ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (4)
  • Institute of Physics  (4)
  • 2020-2024  (4)
  • Medicine  (4)
Collection
  • Articles  (4)
Years
Year
  • 1
    Publication Date: 2021-10-29
    Description: Purpose The aim of this study was to assess the feasibility of the development and training of a deep learning object detection model for automating the assessment of fiducial marker migration and tracking of the prostate in radiotherapy patients. Methods and Materials A fiducial marker detection model was trained on the YOLO v2 detection framework using approximately 20,000 pelvis kV projection images with fiducial markers labelled. The ability of the trained model to detect marker positions was validated by tracking the motion of markers in a respiratory phantom and comparing detection data with the expected displacement from a reference position. Marker migration was then assessed in 14 prostate radiotherapy patients using the detector for comparison with previously conducted studies. This was done by determining variations in intermarker distance between the first and subsequent fractions in each patient. Results On completion of training, a detection model was developed that operated at a 96% detection efficacy and with a root mean square error of 0.3 pixels. By determining the displacement from a reference position in a respiratory phantom, experimentally and with the detector it was found that the detector was able to compute displacements with a mean accuracy of 97.8% when compared to the actual values. Interfraction marker migration was measured in 14 patients and the average and maximum ± standard deviation marker migration were found to be 2.0±0.9 mm and 2.3±0.9 mm, respectively. Conclusion This study demonstrates the benefits of pairing deep learning object detection, and image-guided radiotherapy and how a workflow to automate the assessment of organ motion and seed migration during prostate radiotherapy can be developed. The high detection efficacy and low error make the advantages of using a pre-trained model to automate the assessment of the target volume positional variation and the migration of fiducial markers between fractions.
    Electronic ISSN: 2057-1976
    Topics: Biology , Medicine , Physics , Technology
    Published by Institute of Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2021-10-29
    Description: Purpose. To investigate indirect radiation-induced changes in airways as precursors to atelectasis post radiation therapy (RT). Methods. Three Wisconsin Miniature Swine (WMS TM ) underwent a research course of 60 Gy in 5 fractions delivered to a targeted airway/vessel in the inferior left lung. The right lung received a max point dose
    Electronic ISSN: 2057-1976
    Topics: Biology , Medicine , Physics , Technology
    Published by Institute of Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2021-10-29
    Description: Purpose: Since guidance based on X-ray imaging is an integral part of interventional procedures, continuous efforts are taken towards reducing the exposure of patients and clinical staff to ionizing radiation. Even though a reduction in the X-ray dose may lower associated radiation risks, it is likely to impair the quality of the acquired images, potentially making it more difficult for physicians to carry out their procedures. Method: We present a robust learning-based denoising strategy involving model- based simulations of low-dose X-ray images during the training phase. The method also utilizes a data-driven normalization step - based on an X-ray imaging model - to stabilize the mixed signal-dependent noise associated with X-ray images. We thoroughly analyze the method's sensitivity to a mismatch in dose levels used for training and application. We also study the impact of differing noise models used when training for low and very low-dose X-ray images on the denoising results. Results: A quantitative and qualitative analysis based on acquired phantom and clinical data has shown that the proposed learning-based strategy is stable across different dose levels and yields excellent denoising results, if an accurate noise model is applied. We also found that there can be severe artifacts when the noise characteristics of the training images are significantly different from those in the actual images to be processed. This problem can be especially acute at very low dose levels. During a thorough analysis of our experimental results, we further discovered that viewing the results from the perspective of denoising via thresholding of sub-band co efficients can be very beneficial to get a better understanding of the proposed learning-based denoising strategy. Conclusion: The proposed learning-based denoising strategy provides scope for significant X-ray dose reduction without the loss of important image information if the characteristics of noise is accurately accounted for during the training ph
    Electronic ISSN: 2057-1976
    Topics: Biology , Medicine , Physics , Technology
    Published by Institute of Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2021-10-29
    Description: Kilovoltage cone-beam computed tomography (CBCT)-based image-guided radiation therapy (IGRT) is used for daily delivery of radiation therapy, especially for stereotactic body radiation therapy (SBRT), which imposes particularly high demands for setup accuracy. The clinical applications of CBCTs are constrained, however, by poor soft tissue contrast, image artifacts, and instability of Hounsfield unit (HU) values. Here, we propose a new deep learning-based method to generate synthetic CTs (sCT) from thoracic CBCTs. A deep-learning model which integrates histogram matching (HM) into a cycle-consistent adversarial network (Cycle-GAN) framework, called HM-Cycle-GAN, was trained to learn mapping between thoracic CBCTs and paired planning CTs. Perceptual supervision was adopted to minimize blurring of tissue interfaces. An informative maximizing loss was calculated by feeding CBCT into the HM-Cycle-GAN to evaluate the image histogram matching between the planning CTs and the sCTs. The proposed algorithm was evaluated using data from 20 SBRT patients who each received 5 fractions and therefore 5 thoracic CBCTs. To reduce the effect of anatomy mismatch, original CBCT images were pre-processed via deformable image registrations with the planning CT before being used in model training and result assessment. We used planning CTs as ground truth for the derived sCTs from the correspondent co-registered CBCTs. The mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and normalized cross-correlation (NCC) indices were adapted as evaluation metrics of the proposed algorithm. Assessments were done using Cycle-GAN as the benchmark. The average MAE, PSNR, and NCC of the sCTs generated by our method were 66.2 HU, 30.3 dB, and 0.95, respectively, over all CBCT fractions. Superior image quality and reduced noise and artifact severity were seen using the proposed method compared to the results from the standard Cycle-GAN method. Our method could therefore improve the accuracy of IGRT and corrected CBCTs could help improve online adaptive RT by offering better contouring accuracy and dose calculation.
    Electronic ISSN: 2057-1976
    Topics: Biology , Medicine , Physics , Technology
    Published by Institute of Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...