ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Books
  • Other Sources  (2,065)
  • Spacecraft Design, Testing and Performance  (1,150)
  • Instrumentation and Photography  (915)
  • 2015-2019  (1,000)
  • 1995-1999  (1,062)
  • 1940-1944  (3)
Collection
  • Books
  • Other Sources  (2,065)
Source
Years
Year
  • 1
    Publication Date: 2011-10-14
    Description: The first International Symposium on Strain Gauge Balances was sponsored under the auspices of the NASA Langley Research Center (LaRC), Hampton, Virginia. Held at the LaRC Reid Conference Center, the Symposium provided an open international forum for presentation, discussion, and exchange of technical information among wind tunnel test technique specialists and strain gauge balance designers. The Symposium also served to initiate organized professional activities among the participating and relevant international technical communities. The program included a panel discussion, technical paper sessions, tours of local facilities, and vendor exhibits. Over 130 delegates were in attendance from 15 countries. A steering committee was formed to plan a second international balance symposium tentatively scheduled to be hosted in the United Kingdom in 1998 or 1999. The Balance Symposium was followed bv the half-day, Workshop on Angle of Attack and Model Deformation on the afternoon of October 25. The thrust of the Workshop was to assess the state of the art in angle of attack (AoA) and model deformation measurement techniques and to discuss future developments.
    Keywords: Instrumentation and Photography
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-10-14
    Description: Overcoat protection schemes for thin film devices have typically focused on inhibiting the growth of native oxides formed on the sensor surface, rather than on improving the passivating nature of these native oxides. Here, thin sputtered Cr overcoats and heat treatments in varying oxygen partial pressures enhanced the passivating nature of native Cr203 films formed on PdCr thin film strain gages. Results of strain tests using sensors protected using this approach are presented and the implications are discussed. PdCr gages with sputtered Cr overcoats withstood 12,000 dynamic strain cycles of 1100 micro-epsilon during 100 hours of testing at a temperature of 1000 C in air. Gage factors of 1.3 with drift rates as low as 0.1 Omega/hr were achieved for devices having a nominal resistance of approximately 100 Omega's. TCR's ranging from +550 ppm/C to +798 ppm/C were realized depending on the overcoat and thermal history. Possible mechanisms for an anomaly in the electrical characteristics of these films at 800 C and improvements in stability due to the use of overcoats are presented.
    Keywords: Instrumentation and Photography
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-10-14
    Description: Instrumentation systems have always been essential components of world class wind tunnels and laboratories. Langley continues to be on the forefront of the development of advanced systems for aerospace applications. This paper will describe recent advances in selected measurement systems which have had significant impact on aerospace testing. To fully understand the aerodynamics and aerothermodynamics influencing aerospace vehicles, highly accurate and repeatable measurements need to be made of critical phenomena. However, to maintain leadership in a highly competitive world market, productivity enhancement and the development of new capabilities must also be addressed aggressively. The accomplishment of these sometimes conflicting requirements has been the challenge of advanced measurement developers. However, several new technologies have recently matured to the point where they have enabled the achievement of these goals. One of the critical areas where advanced measurement systems are required is flow field velocity measurements. These measurements are required to correctly characterize the flowfield under study, to quantify the aerodynamic performance of test articles and to assess the effect of aerodynamic vehicles on their environment. Advanced measurement systems are also making great strides in obtaining planar measurements of other important thermodynamic quantities, including species concentration, temperature, pressure and the speed of sound. Langley has been on the forefront of applying these technologies to practical wind tunnel environments. New capabilities in Projection Moire Interferometry and Acoustics Array Measurement systems have extended our capabilities into the model deformation, vibration and noise measurement arenas. An overview of the status of these techniques and recent applications in practical environments will be presented in this paper.
    Keywords: Instrumentation and Photography
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-24
    Description: This paper describes a 12-channel infrared radiometer with the acronym SABER (Sounding of the Atmosphere using Broadband Emission radiometry) that has been selected by NASA to fly on the TIMED (Thermosphere-Ionosphere-Mesosphere Energetics and Dynamics) mission.
    Keywords: Instrumentation and Photography
    Type: ; 130-132
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-24
    Description: The traditional lidar over the last thirty years has typically been a big pulse low repetition rate system. Pulse energies are in the 0.1 to 1.0 J range and repetition rates from 0.1 to 10 Hz. While such systems have proven to be good research tools, they have a number of limitations that prevent them from moving beyond lidar research to operational, application oriented instruments. These problems include a lack of eye safety, very low efficiency, poor reliability, lack of ruggedness and high development and operating costs. Recent advances in solid state laser, detectors and data systems have enabled the development of a new generation of lidar technology that meets the need for routine, application oriented instruments. In this paper the new approaches to operational lidar systems will be discussed. Micro pulse lidar (MPL) systems are currently in use, and their technology is highlighted. The basis and current development of continuous wave (CW) lidar and potential of other technical approaches is presented.
    Keywords: Instrumentation and Photography
    Type: ; 26-28
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2004-12-03
    Description: The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) measures spectral radiance in the solar reflected spectrum from 400 to 2500 nm. Spectra are measured through 224 spectral channels with nominally 10-nm sampling and 10-nm full width at half maximum (FWHM). From a NASA ER-2 aircraft flying at 20,000 m altitude, these spectra are acquired as images with an 11-km width by up to 800-km length. The spatial sampling is 17 m, and the instantaneous field of view (IFOV) 20 m. The objective of AVIRIS is to acquire calibrated spectra that are used to derive properties of the Earth's land, water, and atmosphere for scientific research and environmental applications. To achieve this objective, the AVIRIS spectra must be calibrated. The AVIRIS sensor is calibrated in the laboratory before and after each flight season, however, the spectra acquired by AVIRIS for science investigators are acquired in the Q-bay of the ER-2 at 20 km altitude. The objective of the AVIRIS inflight calibration experiment is to validate the calibration of AVIRIS spectral images in the low pressure, low temperature operating environment of the ER-2. Inflight calibration experiments have been orchestrated for AVIRIS in every year of flight operations.
    Keywords: Instrumentation and Photography
    Type: Summaries of the Seventh JPL Airborne Earth Science Workshop January 12-16, 1998; Volume 1; 193-203; JPL-Publ-97-21-Vol-1
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2004-12-03
    Description: The AVIRIS On-Board Calibrator (OBC) provides essential data for refining the calibration of each AVIRIS data run. Annual improvement to the AVIRIS sensor and laboratory calibration accuracy has resulted in increasingly high demands on the stability of the OBC. Since the 1995 flight season, the OBC could track the stability of the spectrometer alignment to the 2% level, a significant improvement over previous years. The major contributor to this 2% stability was the conversion from a constant-current bulb power supply to an intensity-based active feedback power supply. Given the high sensor signal-to-noise ratio, improving the OBC to track 1% or 0.5% changes was highly desirable. Achieving stability better than 2% required an examination of the mechanisms affecting stability.
    Keywords: Instrumentation and Photography
    Type: Summaries of the Seventh JPL Airborne Earth Science Workshop January 12-16, 1998; Volume 1; 105-110; JPL-Publ-97-21-Vol-1
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2004-12-03
    Description: The Hydrodynamic Focusing Bioreactor (HDFB) technology is designed to provide a flow field with nearly uniform shear force throughout the vessel, which can provide the desired low shear force spatial environment to suspend three-dimensional cell aggregates while providing optimum mass transfer. The reactor vessel consists of a dome-shaped cell culture vessel, a viscous spinner, an access port, and a rotating base. The domed vessel face has a radius of R(o). and rotates at 0mega(o) rpm, while the internal viscous spinner has a radius of R(i) and rotates at 0mega(i) rpm. The culture vessel is completely filled with cell culture medium into which three-dimensional cellular structures are introduced. The HDFB domed vessel and spinner were driven by two independent step motors,
    Keywords: Instrumentation and Photography
    Type: KC-135 and Other Microgravity Simulations; 62-64; NASA/CR-1999-208922
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2004-12-03
    Description: Coherent Doppler lidar is a promising technique for the global measurements of winds using a space-based platform. Doppler lidar produces estimates of the radial component of the velocity vector averaged over the resolution volume of the measurement. Profiles of the horizontal vector winds are produced by scanning the lidar beam or stepping the lidar beam through a sequence of different angles (step-stare). The first design for space-based measurements proposed a conical scan which requires a high power laser to produce acceptable signal levels for every laser pulse. Performance is improved by fixing the laser beam and accumulating the signal from many lidar pulses for each range-gate. This also improves the spatial averaging of the wind estimates and reduces the threshold signal energy required for a good estimate. Coherent Doppler lidar performance for space-based operation is determined using computer simulations and including the wind variability over the measurement volume as well as the variations of the atmospheric aerosol backscatter.
    Keywords: Instrumentation and Photography
    Type: Tenth Biennial Coherent Laser Radar Technology and Applications Conference; 298-301; NASA/CP-1999-209758
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2004-12-03
    Description: A useful measure of sensor performance is the transceiver system efficiency n (sub sys). Which consists of the antenna efficiency n (sub a) and optical and electronic losses. Typically, the lidar equation and the antenna efficiency are defined in terms of the telescope aperture area. However, during the assembly of a coherent transceiver, it is important to measure the system efficiency before the installation of the beamexpanding telescope (i.e., the untruncated-beam system efficiency). Therefore, to accommodate both truncated and untruncated beam efficiency measurements, we define the lidar equation and the antenna efficiency in terms of the beam area rather than the commonly used aperture area referenced definition. With a well-designed Gaussian-beam lidar, aperture area referenced system efficiencies of 15 to 20 % (23-31% relative to the beam area) are readily achievable. In this paper we compare the differences between these efficiency definitions. We then describe techniques by which high efficiency can be achieved, followed by a discussion several novel auto alignment techniques developed to maintain high efficiency.
    Keywords: Instrumentation and Photography
    Type: Tenth Biennial Coherent Laser Radar Technology and Applications Conference; 247-250; NASA/CP-1999-209758
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...