ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (11)
  • hyperthermia  (11)
  • Wiley-Blackwell  (11)
  • Annual Reviews
  • Oxford University Press
  • Periodicals Archive Online (PAO)
  • 2020-2024
  • 1980-1984  (11)
  • Physics  (11)
Collection
  • Articles  (11)
Publisher
  • Wiley-Blackwell  (11)
  • Annual Reviews
  • Oxford University Press
  • Periodicals Archive Online (PAO)
Years
Year
Topic
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 3 (1982), S. 73-80 
    ISSN: 0197-8462
    Keywords: Born approximation ; Eikonal approximation ; hyperthermia ; inverse problem ; scattering ; imaging ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: There are several reasons for investigating the inverse scattering problem in medical image processing. A typical case, that of ultrasonic fields, is considered. Assuming that a plane wave illuminates a weakly inhomogeneous two-dimensional object, the fundamental equation is derived for the scattered waves in integral as well as in differential forms. It is shown that the scattered waves observed on a circle surrounding the object is sufficient to specify the structure of the object. This information is summarized in a single term, which is a function of the wavenumber as well as the angles of incidence and observation. A successive approximation is applied to reconstruct the image of the object from this function. Since no analytic solution is available, several methods of approximations are proposed, and examples of computations are shown for the case of a cylindrical object.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 3 (1982), S. 253-274 
    ISSN: 0197-8462
    Keywords: radiofrequency ; nearfield ; hyperthermia ; dosimetry ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A homogeneous, lossy circular cylinder is used as a simple model of a biological object in which interior heating is produced by the absorption of electromagnetic waves. For this model, we determined the optimum frequency, polarization, orientation and shape of applicators. Analytical and numerical results are given for both electric and magnetic line sources, with three different polarizations relative to the cylinder. Coupling efficiencies and contour plots are presented for a range of parameters. One particularly interesting result is the production of maximum energy deposition at the center of a cylinder of muscle tissue when exposed in the 100-MHz frequency range by the use of four applicators surrounding the cylinder.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 115-122 
    ISSN: 0197-8462
    Keywords: microwave biological effects ; hyperthermia ; B lymphocytes ; capping ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Normal mouse B lymphocytes were tested for the ability to cap plasma membrane antigenantibody complexes following exposure to 2.45-GHz continuous wave (CW) microwaves at power densities up to 100 mW/cm2 (45 W/kg specific absorption rate), at 37, 41, and 42.5 °C. After a 30-minute treatment, the irradiated cells and the nonirradiated controls were tested for capping by the direct immunofluorescence technique. First, the cells were incubated for nine minutes at 37 °C with fluorescein isothiocyanate-conjugated goat antimouse immunoglobulin. After fixing and washing, the percentage of capped cells was determined under a fluorescence microscope. The results show that for the nonirradiated controls, capping is reduced from 90% at 37 °C, to 52% 41 °C. to less than 5% for cells that were pretreated at 42.5 °C. There was no significant difference between the microwave-treated cells and the controls when both were maintained at the same temperature. In another experiment, there was no significant difference in the percentage of capping between controls and cells that were exposed to microwave radiation during capping, when the temperature in both preparations was kept at 38.5 °C. The results demonstrate that B-lymphocyte capping is sensitive to temperature in the range that is proposed for use in tumor therapy.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 157-165 
    ISSN: 0197-8462
    Keywords: amplitude-modulated RF fields ; hyperthermia ; B lymphocytes ; capping ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: B lymphocytes collected from normal ICR Swiss mouse spleens were exposed in vitro in a Crawford cell to 147-MHz radiofrequency (RF) radiation, amplitude modulated by a 9-, 16-, or 60-Hz sine wave. The power densities ranged between 0.11 and 48 mW/cm2. The irradiated samples and the controls were maintained at 37 °C or 42 °C, with temperature variations less than 0.1 °C. Immediately after a 30-minute exposure, the distribution of antigen-antibody (Ag—Ab) complexes on the cell surface was evaluated at 37 °C by immunofluorescence. Under normal conditions (37 °C, no RF), Ag—Ab complexes are regrouped into a polar cap by an energy-dependent process. Our results demonstrate that the irradiated cells and the nonirradiated controls capped Ag—Ab complexes equally well after exposure at 37 °C. Capping was equally inhibited at 42 °C in both the controls and irradiated cells. No statistically significant differences in capping were observed between the RF-exposed and control samples at any of the modulation frequencies and power densities employed as long as both preparations were maintained at the same temperature.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 249-255 
    ISSN: 0197-8462
    Keywords: radiofrequency radiation ; 27.12 MHz ; hyperthermia ; teratology ; rat ; embryo ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Five groups of pregnant Sprague-Dawley rats were either sham exposed or were irradiated in a 27.12-MHz radiofrequency (RF) field at 55 A/m and 300 V/m on gestation day 9. The absorbed power (approximately 11 W/kg) caused a relatively rapid increase in the rat's colonic temperature. Rats in group I were sham irradiated for 2.5 h at 0 A/m, 0 V/m. In group II RF irradiation was terminated after the rat's colonic temperature reached 41.0 °C. In group III the 41.0- °C temperature was maintained an additional 15 min by varying the field strength. At both temperatures the teratogenic and embryotoxic effects of the RF-induced hyperthermia increased as the exposure duration increased, but the increase was especially noticeable at 42.0 °C. The results indicate that the teratogenic and embryotoxic effects of RF-induced hyperthermia are related to both the temperature of the dam during exposure and the length of time the dam's temperature remains elevated.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 63-70 
    ISSN: 0197-8462
    Keywords: hyperthermia ; microwaves ; brain ; ATP ; CP ; energy metabolism ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The effects of hyperthermia, alone and in conjunction with microwave exposure, on brain energetics were studied in anesthetized male Sprague-Dawley rats. The effect of temperature on adenosine triphosphate concentration [ATP] and creatine phosphate concentration [CP] was determined in the brains of rats that were maintained at 35.6, 37.0, 39.0, and 41.0°C. At 37, 39, and 41°C brain [ATP] and [CP] were down 6.0, 10.8, and 29.2%, and 19.6, 28.7, and 44%, respectively, from the 35.6°C control concentrations. Exposure of the brain to 591-MHz radiation at 13.8 mW/cm2 for 0.5, 1.0, 3.0, and 5.0 min caused further decreases (below those observed for 30°C hyperthermia only) of 16.0, 29.8, 22.5, and 12.3% in brain [ATP], and of 15.6, 25.1, 21.4, and 25.9% in brain [CP] after 0.5, 1.0, 3.0, and 5.0 min, respectively. Recording of brain reduced nicotinamide adenine dinucleotide (NADH) fluorescence before, during, and after microwave exposure showed an increase in NADH fluorescence during microwave exposure that returned to preexposure levels within 1 min postexposure. Continuous recording of brain temperatures during microwave exposures showed that brain temperature varied between -0.1 and +0.05°C. Since the microwave exposures did not induce tissue hyperthermia, it is concluded that direct microwave interaction at the subcellular level is responsible for the observed decrease in [ATP] and [CP].
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 55-62 
    ISSN: 0197-8462
    Keywords: 2880-MHz microwaves ; submaxillary salivary gland ; Na+ ; K+ ; Ca2+ ; flame photometry ; hyperthermia ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Na+, K+, and Ca2+ concentrations in the blood serum and submaxillary salivary gland (SSG) were investigated in adult, male rats exposed to 2880-MHz microwaves modulated with 1.5-μs pulses at a pulse repetition rate of 1000 Hz or in a hyperthermal environment. Rats were exposed, one at a time, for 30 min to microwaves producing a specific absorption rate (SAR) of: 4.2, 6.3,6.8,8.4, 10.8, or 12.6 W/kg, or were sham exposed under similar environmental conditions. In a second series, one group of rats was exposed singly for 15, 30, or 60 min to microwaves producing an SAR of 9.5 W/kg and other rats were exposed for similar periods at 40 °C; and 10 rats were sham exposed. Flame photometric analysis indicated that the thresholds of microwave radiation required to induce a change in Na+, K+, and Ca2+ concentrations in the salivary glands are 6.8, 6.8, and 6.3 W/kg, respectively. The directions of Na+, K+, and Ca2+ ion shifts in exposed rats' salivary glands are similar, whether affected by microwaves or hyperthermia. Greater changes in Na+ and K+ concentrations in SSG of rats exposed to microwaves for 15 and 30 min were found than in those exposed at 40 °C. On the other hand, exposure to hyperthermia at 40 °C or to microwaves for 1 h caused Na+ concentration to be increased by 68.7 and 59.5% and K+ concentration to be decreased by 29.6 and 21.7%, respectively.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 3 (1982), S. 237-245 
    ISSN: 0197-8462
    Keywords: liquid crystal thermometry ; microwave heating ; cells ; hyperthermia ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A nonperturbing technique of thin-layer liquid crystal thermometry was developed to quantitate heating of Chinese hamster ovary cells and the bacterium Serratia marcescens when exposed to 2450-MHz microwave fields at 0.2-0.5 W/cm2. Cells suspended in culture medium were injected into 5-cm glass microcapillary tubes coated on the inside with a thin layer of liquid crystal. The tubes were sealed and placed parallel to the electric field in a watertight waveguide exposure chamber where they were heated by circulating temperature-controlled water. Even at high circulation rates, liquid crystal color changes indicated local microwave capillary tube heating of 0.1-0.25 °C. Precision of measurement was 0.02 °C. Observations during microwave heating were significantly different from observations without microwaves at the 1% level, and heating increased as circulating water flow was reduced from 300 ml/s to 100 ml/s. The results of a cell survival assay following hyperthermal treatment were in good agreement with expectations based on the observations of microwave heating using liquid crystals.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 3 (1982), S. 275-283 
    ISSN: 0197-8462
    Keywords: microwaves ; 2.45 GHz ; heat stress ; hyperthermia ; in vivo ; mouse ; preimplantation embryos ; development ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The development of preimplantation embryos after exposure to microwave radiation was studied. Female CD-1 mice were induced to superovulate, mated, and exposed to 2.45-GHz microwave or sham radiation for 3 h at power densities of 9 mW/cm2 and 19 mW/cm2 on either day 2 or 3 of pregnancy (plug day was considered day 1). Another group of mice was exposed to heat stress by placing the dams in an environmental room at an ambient temperature of 38 °C and relative humidity at 62% for 3 h on day 2 of pregnancy. All groups were euthanized on day 4 of pregnancy and embryos were recovered by flushing excised uterine horns. Embryos were examined for abnormalities and classified by the developmental stages. They were then treated with hypotonic solution and dissociated for counting blastomeres. Heat stress caused stunted development of embryos, but no remarkable effect of microwave radiation could be found on the development of preimplantation embryos.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 3 (1982), S. 363-370 
    ISSN: 0197-8462
    Keywords: microwave ; hyperthermia ; hamster ; PARA-7 tumor ; computer ; 2.45 GHz ; temperature distribution ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A minicomputer-based system was designed to control the microwave (2.45-GHz) power to four local hyperthermia applicators. Errors in temperature measurement, due to electromagnetic field interactions with small thermocouple probes, are minimized by sampling the temperature only when the microwave power is off. The programmable controller can regulate the temperature in tumors in 0.1 °C increments from 30 to 60 °C. This technique reduces temperature differences throughout the tumor at steady state to less than 0.4 °C and prevents skin burns.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 3 (1982), S. 91-103 
    ISSN: 0197-8462
    Keywords: electromagnetic fields ; microwaves ; physiology ; neuroendocrine ; physiologic integration ; hyperthermia ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Electromagnetic fields have been demonstrated to elicit thermoregulatory responses, neuroen-docrine, neurochemical modulations, and behavioral reactions. These physiologic regulatory processes are exquisitely tuned, interrelated functions that constitute sensitive indicators of organismic responses to radiofrequency energy absorption (the radio frequency portion of the electromagnetic spectrum includes as one part microwaves). Assessment of the integration and correlation of these functions relative to the thermal inputs and homeokinetic reactions of the individual subjected to radiofrequency energy should permit differentiation between potential hazards that might compromise the individual's ability to maintain normal physiologic function and effects that are compensated by physiologic redundancy.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...