ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (1,870)
  • Other Sources
  • American Geophysical Union  (1,688)
  • Munksgaard International Publishers  (182)
  • 1995-1999  (1,870)
  • Architecture, Civil Engineering, Surveying  (1,870)
Collection
  • Articles  (1,870)
  • Other Sources
Years
Year
Journal
Topic
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 9 (1999), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract In laboratory experiments, we investigated two task/ambient conditioning systems with air supplied from desk-mounted air outlets to efficiently ventilate the breathing zone of heated manikins seated at desks. In most experiments, the task conditioning systems provided outside air while a conventional ventilation system provided additional space cooling but no outside air. Air change effectiveness (i.e., exhaust air age divided by age of air at the manikin's face) was measured with a tracer gas step-up procedure. Other tracer gases simulated the release of pollutants from nearby occupants and from the floor covering, and the associated pollutant removal efficiencies (i.e., exhaust air concentrations divided by concentrations at manikin's face) were calculated. High values of air change effectiveness (∼1.3 to 1.9) and high values of pollutant removal efficiency (∼1.2 to 1.6) were measured when these task conditioning systems supplied 100% outdoor air at a flow rate of 7 to 9 L s-1 per occupant. Air change effectiveness was reasonably well correlated with the pollutant removal efficiency. Overall, the experimental data suggest that these task/ambient conditioning systems can be used to improve ventilation and air quality or to save energy while maintaining a typical level of IAQ at the breathing zone.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 9 (1999), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract Sixteen flights had been investigated for indoor air quality (IAQ) on Cathay Pacific aircraft from June 1996 to August 1997. In general, the air quality on Cathay Pacific aircraft was within relevant air quality standards because the average age of aircraft was less than 2 years. Carbon dioxide (CO2) levels on all flights measured were below the Federal Aviation Administration (FAA) standard (30,000 ppm). The CO2 level was substantially higher during boarding and de-boarding than cruise due to low fresh air supply. Humidity on the aircraft was low, especially for long-haul flights. Minimum humidity during cruise was below the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) minimum humidity standard (20%). The average temperature was within a comfortable temperature range of 23±2°C. The vertical temperature profile on aircraft was uniform and below the International Standard Organization (ISO) standard. Carbon monoxide levels were below the FAA standard (50 ppm). Trace amount of ozone detected ranged from undetectable to 90 ppb, which was below the FAA standard. Particulate level was low for most non-smoking flights, but peaks were observed during boarding and de-boarding. The average particulate level in smoking flights (138 (ig/m3) was higher than non-smoking flights (7.6 μg/m3). The impact on IAQ by switching from low-mode to high-mode ventilation showed a reduction in CO2 levels, temperature, and relative humidity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 9 (1999), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract The chemical and sensory emissions from five building materials (carpet, polyvinyl chloride (PVC) flooring, sealant, floor varnish and wall paint) were tested under different combinations of temperature and relative humidity in the ranges 18–28°C and 30–70% relative humidity (RH). The experiment was performed in a climate chamber where a specially designed test system was built to study emissions from the five materials. The test system could provide different temperatures and humidities of air around the materials, while the air, after being polluted by the emissions from the materials, could be reconditioned to 23°C and 50% RH for sensory assessments. The experiment was designed to separate the direct impact of temperature and humidity on perception from the impact on sensory emission. The study found little influence of temperature on the emissions from the five materials whether expressed in chemical or sensory terms. The effect of humidity was found to be significant only for the waterborne materials – floor varnish and wall paint. Compared with the direct impact of temperature and humidity on the perception of air quality, the impact of temperature and humidity on sensory emissions from the building materials has a secondary influence on perceived air quality.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 9 (1999), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract Volatile organic emissions from particleboard, medium density fibreboard (MDF) and office furniture have been measured in dynamic environmental chambers, both small and room-sized. Characterisation of product emission properties in small chambers was possible when inter- and intra-sheet variations were considered. Formaldehyde emission factors for all products were approximately double European low-emission specifications and did not decay to the latter for several months. Long-term emission behaviour could not be predicted from short-term measurements. Volatile organic compounds (VOC) emissions were low for the MDF product, higher for particleboard, and highest for laminated office furniture. The compounds emitted differed from those reported in other countries. VOC emissions from the sheet products decreased more quickly than formaldehyde, reaching low levels within two weeks, except for MDF which was found to become a low-level source of hexanal after several months.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 9 (1999), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract Birch and grass pollen grains as well as pollen-derived small particles appear as potent allergens in the outdoor air during spring and summer. The occurrence of pollen allergens in indoor air, however, has not been studied in depth due to lack of suitable sampling and analytical methods. Herein, a recently reported “direct on sampling filter estimation” (DOSAFE) technique (Acevedo et al., 1998) has been validated for quantification of pollen allergens in indoor air using two school rooms and two office rooms as experimental models. Using DOSAFE and polyclonal antibodies against water extracts of pollen from Betula pendula and Phleum pratense L, we found that indoor air of school and office rooms carried substantial amounts of pollen allergens, expressed as SQ units, predominantly occurring as particles with smaller diameters than the pollen grains. In one school room the indoor air birch pollen allergen concentrations increased from 242 to 403 SQ units/m3 over the sampling period although the corresponding outdoor air concentrations decreased from 350 to 90 SQ units/m3. Electrostatic air cleaning in one office room reduced its grass pollen allergen concentrations by more than 95% to 0.02–0.34 SQ units/m3 as compared to the control room.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 9 (1999), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract Polyurethane products were subjected to chamber testing to determine their emission rates of 2,4- and 2,6-toluene diisocyanate (TDI). The polyurethane (PU) products included carpet padding, furniture cushions, sheet foam, varnishes, and sealants, as well as a commercially-applied water sealant product for concrete that contained up to 4 percent TDI by weight. The PU products were screened in a 9-L glass chamber, under elevated temperature and chamber loading conditions, using both a time-integrated sampling and analysis method specific for TDI and a continuous but non-specific real-time monitor for isocyanates. None of the products normally found in residences showed a positive response in the screening tests, indicating that TDI emissions and consequently toxic effects from such products are negligible. However, the commercially-applied water sealant gave a positive response in the screening test. Further testing of that product at realistic temperatures showed initial TDI emission rates of about 300,000 μg/m2/hr, with emissions lasting only one hour or less. At 21 and 27°C, about 1 percent and 5 percent, respectively, of the TDI content of the product was released to the air. The emitted TDI was predominantly the 2,6-isomer, although the TDI originally present in the product was predominantly the 2,4-isomer.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 9 (1999), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 9 (1999), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract A simple test chamber method to quantify adsorption and desorption of organic compounds on material surfaces is described. Important environmental parameters such as temperature, relative humidity and air velocity were varied and controlled independently around typical indoor values. Experiments were performed with α-pinene and toluene in concentrations of 160-300 μg/m3. The measurements show adsorption on and desorption from wool carpet, nylon carpet, polyvinyl chloride (PVC) floor coverings, cotton curtain material and the empty chamber. The ranking of the materials, with respect to their sorption capacity, is as mentioned above. The adsorption of α-pinene was higher than the adsorption of toluene for all the materials. Air velocity was not found to influence the sorption of α-pinene and toluene on wool carpet, tested with air velocities at 0, 10 and 20 cm/s. The experiments were carried out during both the adsorption and the desorption phase. The uncertainty of the experiments was lowest during the desorption phase. Based on the results obtained, it can be recommended that sorption experiments should be performed as desorption phase experiments. A one-sink model, based on the Langmuir adsorption isotherm, appears adequate to describe the results.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 9 (1999), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract Walk through questionnaires may be feasible tools to obtain data on the indoor environment in community studies. However, limited information is available regarding the reproducibility of the data obtained through these questionnaires. In this pilot study, two construction engineering students inspected ten dwellings twice by means of a standardized walk through questionnaire. The two engineering students inspected the dwellings independent of each other within two months. Time between the two visits varied between 14 and 40 days. The variables presented were based on information from the residents and inspection. The continuous variables recorded included number of rooms in the dwellings, room volume, length of filled shelves and textile area. The inter- and intra-observed variabilities were poorer for number of rooms and shelf factor than for the other variables. For the 3 of the 9 categorical variables based on inspection, the inter-observer comparison showed complete agreement with a kappa statistics of 1.0, these variables being condition of the window frames and construction of outside walls and roof. One of the categorical variables showed a kappa statistics of 〈0.5, these variables being presence of basement and presence of condensation at windows. This study indicates a wide variation in observer variability between various items of a walk through questionnaire. Clear definitions of all the parts of the questionnaire are needed, as well as thorough training of observers.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 9 (1999), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract Data of chemical emissions from flooring materials have been collected and investigated in a database known as METS. The emission tests are performed using the Field and Laboratory Emission Cell (FLEC). The emission rates of total volatile organic compounds (TVOC) in the boiling point range of hexane to octa-decane varies from around 4,000 μg/(m2· h) to less than 10 μg/ (m2· h). Results obtained 1994/95 are presented and compared with the results obtained in 1992 for similar materials. The tests are performed 4 weeks and 26 weeks after the manufacturing of the material. The emission rates of TVOC decrease on the average approximately 60% from 4 to 26 weeks. The differences and trends in emission rates of individual chemicals and their use are discussed. For many VOCs emission rates decrease rapidly and become near to or below 2 μg/(m2· h) (the detection limit) after 26 weeks. For a small number of individual compounds the emission rate decrease little over 26 weeks. A small number of chemicals are singled out for particular interest in a health and comfort evaluation based on the emission results.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...