimate the time stability of a nitrate-selective liquid membrane electrode, the serial correlation method was used. From the values of the random variableR 1 (the coefficient for serial correlation) results that the statistical conclusion, namelyy=f(n), could not be identical with that one concerning the parameters of the transfer functiony=f(c).
    Notes: Zusammenfassung Die zeitliche Stabilität einer flüssigen Nitrat-Membranelektrode wird statistisch mit Hilfe der Methode der Serienkorrelation abgeschätzt. Aus den Werten der ZufallsvariablenR 1 (Koeffizient der Serienkorrelation) geht hervor, daß die statistische Schlußfolgerungy=f(n) nicht identisch werden kann mit derjenigen, die aus der Eichfunktiony=f(c) hervorgeht.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1618-2650
    Keywords: Best. von Carbonat in Wasser ; Elektroden, ionenselektive ; verbesserte Luftspaltelektrode
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The air-gap gas sensing electrode according to Růžička is improved in several aspects. The reliability was increased by the use of a combined glass-reference electrode. A new way of sample introduction gave a better accuracy in practice. The electrode is used to determine carbonate concentrations in the range of 5 · 10−2–5 · 10−4M with an accuracy of 2–9%. The electrode is in use in the analysis of environmental carbonate.
    Notes: Zusammenfassung Die Luftspaltelektrode nach Růžička wurde in einigen Punkten verbessert. Ihre Zuverlässigkeit wurde durch Anwendung einer Einstabmeßkette erhöht; ein neues System der Probezugabe bietet eine bessere Genauigkeit in der Praxis. Die Elektrode wurde zur Messung von Carbonatkonzentrationen im Betrieb von 5 · 10−2–5 · 10−4 M eingesetzt, wobei die Genauigkeit 2–9% betrug. Sie wird zur Umweltanalyse von Carbonat angewendet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1618-2650
    Keywords: Analyse von Fluormetallkomplexen ; Elektroden, ionenselektive ; Fluoridspuren als Fehlerquelle
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Anwendung der Fluoridmembran-Elektrode zur Bestimmung der Stabilitätskonstanten von Metallfluorokomplexen im NaCl(p.a.)-Medium führt zu erhöhten Werten im unteren Bereich der Komplexbildung. Dieser Fehler ist auf das Vorhandensein von Fluorid-Verunreinigungen im NaCl zurückzuführen und kann rechnerisch berücksichtigt werden. Eine Reinigung des NaCl mit Hilfe der Gegenstromelektrolyse wird beschrieben.
    Notes: Summary The use of the fluoride membrane electrode for the determination of the stability constants of metal fluoro complexes in NaCl(p.a.) medium leads to too high values, particularly in the region of small average ligand numbers. This error is caused by the fluoride contamination in NaCl and can be taken into account by calculation. The decontamination of NaCl(p.a.) by means of counter current electrolysis is described.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1618-2650
    Keywords: Elektroden, ionenselektive ; Diskelektroden, innere Ableitung, Gaselektroden, Diffusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Bei Diskelektroden bzw. Coated-Wire-Elektroden mit Pt als Festkontakt lÄ\t sich das innere Referenzsystem als Gaselektrode beschreiben. Das ursprünglich im Me\betrieb vorliegende Pt/O2-System kann durch SÄttigen der Me\lösung mit H2 in eine Pt/H2-Halbzelle umgewandelt werden. Theoretische AnsÄtze für die Gasdiffusion durch die Polymerelektrodenmembran werden miteinander verglichen. Die gemessenen Potentialeinstellkurven dienen zur Berechnung von Diffusionskoeffizienten für O2 und H2. Eine exakte Beschreibung der experimentellen Befunde sollte das Auftreten von Mischpotentialen berücksichtigen.
    Notes: Summary The internal reference system of disk electrodes or coated-wire electrodes with direct contact of Pt wire to the ion-selective membrane can be described as a gaseous electrode. Under normal conditions there exists a Pt/O2-system, which can be transferred into a stable Pt/H2-system by saturating the solution with hydrogen. Several calculations of the diffusion of gas through the PVC-membrane are compared in order to get coefficients of diffusion for oxygen and hydrogen in ion-selective membranes. The results show that mixed potentials have to be taken into consideration.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...