ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Physics  (2,657)
  • Gas chromatography  (285)
  • Wiley-Blackwell  (2,942)
  • American Physical Society (APS)
  • 1980-1984  (2,942)
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 248-252 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Column loadability - overload phenomenon ; Non-classical approach to theory of loadability ; Effect on retention times, peak shape ; Effect of column length ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The usual concepts of the dynamics of an overloaded solute band fail to explain several phenomena such as the typical “leading-tail” shape and retention deviations exhibited by overloaded peaks, and why these defects are more commonly observed in short columns. These and other related deviations from theory can be rationalized by a non-classical approach to the overloading phenomenon.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 286-290 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; Discrimination due to FID ; Effect of carrier gas flow changes on detector sensitivity ; Hydrogen as carrier gas ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The sensitivity of an FID may change when the carrier gas flow rate changes during a chromatographic run. Sample parts which are eluted at reduced FID sensitivity produce a reduced peak area, hence are discriminated as compared to other components. Sensitivity changes were studied for hydrogen as carrier gas. For the detector tested, differences in the carrier gas flow rates of 1 ml/min shifted the FID sensitivity by 1 to 5% (depending on the fuel gas supply). Thus the stability of the sensitivity is no longer ensured as soon as the carrier gas flow rate is changed manually or by an automatic programmer during an analysis. Sensitivity drifts may also occur during temperature programmed runs with a pressure regulated carrier gas supply since the gas flow through the capillary drops with increasing temperature. Such shifts in the response became noticeable as soon as relatively high carrier gas flow rates combined with long range temperature programmes were used. The typical patterns of such discriminations are shown, closing with a discussion on the possibilities for minimizing such undesired effects.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 301-302 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Polychlorinated biphenyls ; Liquid crystal phase ; Choice of stationary phases for analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 351-352 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Injector ; Concentrator ; Electrically heated inlet ; Capillary columns ; Vapor sampler ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 537-544 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Chromatographic properties of glass surfaces ; Fluorad FC 431 ; Glass capillary GC of basic compounds ; Modification of glass surfaces ; Deactivation of glass surfaces ; Acid-base behaviour of GC columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: “Leaching” or “etching” by strong mineral acids seems to be a necessary pretreatment step for the most commonly used deactivation procedures of glass capillaries by reaction with either polyethylene glycol or silylation reagents. The acidic sites which are formed on the surface during this acid treatment cannot be completely removed by the subsequent deactivation process. This drawback can be overcome by performing the leaching with water vapour, resulting in an accumulation of cations at the surface and a decrease in the number of silanol groups. Capillaries of this type show excellent properties for the chromatography of strongly basic compounds. After the wash-out of the alkaline surface layer, the acidity of the support is suited for the chromatography of strongly basic as well as strongly acidic compounds. Due to a lack of reactive acidic sites, special deactivation procedures have to be applied to capillaries produced in this way.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 583-584 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; (Fused silica) capillary columns ; Intermediate test ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 11-16 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; SCOT column ; Coating, liquid phase ; Single-step coating ; Phenols ; Phenolic acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A single-step coating method for the preparation of glass capillary SCOT columns is described. It is reproducible and less time-consuming than the well-known two-step coating procedures. Other methods attempted are discussed briefly. Both the flame ionization and electron capture detectors could be used in conjunction with temperature programming. The separations achieved with an “activity mixture”, phenols and phenolic acids, illustrate the resolution obtained. The columns are suitable for quantitative determinations and a comparison is made with a conventional packed column.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 87-88 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, wide-bore glass WCOT ; Fourier Transform Infrared/glass capillary GC on-the-fly ; Coupling successful ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: By the use of a wide-bore WCOT capillary column, it was possible to obtain the first on-the-fly GC/FT-IR spectra with a WCOT column. This wide-bore WCOT column gave improved separation, as compared to a SCOT column, and yielded identifiable infrared spectra for a real sample.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 124-128 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Series-coupled chemically differing columns ; Fundamental studies on the properties for basic theory started ; Retention time and separation efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Basic expressions are derived for both the retention time and the effective separation factor in serially coupled GC columns. The retention time is determined by two main parameters. The first is the fractional time spent by an unretarded solute in each column which, in turn, is determined by the relative column lengths and flow velocities through each column. The second parameter is the relative mass distribution coefficient of a particular solute in each column; a variable that can be adjusted by changing the relative temperatures of the columns. The expression for the effective separation factor relates the measured separation factor for the series combination to the separation factors on the individual columns, the fractional time spent by an unretarded peak in each column, as well as the relative values of the mass distribution coefficients of a particular solute on the different columns.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Preparation of deactivated capillaries for routine analysis ; Easy deactivation and pretreatment steps described in detail ; Comparison of different modes given ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new surface pretreatment for the preparation of wall-coated open tubular (WCOT) glass capillary columns has been evaluated. This technique involves the application of a non-extractable layer of Superox™-4, a 4,000,000 MW polyethylene glycol, to the glass surface as a pretreatment and deactivation agent. Unlike other polyethylene glycols, Superox-4 is stable at high temperatures (〉 300°C) in the absence of oxygen, coats smoothly onto a bare glass surface and resists droplet formation. WCOT columns (SE-54, Carbowax 20M, and SP-2250) prepared using this technique are compared to columns prepared using a modified Grob [2,3] BaCO3 procedure. The Superox-4 pretreated columns were equal or superior in quality to the BaCO3 pretreated columns, based on the appearance of an activity standard and the effective theoretical plates (Neff) per meter. Chromatograms showing practical application of the WCOT columns prepared using both methods is given.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...