ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Rietveld refinement  (2)
  • International Union of Crystallography  (2)
  • 1
    facet.materialart.
    Unknown
    International Union of Crystallography | 5 Abbey Square, Chester, Cheshire CH1 2HU, England
    Publication Date: 2021-03-30
    Description: Recently, the authors reported on the development of crystallinity in mixed‐tacticity polyhydroxybutyrates. Comparable values reported in the literature vary depending on the manner of determination, the discrepancies being partially attributable to scattering from paracrystalline portions of the material. These portions can be qualified by peak profile fitting or quantified by allocation of scattered X‐ray intensities. However, the latter requires a good quality of the former, which in turn must additionally account for peak broadening inherent in the measurement setup, and due to limited crystallite sizes and the possible presence of microstrain. Since broadening due to microstrain and paracrystalline order both scale with scattering vector, they are easily confounded. In this work, a method to directionally discern these two influences on the peak shape in a Rietveld refinement is presented. Allocating intensities to amorphous, bulk and paracrystalline portions with changing tactic disturbance provided internal validations of the obtained directional numbers. In addition, the correlation between obtained thermal factors and Young's moduli, determined in earlier work, is discussed.
    Description: A method to robustly determine paracrystalline contents from Rietveld‐refined powder X‐ray data is presented and discussed for the example of mixed‐tacticity polyhydroxybutyrates. image
    Keywords: 548 ; polyhydroxybutyrates ; mixed tacticity ; paracrystallinity ; Rietveld refinement ; thermal factors
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2023-07-21
    Description: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉The high‐intensity time‐of‐flight (TOF) neutron diffractometer POWTEX for powder and texture analysis is currently being built prior to operation in the eastern guide hall of the research reactor FRM II at Garching close to Munich, Germany. Because of the world‐wide 〈sup〉3〈/sup〉He crisis in 2009, the authors promptly initiated the development of 〈sup〉3〈/sup〉He‐free detector alternatives that are tailor‐made for the requirements of large‐area diffractometers. Herein is reported the 2017 enterprise to operate one mounting unit of the final POWTEX detector on the neutron powder diffractometer POWGEN at the Spallation Neutron Source located at Oak Ridge National Laboratory, USA. As a result, presented here are the first angular‐ and wavelength‐dependent data from the POWTEX detector, unfortunately damaged by a 50〈italic〉g〈/italic〉 shock but still operating, as well as the efforts made both to characterize the transport damage and to successfully recalibrate the voxel positions in order to yield nonetheless reliable measurements. Also described is the current data reduction process using the 〈italic〉PowderReduceP2D〈/italic〉 algorithm implemented in 〈italic〉Mantid〈/italic〉 [Arnold 〈italic〉et al.〈/italic〉 (2014). 〈italic〉Nucl. Instrum. Methods Phys. Res. A〈/italic〉, 〈bold〉764〈/bold〉, 156–166]. The final part of the data treatment chain, namely a novel multi‐dimensional refinement using a modified version of the 〈italic〉GSAS‐II〈/italic〉 software suite [〈ext-link ext-link-type="uri" xlink:href="http://scripts.iucr.org/cgi-bin/paper?aj5212"〉Toby & Von Dreele (2013). 〈italic〉J. Appl. Cryst.〈/italic〉〈bold〉46〈/bold〉, 544–549〈/ext-link〉], is compared with a standard data treatment of the same event data conventionally reduced as TOF diffraction patterns and refined with the unmodified version of 〈italic〉GSAS‐II〈/italic〉. This involves both determining the instrumental resolution parameters using POWGEN's powdered diamond standard sample and the refinement of a friendly‐user sample, BaZn(NCN)〈sub〉2〈/sub〉. Although each structural parameter on its own looks similar upon comparing the conventional (1D) and multi‐dimensional (2D) treatments, also in terms of precision, a closer view shows small but possibly significant differences. For example, the somewhat suspicious proximity of the 〈italic〉a〈/italic〉 and 〈italic〉b〈/italic〉 lattice parameters of BaZn(NCN)〈sub〉2〈/sub〉 crystallizing in 〈italic〉Pbca〈/italic〉 as resulting from the 1D refinement (0.008 Å) is five times less pronounced in the 2D refinement (0.038 Å). Similar features are found when comparing bond lengths and bond angles, 〈italic〉e.g.〈/italic〉 the two N—C—N units are less differently bent in the 1D results (173 and 175°) than in the 2D results (167 and 173°). The results are of importance not only for POWTEX but also for other neutron TOF diffractometers with large‐area detectors, like POWGEN at the SNS or the future DREAM beamline at the European Spallation Source.〈/p〉
    Description: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉The first real‐world neutron diffraction data have been collected with one of the POWTEX detectors (FRM II, Garching, Germany) mounted for testing at the Spallation Neutron Source (Oak Ridge National Laboratory, USA). They allow for angular‐ and wavelength‐dispersive Rietveld refinement using a modified version of 〈italic〉GSAS‐II〈/italic〉.〈boxed-text position="anchor" content-type="graphic" xml:lang="en"〉〈graphic position="anchor" id="jats-graphic-1" xlink:href="urn:x-wiley:16005767:jcr2tu5033:jcr2tu5033-fig-0001"〉 〈/graphic〉〈/boxed-text〉〈/p〉
    Keywords: ddc:548 ; neutron detectors ; POWGEN beamline ; POWTEX detector ; DREAM beamline ; time‐of‐flight diffraction ; angular‐dispersive refinement ; wavelength‐dispersive refinement ; powder diffraction ; Rietveld refinement ; multi‐dimensional refinement
    Language: English
    Type: doc-type:article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...