ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Gas chromatography  (70)
  • Wiley-Blackwell  (70)
  • 1975-1979  (70)
  • 1940-1944
  • 11
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 400-404 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Low temperature plasma etching ; Polymer film on the inner surface from organosilicone monomer ; Flexibility of this new method discussed ; Discharge chamber described ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A novel method is described for the preparation of stable glass capillary columns (glass open tubular columns), including the etching and formation of a polymer film on the inner glass capillary surfaces. The approach used here is based on low-temperature plasma etching and polymerization. Under the influence of a field of radio frequency discharge, low pressure gases of fluoric compounds, introduced into the glass capillary tube, generate excited fluorine radicals which etch the inner surface. The plasma of organosilicone monomer in the glass capillary yields a uniform polymerized film on the inner surface. The resultant material functions as a good stationary phase for glass capillary gas chromatography (GC2). The inner surfaces treated with such a plasma, can be studied by means of a scanning electron microscope (SEM). The flexibility of this method permits the use of various stationary phases and surface modification.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 416-422 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; SECAT-technique=stepless fine tuning of capillary selectivity by serial column temperature optimization ; Exponential influence of temperature on selectivity over a wide range found ; SECAT-technique ready for automation of column adjustment on sample composition polarity ; Instrumental and methodological details for primitive self made solution given ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: GC, including capillary GC, is rather inflexible, if a certain column length and stationary phase has been fixed for a given analytical problem. If the sample composition changes, one often has to change the column length and/or stationary phase, at least when something like optimum analytical conditions are needed. Temperature changes (or heating rates) can change the selectivity of a given column only within very limited ranges, due to the exponential effect of temperature on retention time. By serial coupling two chemically different capillaries, each run at another temperature, even the slightest changes of these two temperature values have a dramatic effect on the selectivity of the system for polar substances. We call this technique the SECAT mode of GC. Results are reported as retention index shifts, dependent on SECAT temperature data. This technique can in future easily be automated, thus enabling the analyst, for polar sample analysis, to adjust a given chroma-tographic system to his specific sample composition without touching the instrument.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 487-496 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Comparison of FID, ECD, FPD for detection limit. linearity, peak shape etc. ; Practical results for pesticide residue and coal hydrogenation products given ; Concentration dependent detectors in capillary GC interesting, when optimized ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A comparison of the characteristics and Performance of the flame ionization, electron capture, and flame photometric detectors with capillary columns is described. Factors which may affect the limits of detection, linearity, chromatographic peak shape, and other detector performance characteristics are discussed and compared with the results of a model derived for the behavior of concentration and mass flow-rate dependent chromatographic detectors used with capillary GC systems. Examples are given of highly complex and labile mixtures such as pesticide residues and products from coal hydrogenation.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 581-582 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Retention indices and substituent constants ; Phenols ; Polar stationary phases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface deactivation, persllylation ; Discussion of variable parameters ; Suggested practical procedure ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 629-630 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary glass ; Nitrogen-specific detection ; TMSN ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 31-35 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface deactivation, silylation ; Inertia stable to 350° ; Free acids and bases, simultaneous injection ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A deactivation procedure is described based on a published method using hexamethyldisilazane in the gas phase. In addition to unusually high inertia and thermostability, the method produces truly neutral columns which allow simultaneous analysis of moderately strong free acids and bases. The silylated columns show their full potential only with on-column injection. Preliminary experimental directions are given; more elaborate directions will become available after extended optimization work.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 529-530 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Requirements with respect to pressure controllers ; Design of pressure controllers ; All-metal controllers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 186-186 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Carrier gas ; Flow control by flattened tube restriction ; Fine tuning by adjustable twisting ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 187-188 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Whiskers, OV-17 ; Steroid profiling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...