ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous  (3)
  • 04. Solid Earth::04.06. Seismology::04.06.05. Historical seismology  (1)
  • Ca2+ uptake
  • Earthquake ground motions
  • Springer Netherlands  (2)
  • Annual Reviews  (1)
  • Blackwell Publishing Ltd
  • 2005-2009  (4)
  • 1980-1984
Collection
Years
  • 2005-2009  (4)
  • 1980-1984
Year
  • 1
    Publication Date: 2017-04-04
    Description: The H/V-noise technique is now widely used to estimate site effect parameters (fundamental frequency and sometimes the associated soil amplification), and many surveys using this technique have provided convincing results. However, a general agreement on a methodology for data acquisition, data processing and result interpretation has yet to be found. H/V measurements from ambient noise recordings imply both reliability of the results and rapidity of data collection. It is therefore important to understand which experimental conditions (1) influence data quality and reliability, and (2) can help speeding up the recording process. Within the framework of the SESAME European project, a specific task was defined to investigate the reliability of the H/V spectral ratio technique in assessing the site effects. The aim of WP02, one specific Work Package of the SESAME project, is to study the effects of experimental conditions on both stability and reproducibility of H/V results. This study has been conducted in a purely experimental way, by testing the possible influence of various experimental conditions on H/V results both on the frequency peak value and on its amplitude. WP02 results help setting up the experimental conditions under which ambient noise recordings have to be performed in order to provide reproducible, reliable and meaningful H/V results. In this paper we present the results of the WP02 SESAME project concerning the evaluation of the influence of experimental conditions of ambient noise recording on H/V results.
    Description: Published
    Description: 33-74
    Description: 4.1. Metodologie sismologiche per l'ingegneria sismica
    Description: JCR Journal
    Description: reserved
    Keywords: Microtremor ; Site effects ; Field conditions ; Measurements ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous ; 04. Solid Earth::04.06. Seismology::04.06.09. Waves and wave analysis ; 04. Solid Earth::04.06. Seismology::04.06.10. Instruments and techniques
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2017-04-04
    Description: Most of the ancient town of Tindari (NE, Sicily) was settled on a plateau the most surficial layer of which was made of unconsolidated material. Ongoing excavations at the archaeological site at Tindari uncovered a large portion of the decumanus which suffered deformations preliminarily assigned to coseismic effects. An analysis of the local dynamic response through the simulation of strong seismic shaking to the bedrock and modelling of spectral ratios of the bedrock-soft soil was carried out to verify the susceptibility of superficial terrains of the promontory to coseismic deformations. To perform this simulation the finite element method (FEM) was used. Four accelerometric recordings of three earthquakes of medium-high magnitude, recorded on rocky sites, were chosen to simulate the seismic shaking, using a constitutive law for the materials composing the promontory layers both of linear-elastic type and of elastoplastic type. The analysis of the linear-elastic field allowed the definition of the frequencies for which the spectral ratios of the accelerations recorded the highest amplifications; in particular the frequency range 31.5–37.2 Hz can be combined with deformation of the paved floor of the decumanus. The analysis in the elastoplastic field highlighted the zones of promontory more susceptible to suffer plasticization process. The results show that the topmost layer of the decumanus is the most susceptible to suffer plasticization. Therefore, the performed analysis lends greater support to the hypothesis that the deformations were produced by seismic shaking.
    Description: Published
    Description: 213-222
    Description: 3.10. Sismologia storica e archeosismologia
    Description: JCR Journal
    Description: reserved
    Keywords: Fourier analysis ; Elasticity and anelasticity ; Earthquake ground motions ; Site effects ; Computational seismology ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous ; 04. Solid Earth::04.06. Seismology::04.06.05. Historical seismology
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2017-04-04
    Description: For an optimal analysis of the H/V curve, it appears necessary to check the instrument signal to noise ratio in the studied frequency band, to ensure that the signal from the ground noise is well above the internal noise. We assess the reliability and accuracy of various digitizers, sensors and/or digitizer-sensor couples. Although this study is of general interest for any kind of seismological study, we emphasize the influence of equipment on H/V analysis results. To display the impact of the instrumental part on the H/V behavior, some series of tests have been carried out following a step-by-step procedure: first, the digitizers have been tested in the lab (sensitivity, internal noise...), then the three components sensors, still in the lab, and finally the usual user digitizers-sensors couple in lab and outdoors. In general, the digitizer characteristics, verified during this test, correspond well to the manufacturer specifications, however, depending on the digitizer, the quality of the digitized waveform can be very good to very poor, with variation from a channel to another channel (gain, time difference etc.). It appears very clearly that digitizers need a warming up time before the recording to avoid problems in the low-frequency range. Regarding the sensors, we recommend strongly to avoid the use of “classical” accelerometers (i.e., usual force balance technology). The majority of tested seismometers (broadband and short period, even 4.5 Hz) can be used without problems from 0.4 to 25 Hz. In all cases, the instrumentation should be checked first to verify that it works well for the defined study aim, but also to define its limit of use (frequency, sensitivity...).
    Description: Published
    Description: 3-31
    Description: 4.1. Metodologie sismologiche per l'ingegneria sismica
    Description: JCR Journal
    Description: reserved
    Keywords: H/V technique ; Instrumentation ; Microtremors ; Site effects ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous ; 04. Solid Earth::04.06. Seismology::04.06.10. Instruments and techniques
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2022-05-25
    Description: First published online as a Review in Advance on October 24, 2005. (Some corrections may occur before final publication online and in print)
    Description: Author Posting. © Annual Reviews, 2005. This article is posted here by permission of Annual Reviews for personal use, not for redistribution. The definitive version was published in Annual Review of Physiology 68 (2006): 22.1-22.29, doi:10.1146/annurev.physiol.68.040104.105418.
    Description: Superfast muscles of vertebrates power sound production. The fastest, the swimbladder muscle of toadfish, generates mechanical power at frequencies in excess of 200 Hz. To operate at these frequencies, the speed of relaxation has had to increase approximately 50-fold. This increase is accomplished by modifications of three kinetic traits: (a) a fast calcium transient due to extremely high concentration of sarcoplasmic reticulum (SR)-Ca2+ pumps and parvalbumin, (b) fast off-rate of Ca2+ from troponin C due to an alteration in troponin, and (c) fast cross-bridge detachment rate constant (g, 50 times faster than that in rabbit fast-twitch muscle) due to an alteration in myosin. Although these three modifications permit swimbladder muscle to generate mechanical work at high frequencies (where locomotor muscles cannot), it comes with a cost: The high g causes a large reduction in attached force-generating cross-bridges, making the swimbladder incapable of powering low-frequency locomotory movements. Hence the locomotory and sound-producing muscles have mutually exclusive designs.
    Description: This work was made possible by support from NIH grants AR38404 and AR46125 as well as the University of Pennsylvania Research Foundation.
    Keywords: Parvalbumin ; Ca2+ release ; Ca2+ uptake ; Cross-bridges ; Adaptation ; Sound production ; Whitman Center
    Repository Name: Woods Hole Open Access Server
    Type: Article
    Format: 567086 bytes
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...