ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Column liquid chromatography  (523)
  • Springer  (523)
  • American Meteorological Society
  • Springer Nature
  • 1990-1994  (495)
  • 1980-1984  (28)
  • 1965-1969
Collection
Publisher
  • Springer  (523)
  • American Meteorological Society
  • Springer Nature
  • Wiley-Blackwell  (5)
Years
Year
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Aromatic acid isomers ; Low capacity ion-exchange resin ; Microbore packed columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A low-capacity, anion-exchange, porous-polymer resin was used as the packing material in a microbore column. Using a phosphate buffer containing various organic modifiers, retention behavior of substituted benzoic acid isomers with amino, chloro, methyl, nitro and carboxylic groups was investigated. The effect of ethanol, acetonitrile and sodium dodecylsulfate used as organic modifiers on the retention behavior at various eluent pH values was studies and optimum separations of the positional isomers reported.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 668-672 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Mixed eluents ; Preferential sorption of eluents ; Pressure effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Pronounced base line perturbations were repeatably observed in LC both in alternating recycling and in backflushing experiments when binary eluents and refractometric detectors were used. The perturbations which we call eigenzones appeared immediately after operating the recycling or the backflushing valve, and their size and shape depended on the nature of both the column filling and the mixed mobile phase as well as on the pressure drop across the column. Experimental results presented confirm that the primary causes of the eigenzones were the pressure changes in the columns which influenced the sorption equilibrium of mixed eluent components within the column packing. Some practical consequences of this effect are briefly discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Polycyclic aromatic hydrocarbons ; Column liquid chromatography ; Polyphenyl bonded phases ; Retention and carbon content
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The relationship between the retention of PAHs having various molecular sizes and the carbon contents (%) of bonded stationary phases with various types of ligands were investigated. The examined stationary phases were phenyl, diphenyl, triphenyl and benzyl-bonded silicas. The data indicated that sometimes it is not true that the retention of any solute relates linearly to the carbon content of the stationary phase. As the result, it is suggested that the pore size distribution of the silica support, the bulkiness of the ligand bonded to the silica and the molecular size of solute should also be considered before any precise statement can be made.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 175-182 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Fourier transform IR ; Polar compounds ; Coal products
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Fourier-transform infrared spectrometry (FTIR) was utilized as a detection system for high-performance liquid chromatography of polar compounds on a normal bonded-phase system. In addition to FTIR, UV (254 nm) and refractive index detection were employed in the separation of model compounds containing oxygen and nitrogen atoms in their molecules (phenols, alcohols, neutral and weakly basic nitrogen compounds). A polar amino-cyano (PAC) bonded-phase column was employed with a binary mobile phase (98:2 CDCl3:CH3CN). The separations and the information gained from each detector is discussed, including interactions between sample material and mobile phase. A polar fraction of a coal-derived product is also chromatographed under identical conditions. The results based on FTIR detection and chromatographic retention behavior suggest the exclusive presence of hindered and unhindered phenols.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 211-215 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Alkylbenzenes ; PAHs ; Retention prediction ; Microcomputer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The microcomputer-assisted retention prediction system in C18 reversed-phase HPLC is described. The system is based on the use of the hydrophobic parameter and the correlation factor of alkylbenzenes and polycyclic aromatic hydrocarbons (PAHs) which are highly correlated to their retention in reversed-phase HPLC. The system is evaluated by comparing the retention data between measured and predicted values. One of the typical examples applied for PAH analysis in the extracts of diesel particulate matter shows the high potential of the system investigated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 216-220 
    ISSN: 1612-1112
    Keywords: Cation exchangers ; Column liquid chromatography ; Exchange capacity, determination ; Organic peroxidation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two oxidation procedures for the synthesis of silicabased aliphatic sulfonic acid cation-exchangers for HPLC are described. Several reaction conditions for oxidizing a terminal-bonded thiol with organic peroxides are provided along with their yields, capacities, reproducibility, and chromatographic behavior. Also, three methods for determining exchange capacity are discussed, and their relationship to the capacity factors of charged solutes is compared. The maximum capacity determined by the titration of the bonded silica was 0.34 meq/gram. The general problems of synthesizing cation-exchangers, measuring their efficiencies and exchange capacities, and evaluating their overall performances are outlined.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 369-373 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ion exchange ; dynamic ; Metal ions ; Equilibria effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Equilibria occurring during the dynamic ion exchange separation of metal ions were examined, and their effect on the chromatography of the metal ions was evaluated. Bonded reversed-phase silica, pure organic reversed phase, and silica columns were used to differentiate between the role of silica and the reverse phase. The results show that system peaks had the most important influence on the applicability of dynamic exchangers to quantitative metal ion determinations. The response of system peaks to sample composition (pH, ionic strength, matrix effects) was complicated and could not be predicted easily. Equilibria effects that can cause analytical errors were identified and recommendations for elimination of such errors are given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Amines ; Phenols ; Fourier transform I.R.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Several chromatographic parameters have been examined as to their effect on detectability for microbore high-performance liquid chromatography coupled with Fourier-transform infrared spectrometry. Detection limits for several compound classes are presented as amount injected. Improvements in detectability for this technique are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polystyrene packings ; Pre-column derivatization ; Thiamine compounds ; UV and fluorescence detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The chromatography of thiochrome and related phosphate esters was studied on two different polystyrene packing materials. The adsorbents were compared with respect to capacity factors, plate heights and resolution factors measured with different mixtures of phosphate buffer (pH 8.5) and methanol. In contrast with derivatized silica, these phases were found to be stable using an alkaline mobile phase and sample. Fast separations were possible with good peak symmetry at all organic modifier concentrations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 445-448 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Amino-bonded stationary phase ; Ion-exchange ; Fermentation solution ; Biomass
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In this work the analytical separation of biomass hydrolysis and fermentation products is described. Aminobonded phase and ion exchange materials (HPX 87H, HPX 42A, μ Spherogel Carbohydrate) were used as HPLC stationary phases for the determination of monomeric and oligomeric carbohydrates, carbohydrate degradation and fermentation products. The HPX 42A and the amino-bonded phase columns are especially suitable for the analysis of the gluco oligomers. The HPX 87H column separates the monomeric sugars and their degradation and fermentation products (e.g. furfurals and ethanol) very well. Using the μ Spherogel Carbohydrate column the lower gluco-oligomers as well as the monomeric sugars and their degradation and fermentation products, can be determined within 35 minutes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...