ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 03. Hydrosphere::03.04. Chemical and biological::03.04.06. Hydrothermal systems
  • AIMNet project
  • Copernicus  (2)
  • AGU  (1)
  • Public Library of Science (PLoS)
  • 2010-2014  (3)
  • 1980-1984
  • 1925-1929
Collection
Years
Year
  • 1
    Publication Date: 2017-04-04
    Description: Etna volcano, Italy, hosts one of the major groundwater systems of the island of Sicily. Waters circulate within highly permeable fractured, mainly hawaiitic, volcanic rocks. Aquifers are limited downwards by the underlying impermeable sedimentary terrains. Thickness of the volcanic rocks generally does not exceed some 300 m, preventing the waters to reach great depths. This is faced by short travel times (years to tens of years) and low thermalisation of the Etnean groundwaters. Measured temperatures are, in fact, generally lower than 25 °C. But the huge annual meteoric recharge (about 0.97 kmˆ3) with a high actual infiltration coefficient (0.75) implies a great underground circulation. During their travel from the summit area to the periphery of the volcano, waters acquire magmatic heat together with volcanic gases and solutes through water-rock interaction processes. In the last 20 years the Etnean aquifers has been extensively studied. Their waters were analysed for dissolved major, minor and trace element, O, H, C, S, B, Sr and He isotopes, and dissolved gas composition. These data have been published in several articles. Here, after a summary of the obtained results, the estimation of the magmatic heat flux through the aquifer will be discussed. To calculate heat uptake during subsurface circulation, for each sampling point (spring, well or drainage gallery) the following data have been considered: flow rate, water temperature, and oxygen isotopic composition. The latter was used to calculate the mean recharge altitude through the measured local isotopic lapse rate. Mean recharge temperatures, weighted for rain amount throughout the year, were obtained from the local weather station network. Calculations were made for a representative number of sampling points (216) including all major issues and corresponding to a total water flow of about 0.315 kmˆ3/a, which is 40% of the effective meteoric recharge. Results gave a total energy output of about 140 MW/a the half of which is ascribable to only 13 sampling points. These correspond to the highest flow drainage galleries with fluxes ranging from 50 to 1000 l/s and wells with pumping rates from 70 to 250 l/s. Geographical distribution indicates that, like magmatic gas leakage, heat flow is influenced by structural features of the volcanic edifice. The major heat discharge through groundwater are all tightly connected either to the major regional tectonic systems or to the major volcanic rift zones along which the most important flank eruptions take place. But rift zones are much more important for heat upraise due to the frequent dikes injection than for gas escape because generally when dikes have been emplaced the structure is no more permeable to gases because it becomes sealed by the cooling magma.
    Description: Published
    Description: Vienna, Austria
    Description: 1.2. TTC - Sorveglianza geochimica delle aree vulcaniche attive
    Description: open
    Keywords: groundwaters ; volcanic surveillance ; water chemistry ; dissolved gases ; 03. Hydrosphere::03.02. Hydrology::03.02.03. Groundwater processes ; 03. Hydrosphere::03.02. Hydrology::03.02.04. Measurements and monitoring ; 03. Hydrosphere::03.04. Chemical and biological::03.04.03. Chemistry of waters ; 03. Hydrosphere::03.04. Chemical and biological::03.04.05. Gases ; 03. Hydrosphere::03.04. Chemical and biological::03.04.06. Hydrothermal systems
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: Oral presentation
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2017-04-04
    Description: In November 2007 we conducted a water column and seafloor mapping study of the submarine volcanoes of the Aeolian Arc in the southern Tyrrhenian Sea aboard the R/V Urania. On 26 conductivity‐temperature‐depth casts and tows we measured temperature, conductivity, pressure, and light scattering and also collected discrete samples for helium isotopes, methane, and pH. The 3He/4He isotope ratio, an unambiguous indicator of hydrothermal input, showed a clear excess above background at 6 of the 10 submarine volcanoes surveyed. Marsili seamount had the highest anomaly, where the 3He/4He ratio reached a d3He value of 23% at 610 m depth compared with background values of ∼5%. Smaller but distinct d3He anomalies occurred over Palinuro, Enarete, Eolo, Sisifo, and Secca del Capo. Although hydrothermal emissions are known to occur offshore of some Aeolian subaerial volcanoes, and hydrothermal deposits have been sampled throughout the arc, our results are the first to confirm active discharge on Marsili, Enarete, Eolo, Sisifo, and Secca del Capo. Samples collected over Lametini, Filicudi North, Alicudi North, and Alcione had d3He near the regional background values, suggesting either absence of, or very weak, hydrothermal activity on these seamounts. Hydrocasts between the volcanoes revealed a consistent d3He maximum between 11% and 13% at 2000mdepth throughout the SE Tyrrhenian Sea. The volcanoes of the Aeolian arc and the Marsili back arc, all 〈1000 m deep, cannot contribute directly to this maximum. This deep 3He excess may be a remnant of tritium decay or may have been produced by an unknown deep hydrothermal source.
    Description: Published
    Description: B02102
    Description: 1.2. TTC - Sorveglianza geochimica delle aree vulcaniche attive
    Description: JCR Journal
    Description: reserved
    Keywords: hydrothermal systems ; helium ; Tyrrhenian sea ; seamounts ; 03. Hydrosphere::03.04. Chemical and biological::03.04.06. Hydrothermal systems
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2017-04-04
    Description: During the 2007-2008 antarctic campaign, the Italian PNRA installed a Low Power Magnetometer within the framework of the AIMNet (Antarctic International Magnetometer Network) project, proposed and coordinated by BAS. The magnetometer is situated at Talos Dome, around 300 km geographically North-West from Mario Zucchelli Station (MZS), and approximately at the same geomagnetic latitude as MZS. In this work we present a preliminary analysis of the geomagnetic field 1-min data, and a comparison with simultaneous data from different Antarctic stations.
    Description: Published
    Description: Vienna, Austria
    Description: 1.6. Osservazioni di geomagnetismo
    Description: open
    Keywords: daily variation ; AIMNet project ; Antarctica ; 04. Solid Earth::04.05. Geomagnetism::04.05.02. Geomagnetic field variations and reversals
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: Poster session
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...