ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (11)
  • plasma polymerization  (7)
  • Anisotropy  (4)
  • Springer  (11)
  • American Geophysical Union (AGU)
  • Annual Reviews
  • Wiley
  • 2000-2004  (4)
  • 1980-1984  (7)
  • 1935-1939
  • Technology  (11)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Plasma chemistry and plasma processing 3 (1983), S. 139-161 
    ISSN: 1572-8986
    Keywords: RF plasma ; plasma polymerization ; gas chromatrography ; experimental
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Technology
    Notes: Abstract The plasma polymerization of ethane was studied in a flow reactor of rectangular cross section. The plasma was sustained between parallel-plate electrodes by an RF generator operating at 13.56 MHz. The composition of the gas leaving the reactor was analyzed by gas chromatography. Polymer deposition rates were measured as a function of axial position in the reactor, using a quartz-crystal microbalance. The effluent gas is composed primarily of unreacted C2H6 and H2. Significant concentrations of CH4, C2H4, C2H2, and C3H8, and small amounts of C3H6, i-C5H12, and n-C5H12, are also observed. The distribution of these products is a strong function of the discharge power and of the gas pressure and residence time in the plasma. These experimental variables also affect both the rate of polymer deposition and the shape of the deposition profile along the reactor axis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Plasma chemistry and plasma processing 3 (1983), S. 163-192 
    ISSN: 1572-8986
    Keywords: RF plasma ; plasma polymerization ; modeling ; theoretical
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Technology
    Notes: Abstract A theoretical model has been developed to describe the deposition of polymer occurring in a capacitatively coupled, low-pressure, RF discharge sustained in ethane. The reaction mechanism chosen for this model assumes that polymer formation is controlled by the formation of free radicals in the plasma and the subsequent reaction of these species at the surface of the electrodes used to sustain the plasma. Convective and diffusive transport is taken to occur in the direction parallel to the electrodes. Diffusive transport perpendicular to the electrodes is considered to be rapid, and hence the gradients in this direction are taken to be negligible. Both the composition of the gas leaving the plasma reactor and the axial profile of polymer deposition rate within the reactor, observed experimentally, are predicted accurately by the model. Results obtained from the model have also been used to estimate the kinetic chain length and degree of unsaturation in the polymer. Both predictions are found to be in reasonable agreement with experimental observations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Plasma chemistry and plasma processing 4 (1984), S. 119-127 
    ISSN: 1572-8986
    Keywords: X-ray resist ; vacuum lithography ; plasma polymerization ; plasma etching
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Technology
    Notes: Abstract An X-ray imaged pattern on a plasma-polymerized film was successfully developed by H2 plasma etching. Plasma-polymerized MMA and 6FBMA were formed by using an inductively coupled argon flow type reactor. An X-ray imaged pattern on the film was attained through a knife-cut window of a gold plate. The X-ray was generated from a Cu target at 20 kV and main wavelength 1.54 Å. The pattern development was performed using a tubular type reactor with parallel plate electrodes. The quality of plasma-polymerized resists in an X-ray lithography was evaluated by comparing it with the conventional polymer in the dry and wet process, and the minimum dose rate for a visible pattern fabrication was measured to be 4.1 J/cm2 for both resists in H2 plasma etching development.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1572-8978
    Keywords: dielectric barrier discharges ; corona discharges ; atmospheric pressure plasma deposition ; plasma polymerization ; surface functionalization ; functional groups
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Technology
    Notes: Abstract Dielectric barrier discharge (DBD)-based plasma deposition at atmospheric pressure, using glycidyl methacrylate (GMA, methacrylic acid-[2,3-epoxy-propyl ester]) as a prototype precursor was investigated in order to evaluate the applicability of dielectric barrier discharges to obtain plasma polymers with a high degree of structural retention of the starting precursor. Using pulsed excitation of the discharge, up to about 90% of the epoxy groups of GMA can be retained in plasma polymers obtainableat deposition rates in the order of 3–5nm/s. Preliminary investigations of the mechanism of film formation under pulsed plasma conditions indicate that the reaction of intact monomer molecules withsurface radicals generated during the pulses play a prominent role.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Plasmas and polymers 5 (2000), S. 235-253 
    ISSN: 1572-8978
    Keywords: ESR ; plasma polymerization ; free radical ; thin films ; trimethylsilane ; methane ; PE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Technology
    Notes: Abstract Electron Spin Resonance (ESR) was used to study, at the molecular level, the plasma polymerization of trimethylsilane (TMS) and methane. Direct ESR analysis of the plasma coated Al substrate required the use of a novel ESR technique. TMS plasma deposit on Al showed a single broad resonance line near g = 2.003. The signal was stable in vacuum and decayed on exposure to air, with a significant fraction persisting for days. Results show that this signal arises from silicon dangling bonds. Identical TMS signals were observed from films prepared by the DC cathodic or the AF glow discharge method but their decay rates were different. In contrast, the deposition of methane produced two distinct types of carbon-based signals depending upon the method of deposition. TMS or CH4 films deposited by the DC cathodic method showed slow signals decay and high refractive indices value. While the use of Al as the substrate showed plasma-coating radicals, only substrate radicals were observed when PE was used as the substrate. The nature of radicals formed depends not only on the deposition method used but also on the substrate type.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1572-8978
    Keywords: Poly(tetrafuoroethylene) ; glycidyl methacrylate ; plasma polymerization ; adhesion ; XPS ; polyimides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Technology
    Notes: Abstract Surface modification of poly(tetrafuoroethylene) (PTFE) film by plasma polymerzation and deposition of glycidyl methacrylate (GMA), in the presence and absence of Ar or O2 plasma pre-activation, was carried out to enhance the adhesion with polyimides (PI) film in the presence of an epoxy adhesive. For deposition carried out at low RF power, a high epoxide concentration was preserved in the plasma-polymerized GMA (pp-GMA) layer on PTFE (pp-GMA-PTFE). However, high adhesion strength of the PI/pp-GMA-PTFE laminate was obtained only in the presence of O2 plasma pre-activation of the PTFE substrates prior to plasma polymerization and deposition of GMA. In the absence of any plasma pre-activation or in the presence of Ar plasma pre-activation, the deposited pp-GMA layer on the PTFE surface could be readily removed by solvent extraction. The adhesion enhancement of the PI/pp-GMA-PTFE laminates in the presence of O2 plasma pre-activation was attributed to the preservation of the epoxide functional groups in the pp-GMA layer, the curing of the GMA chains into the matrix of the epoxy adhesive, and the covalent bonding of the pp-GMA layer on the PTFE surface.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 12 (1984), S. 497-510 
    ISSN: 1573-9686
    Keywords: Passive mechanics ; Active stress ; Active constriction ; Elastic modulus ; Series elastic element ; Anisotropy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract Vascular smooth muscle mechanics have been studied in vitro in cylindrical segments of dog carotid artery, human internal mammary artery, and human saphenous vein. Such cylindrical preparations maintain normal vessel geometry and also permit correlation of mechanical phenomena with transmural pressure. These studies show that the vascular muscle in cylindrical arteries develops a maximum active stress of 1.1×105 N/m2 for the whole wall, or 2.2–3.7×105 N/m2 for the volume of the wall occupied by vascular muscle. These values are similar to those reported for strip studies of vascular muscle and various preparations of skeletal muscle, but are two to five times that reported for cardiac papillary muscle preparations. In cylindrical preparations of arteries, maximum isometric active stress occurs at 150 mm Hg, whereas that in veins occurs at less than 15 mm Hg. Quick release experiments of cylindrical segments of vessels avoid the compliance of inactive tissue trapped beneath ligatures in strip studies. Quick release experiments in cylindrical segments of dog carotid artery reveal that at maximum isometric stress, the series elastic component (SEC) is extended 8–11%. Experiments employing temperature variations and degradative enzymes show that the SEC is located largely in elastin, with a lesser portion located in the contractile apparatus. At short-and long-muscle lengths, the active muscle develops decreased active stress and that developed at long lengths persists at all muscle lengths, even after shortening. This has been termed “attenuation” and appears to contribute to the static length-stress and pressure-diameter hysteresis exhibited by vessels. Excitation of vascular muscle in vessel segments held at constant pressure discloses that isobaric contraction decreases artery diameter a maximum of approximately 25%. This occurs at a dimension corresponding to approximately 100 mm Hg in the relaxed vessel. Isometrically and isobarically contracted vessels tend to fall along the same pressure-diameter coordinates, indicating equivalence of both modes of contraction. Distention of contracted vessels indicates that active vascular muscle markedly resists distention up to 150–250 mm Hg; at higher pressures the contracted vessel exhibits decreased stiffness as the contracted muscle yields. The vascular muscle, therefore, has a biphasic effect on circumferential elastic modulus relative to that of the relaxed vessel. Although controversial, evaluation of the effects of the active muscle on wall elastic modulus probably is most meaningful when the modulus is examined as a function of stress, or as a function of strain, where strain is computed with respect to a single initial dimension for both the relaxed and contracted vessel.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 11 (1983), S. 208-261 
    ISSN: 1573-9686
    Keywords: Anisotropy ; Cell-to-cell coupling ; Continuous cable theory ; Discontinuities of axial resistivity ; Discontinuous propagation ; Hodgkin-Huxley equations ; Numerical analysis ; Propagation models ; Propagation of depolarization ; Safety factor of propagation ; Velocity,V max
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract The propagation of excitation in cardiac muscle has generally been treated as though it occurred in a continuous structure. However, new evidence indicates that propagation in cardiac muscle often displays a discontinuous nature. In this paper, we consider the hypothesis that this previously unrecognized type of propagation is caused by recurrent discontinuities of effective axial resistivity which affect the membrane currents. The major implication is that the combination of discontinuities of axial resistivity at several size scales can produce most currently known cardiac conduction disturbances previously thought to require spatial nonuniformities of the membrane properties. At present there is no appropriate model or simulation for propagation in anisotropic cardiac muscle. However, the recent quantitative description of the fast sodium current in voltage-clamped cardiac muscle membrane makes it possible, for the first time, to apply experimentally based quantitative membrane models to propagation in cardiac muscle. The major task now is to account for the functional role of the structural complexities of cardiac muscle. The importance of such a model is that it would establish how the membrane ionic currents and the complexities of cell and tissue structure interact to determine propagation in both normal and abnormal cardiac muscle.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 28 (2000), S. 244-252 
    ISSN: 1573-9686
    Keywords: Anisotropy ; Cardiac ; Computer simulation ; Defibrillation ; Fiber curvature ; Fiber rotation ; Finite element method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract This theoretical study was provoked by and designed to interpret, complement and extend the implications of recent experimental observations by Wikswo and Lin (PACE, 21:940, 1998) on the epicardial surface of rabbit hearts. Using a macroscopic bidomain representation of the cardiac structure and the finite element method, we model the response of the heart to uniform electric fields applied under different angles. To overcome intra- and interspecies differences in the geometric and structural characteristics of the cardiac muscle, the analysis is conducted for an idealized ellipsoidal heart. Although idealized, this heart model incorporates important structural features, i.e., fiber curvature, transmural fiber rotation, and unequal anisotropy for the intra- and extracellular domains. This study shows that regions of maximum polarization of opposite sign may develop along an axis, significantly deviating from the axis of the applied electric field. The polarization evoked inside the ventricular wall seems to be a major contributor to this phenomenon. Nonperiodic structural inhomogeneities on multicellular level (endocardial “trabeculation” in our model) result in local unaligned polarization dipoles weakening the magnitude of the global polarization dipole and reducing its deviation from the axis of stimulation. Our results might be helpful in improving current understanding of defibrillation mechanisms. © 2000 Biomedical Engineering Society. PAC00: 8719Nn, 8719Hh, 8750Rr
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Plasma chemistry and plasma processing 3 (1983), S. 235-248 
    ISSN: 1572-8986
    Keywords: Microwave plasma ; plasma polymerization ; silicon tetrachloride ; experimental
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Technology
    Notes: Abstract Mass spectrometry has been used to analyze microwave-induced plasmas of silicon tetrachloride diluted in mixtures of hydrogen and argon. The effects of process parameters such as pressure in the reactor, power input, and the composition of the gas mixture were investigated. Sampling by a quadrupole mass-spectrometer along the gas stream showed that the reactions were initiated upstream where the reactants enter the plasma. It was found that the input power had an optimal value for the decomposition rate of SiCl4; above that optimum, recombination occurred downstream. Upstream the concentrations of SiCl4 decrease with increasing pressure in the range 1–10 torr, independent of the input power. The effect of admixing argon to the reaction mixture is discussed, and the results obtained are correlated to experimental results reported in previous works concerning silicon deposition from SiCl4 on a grounded substrate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 11 (1983), S. 191-206 
    ISSN: 1573-9686
    Keywords: Electrocardiogram ; Bidomain model ; Heart muscle ; Magnetocardiogram ; Anisotropy ; Model study
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract Cardiac muscle is considered to consist of an intracellular domain and an exracellular or interstitial domain. Current passes from one domain to the other through the cell membrane. Electric potentials in interstitial space are shown to be associated with current sources proportional to the spatial gradient of the cellular transmembrane action potential, φ m . Hence, given the distribution of φ m throughout the myocardium, one can calculate the surface electrocardiogram and extracorporeal magnetocardiogram. The problem is considerably complicated when anisotropy is considered. If interstitial space is approximately isotropic, however, the sources are still proportional to ∇φ m . It is shown that the effects of intracellular anisotropy on the surface electrocardiogram may be relatively small. The inverse problem is discussed briefly, with consideration of the relationship of the magnetocardiogram to the electrocardiogram. Finally, it is shown that if the heart can be considered to be bounded by a closed surface, then the value of φ m on this surface is uniquely related to the surface electrocardiogram to within a constant, provided there are no internal discontinuities. Such discontinuities, however, would be expected to occur in cases of ischemia and necrosis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...