ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Naturwissenschaften 80 (1993), S. 57-64 
    ISSN: 1432-1904
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of ornithology 134 (1993), S. 199-204 
    ISSN: 1439-0361
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Description / Table of Contents: Summary In 1985–1992 the dynamics of local bird communities were studied by year-round transect counts in an area of the northern Alps (800–1000 m asl.; Bavaria). The total of families (adults with fledglings) over all species per year was nearly constant within five successive years. In 1992 the number of families was extremely high, whereas in 1991 the lowest total was registered. Over eight years no correlation between total of families and abundance values in May could be found. This means, that higher production was not due to higher density of breeding pairs in spring. However, in 1992 the May was extremely warm and dry, whereas during May 1991 the lowest mean temperature and and the most days with snowfall within the study period could be registered. The abundance in June fluctuating within a rather low range was correlated with the total of families. For July and August, however, only a very weak correlation was found indicating that a higher production of young was eliminated from the study plots either by dismigration or by higher juvenile mortality. Monitoring weather effects on bird communities as well as on populations in long-term studies my be important to analyse the influence of predicted global warming.
    Notes: Zusammenfassung Die Zahl der registrierten Vogelfamilien (ad. und noch nicht selbständige, eben flügge Jungvögel) auf einer Kontrollfläche in den bayerischen Nordalpen war 1986–1990 konstant, lag 1985 über dem Mittel, war 1991 am niedrigsten und erreichte 1992 ein Maximum. Eine Korrelation zwischen Familien und Abundanzwerten im Mai bestand nicht. Dagegen fiel das Maximaljahr mit einem außergewöhnlich trockenen und warmen Mai zusammen, das vorausgehende Minimumjahr mit einem außergewöhnlich kühlen und relativ feuchten Mai mit den meisten Schneetagen während des Untersuchungszeitraums. Die Zahl der Familien war mit einer Erhöhung der in einzelnen Jahren jedoch nicht sehr auffällig variierenden Abundanz im Juni korreliert. Auf die Abundanz im Juli und August schien die Produktion an Jungen nur noch geringen Einfluß zu haben. Dies würde bedeuten, daß Dismigration oder Jungvogelverluste die lokale Individuendichte regulierten. Monitoring von abweichenden Witterungsverhältnisse und ihrer Einflüssen auf Vogelgesellschaften und-populationen könnte Bedeutung für die Abschätzung des Treibhauseffektes bekommen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Heat and mass transfer 27 (1992), S. 249-257 
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Zusammenfassung In dieser Untersuchung wurde die Verbesserung des Wärmeübergangs in viskosen Flüssigkeitsströmungen mittels eines Spiralband-Einsatzes erforscht. Es wurden Strömungen in horizontalen Rohren mit einheitlicher Wandtemperatur betrachtet. Diese sind repräsentativ für typische Bedingungen, die in praktischen Anwendungen in der chemischen und weiterverarbeitenden Industrie anzutreffen sind. Für Wasser und Äthylen-Glykol wurden experimentelle Daten für eingepaßte Band-Einsätze mit drei unterschiedlichen Verdrehungsverhältnisseny=3.0, 4.5 und 6.0 erhalten; die Breite des Bandes betrug jeweils 0.483 mm. Die Daten decken einen weiten Bereich von Strömungsparametern ab: 3.5〈Pr〈100 und 300〈Re〈35,000 für die beiden Betriebsbedingungen Heizen und Kühlen. Die Ergebnisse fürNu m undf sind stark abhängig von der Bandgeometrie und den Strömungsbedingungen und können zweckmäßig durchNu m=φ(Re, Pr, μ b/μw,L/d, H/d, δ/d) undf=φ(Re, H/d, δ/d) dargestellt werden.
    Notes: Abstract Heat transfer enhancement in viscous liquid flows by means of twisted-tape inserts has been investigated in this study. Internal flows in horizontal tubes with uniform wall temperature have been considered. This is representative of typical conditions encountered in practical applications in the chemical and process industry. Experimental data were obtained for water and ehtylene glycol with snug-fit tape inserts of three different twist ratios,y=3.0, 4.5, and 6.0; the tape thickness in each case was 0.483 mm. The data cover a wide range of flow parameters: 3.5〈Pr〈100, and 300〈Re〈35,000, for both heating and cooling conditions. The results forNu m andf are strongly influenced by the tape geometry and fluid flow conditions, and can be functionally represented byNu m=φ(Re, Pr, μ b/μw,L/d, H/d, δ/d) andf=φ(Re, H/d, δ/d).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Heat and mass transfer 27 (1992), S. 437-446 
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Zusammenfassung Es wird die analytische Studie des Wärmeübergangs (freie Konvektion, begrenzte viskose Dissipation) bei mit Potenzansatz beschriebenen Fluiden in Rohrleitungen mit verschiedenen Querschnitten durchgeführt. Die Strömung und der Wärmeübergang entwickeln sich gleichzeitig ab dem Eingang der Leitungen. Die Wände der Rohrleitungen werden auf konstanter Temperatur gehalten, welche ungleich der Temperatur der einströmenden Flüssigkeiten ist. Die in Gaußschen Koordinaten geschriebenen Erhaltungsgleichungen werden mit der LSOR-(Line-Successive-Over-Relaxation-) Methode gelöst. Die numerischen Ergebnisse der dimensionslosen Wärmeübergangskoeffizienten und der Temperaturprofile werden für trapezförmige, dreieckige und runde Querschnitte vorgelegt. Beim Kühlen erhöht die viskose Dissipation in der Regel den Wärmeübergang. Bei kleinen Brinkman-Zahlen (Br∼0,1) dominieren die Kühlungseffekte über das viskose Aufheizen im Einlaufbereich. Wenn die Br-Zahlen erhöht werden, verschiebt sich die Gegend, in der die viskosen Effekte überwiegen, in Richtung Einlauf solange, bis eine Br-Zahl erreicht wird, bei der die Dissipation, unabhängig von der axialen Entfernung, immer dominant ist. Wenn die Wände bei Br-Zahlen ungleich Null beheizt werden, weist dieNu X*-Verteilung eine Singularität auf der negativen Seite derNu X*-Achse auf. Wenn der Index des Potenzansatzes steigt, nähert sich die Singularität dem Einlauf der Rohrleitung. Weit strömungsabwärts, für ein festesn, nimmtNu X*, unabhängig von der Br-Zahl, asymptotische Werte an. Diese Werte erreichen das Dreifache derjenigen für erzwungene Konvektion ohne viskose Dissipation.
    Notes: Abstract In this paper, the analytical study of forced convection heat transfer to power-law fluids in arbitrary cross-sectional ducts with finite viscous dissipation is undertaken. Both the flow and heat transfer develop simultaneously from the entrance of the duct the walls of which are maintained at a constant temperature different from the entering fluid temperature. The governing conservation equations written in curvilinear coordinates are solved using the Line-Successive-Over relaxation (LSOR) method. Numerical results of dimensionless heat transfer coefficients and temperature profiles are presented for the trapezoidal, triangular, circular and square ducts. For cooling, viscous dissipation generally augments heat transfer. At low values of Brinkman number (Br∼0.1), the cooling effect dominates over viscous heating in the entrance region. AsBr is increased, the location where viscous dissipation becomes important shifts closer to the entrance until a value is reached for which the effect of viscous dissipation is always predominant irrespective of the axial location. When the walls are heated, for a non-zero Brinkman number, theNu X* distribution exhibits a singularity from the negative side of theNu X* axis. As the power-law index increases, the position of this singularity shifts closer to the entrance of the duct. Far downstream of the duct, for a fixedn, Nu X* attains an asymptotic value which is independent ofBr and is at least thrice that for forced convection without viscous dissipation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...