ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY
  • SPACE RADIATION
  • 1990-1994  (1,947)
  • 1960-1964  (939)
  • 1900-1904  (1)
Collection
Years
Year
  • 1
    Publication Date: 2019-08-28
    Description: We analyze duration and brightness distributions of both the SIGNE Venera 13 and 14 and Burst and Transient Source Experiment (BATSE) gamma-ray burst databases. Choosing T(sub 50) as a measure of the burst duration and using both 64 and 1024 ms peak count rates, we search for correlations between duration, peak brightness, and the ratio V identically equals C(sub 64)/C(sub 1024), proposed as a measure of variability by Lamb, Graziani, & Smith. The duration histogram for SIGNE shows a long-duration peak that is consistent with BATSE, but does not exhibit the short population, instead appearing flat below 0.6 s; the difference is presumably caused by the failure of SIGNE to detect the short, faint bursts that were observed by BATSE. Estimating the instantaneous brightness by C(sub 64), we find that SIGNE confirms the BATSE result that the long and short bursts have similar maximum instantaneous brightnesses. Scatterplots between duration, brightness, and V are consistent for both databases; we show that SIGNE confirms the BATSE observation that there is a lack of bursts that are both bright over 1024 ms and contain a short, bright spike.
    Keywords: SPACE RADIATION
    Type: Astrophysical Journal, Part 2 - Letters (ISSN 0004-637X); 421; 2; p. L83-L86
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-08-28
    Description: The properties and the expected performance of a liquid xenon (LXe) gamma-ray imaging telescope, optimized for the MeV energy region, are presented. The unique potential of this telescope as a Compton polarimeter is particularly emphasized. Based on Monte Carlo simulations, we show that the modulation factor is as high as 40% at 1 MeV with a detection efficiency close to 20%. These figures of merit, combined with the excellent background suppression capability of the three-dimensional position sensitive LXe detector, yield sensitivity at the 3 sigma level to polarization fractions as small as a few percent for strong sources, even in a balloon flight.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Astrophysical Journal Supplement Series (ISSN 0067-0049); 92; 2; p. 689-691
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-08-28
    Description: The Oriented Scintillation Spectrometer Experiment (OSSE) on the Compton Observatory observed SN 1993J during three intervals centered approximately 12, 30, and 108 days after its outburst. Hard X-ray emission was detected in the first two of these intervals. No emission was seen in the third observation or in two earlier observations in 1991 and 1992. The coincidence of the observed excess with the outburst of SN 1993J and the consistency of the spectra and time evolution with those seen at lower energies by ROSAT and ASCA (Astro-D) argue that the observed emission is indeed from SN 1993J. It is probably due to the interaction of the fast supernova ejecta with circumstellar material. The luminosity, 5 x 10(exp 40) ergs/sec (50-150 keV) in the first interval, is significantly larger than predicted. Extrapolating the spectrum to a few keV accounts for most or all of the observed emission at low energy. The observed high temperature, 10(exp 9) K, is easily obtained in the shocked circumstellar matter, but a surprisingly high density is required there to give the observed luminosity, and little or no additional X-ray emission from denser shocked supernova ejecta is allowed. The hard emission might also be explained in terms of the shocked supernova ejecta itself with unexpectedly high temperature.
    Keywords: SPACE RADIATION
    Type: The Astrophysical Journal (ISSN 0004-637X); 431; 2, pt; p. L95-L98
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-08-28
    Description: The Anuradha cosmic ray experiment in Spacelab-3, flown in the orbit at 350 km with an inclination of 57 deg for about six days, was used to measure the low energy galactic cosmic ray (GCR) heavy ions using a specially designed CR-39 detector module incorporating the arrival time information of the particles. The abundances of sub-iron (Sc-Cr) and iron particles in the low energy interval of 30-300 MeV/N were determined from the measurements made in four different depths of the Cr-39 detector module of 150 layers. From these studies we obtained sub-iron (Sc-Cr) to iron abundance ratios of 0.8 to 1.2 in 30-300 MeV/N energy range. It is found that these ratios are enhanced by a factor of two as compared to interplanetary ratios of about 0.5. It is shown that the enhancement of the ratio inside the earth's magnetosphere is probably due to the degree of ionization of low energy Sc to Cr and Fe ions in the galactic cosmic rays and to the rigidity filtering effects of the geomagnetic field. Further studies are needed to understand fully the phenomena and their implications.
    Keywords: SPACE RADIATION
    Type: Journal of Astrophysics and Astronomy (ISSN 0250-6335); 15; 1; p. 85-94
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-08-28
    Description: We have fabricated and characterized six-element monolithic arrays of Ge:Ga blocked-impurity-band detectors, with threshold wavelength 220 microns, peak quantum efficiency 14 percent, detective quantum efficiency 9 percent, dark current 300 e(-)/s, and response uniformity better than 4 percent. The devices are described very well by the standard model of blocked-impurity-band detectors and appear to satisfy many of the requirements of low-background astronomical instruments.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Applied Physics (ISSN 0021-8979); 74; 6; p. 4199-4206.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-08-28
    Description: Abundances of chlorine oxide (ClO) have been measured from 16 km to 30 km by a new balloon-borne in situ instrument developed from an optical design flown previously on the NASA ER-2 aircraft. This instrument, a prototype for one to be flown on the Perseus remotely piloted aircraft, was one-third the weight of that on the ER-2, yet retained the high precision and accuracy necessary for detailed photochemical studies of the lower stratosphere. In this paper we discuss the performance of the instrument during its first flight on March 31, 1991 over eastern New Mexico.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Geophysical Research Letters (ISSN 0094-8276); 20; 17; p. 1791-1794.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2019-08-28
    Description: This video presents great model photography along with astronaut activity as practiced in mockup.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: ASR-253 , NASA-TM-109636 , NONP-NASA-VT-93-190434
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-08-28
    Description: We describe a multiplexed, laser-induced fluorescence (LIF) technique with which radial and axial profiles of vector velocities of excited propellant species were obtained in the exhaust plume from a 300-W argon arcjet. Although the arcjet is a prototype, and although argon is not an interesting propellant from a propulsion perspective, the technique clearly demonstrates how a narrowband, frequency-stabilized ring-dye laser can be used to obtain simultaneous measurements of two velocity components in an arcjet plume and how a third signal from an optogalvanic cell can be used as a frequency reference. We also show that much information on the flow can be obtained by analyzing the Doppler widths and fluorescence intensities of the LIF data. Specifically, the data identify a boundary layer in the radial direction of the plume and a shock in the downstream region of the flow. Also, some flow anisotropy is observed, consistent with the assumption that the magnitude of the mean flow velocity fluctuates. The peak velocity on centerline remains roughly constant at 3 km/s throughout the expansion.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: AIAA Journal (ISSN 0001-1452); 31; 11; p. 2083-2089.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-08-28
    Description: On 1989 May 22, the High Energy X-ray and Gamma-ray Observatory for Nuclear Emissions, a balloon-borne high-resolution germanium spectrometer with an 18-deg FOV, observed the Galactic Center (GC) from 25 to 2500 keV. The GC photon spectrum is obtained from the count spectrum by a model-independent method which accounts for the effects of passive material in the instrument and scattering in the atmosphere. Besides a positron annihilation line with a flux of (10.0 +/- 2.4) x 10 exp -4 photons/sq cm s and a full width at half-maximum (FWHM) of (2.9 + 1.0, -1.1) keV, the spectrum shows a peak centered at (163.7 +/- 3.4) keV with a flux of (1.55 +/- 0.47) x 10 exp -3 photons/sq cm s and a FWHM of (24.4 +/- 9.2) keV. The energy range 450-507 keV shows no positronium continuum associated with the annihilation line, with a 2-sigma upper limit of 0.90 on the positronium fraction. The 164 keV feature is interpreted as Compton backscatter of broadened and redshifted annihilation radiation, possibly from the source 1E 1740.7-2942.
    Keywords: SPACE RADIATION
    Type: Astrophysical Journal, Part 1 (ISSN 0004-637X); 414; 1; p. 165-177.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-08-28
    Description: The performance of a sensor is often evaluated by determining to what degree of accuracy a measurement can be made using this sensor. The absolute accuracy of a sensor is an important parameter considered when choosing the type of sensor to use in research experiments. Tests were performed to improve the accuracy of cryogenic temperature measurements by calibration of the temperature sensors when installed in their experimental operating environment. The calibration information was then used to correct for temperature sensor measurement errors by adjusting the data acquisition system software. This paper describes a method to improve the accuracy of cryogenic temperature measurements using corrections in the data acquisition system software such that the uncertainty of an individual temperature sensor is improved from plus or minus 0.90 deg R to plus or minus 0.20 deg R over a specified range.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: International Instrumentation Symposium, 39th, Albuquerque, NM, May 2-6, 1993, Proceedings (A93-54351 24-35); p. 213-226.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...