ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • XAS  (3)
  • X‐ray free‐electron lasers  (3)
  • International Union of Crystallography  (6)
  • MDPI Publishing
  • Nature Publishing Group
  • 2020-2024  (2)
  • 2020-2022  (4)
  • 1970-1974
Collection
Publisher
Language
Years
  • 2020-2024  (2)
  • 2020-2022  (4)
  • 1970-1974
Year
  • 1
    Publication Date: 2023-01-25
    Description: A newly designed setup to perform steady‐state X‐ray excited optical luminescence (XEOL) spectroscopy and simultaneous XEOL and X‐ray absorption spectroscopy characterization at beamline P65 of PETRA III is described. The XEOL setup is equipped with a He‐flow cryostat and state‐of‐the‐art optical detection system, which covers a wide wavelength range of 300–1700 nm with a high spectral resolution of 0.4 nm. To demonstrate the setup functioning, low‐temperature XEOL studies on polycrystalline CuInSe2 thin film, single‐crystalline GaN thin film and single‐crystalline ZnO bulk semiconductor samples are performed.
    Description: X‐ray excited optical luminescence (XEOL) spectroscopy is increasingly important to understand the interplay between the optical properties, structure and chemical composition, providing insights into the mechanism of radiative recombination for a wide range of materials. This study demonstrates a newly implemented setup to perform steady‐state XEOL and simultaneous XEOL and XAFS characterizations at beamline P65 of PETRA III.
    Keywords: ddc:550.2 ; XEOL ; XAS ; CuInSe2 ; ZnO ; GaN
    Language: English
    Type: doc-type:article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2023-12-12
    Description: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉Studying electron‐ and X‐ray‐induced electron cascades in solids is essential for various research areas at free‐electron laser facilities, such as X‐ray imaging, crystallography, pulse diagnostics or X‐ray‐induced damage. To better understand the fundamental factors that define the duration and spatial size of such cascades, this work investigates the electron propagation in ten solids relevant for the applications of X‐ray lasers: Au, B〈sub〉4〈/sub〉C, diamond, Ni, polystyrene, Ru, Si, SiC, Si〈sub〉3〈/sub〉N〈sub〉4〈/sub〉 and W. Using classical Monte Carlo simulation in the atomic approximation, we study the dependence of the cascade size on the incident electron or photon energy and on the target parameters. The results show that an electron‐induced cascade is systematically larger than a photon‐induced cascade. Moreover, in contrast with the common assumption, the maximal cascade size does not necessarily coincide with the electron range. It was found that the cascade size can be controlled by careful selection of the photon energy for a particular material. Photon energy, just above an ionization potential, can essentially split the absorbed energy between two electrons (photo‐ and Auger), reducing their initial energy and thus shrinking the cascade size. This analysis suggests a way of tailoring the electron cascades for applications requiring either small cascades with a high density of excited electrons or large‐spread cascades with lower electron densities.〈/p〉
    Description: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉Studying electron‐ and X‐ray‐induced electron cascades in solids is essential for various research areas at free‐electron laser facilities, such as X‐ray imaging, crystallography, pulse diagnostics or X‐ray‐induced damage. To better understand the fundamental factors that define the duration and spatial size of such cascades, this work investigates the electron propagation in ten solids relevant for the applications of X‐ray lasers. Using classical Monte Carlo simulation in the atomic approximation, the dependence of the cascade size on the incident electron or photon energy and on the target parameters is studied.〈boxed-text position="anchor" content-type="graphic" xml:lang="en"〉〈graphic position="anchor" id="jats-graphic-1" xlink:href="urn:x-wiley:16005775:jsy2gb5123:jsy2gb5123-fig-0001"〉 〈/graphic〉〈/boxed-text〉〈/p〉
    Keywords: ddc:548 ; electron cascades ; X‐ray free‐electron lasers ; Monte Carlo ; photon‐induced cascade ; electron transport
    Language: English
    Type: doc-type:article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2021-06-30
    Description: ROBL‐II provides four different experimental stations to investigate actinide and other alpha‐ and beta‐emitting radionuclides at the new EBS storage ring of ESRF within an energy range of 3 to 35 keV. The XAFS station consists of a highly automatized, high sample throughput installation in a glovebox, to measure EXAFS and conventional XANES of samples routinely at temperatures down to 10 K, and with a detection limit in the sub‐p.p.m. range. The XES station with its five bent‐crystal analyzer, Johann‐type setup with Rowland circles of 1.0 and 0.5 m radii provides high‐energy resolution fluorescence detection (HERFD) for XANES, XES, and RIXS measurements, covering both actinide L and M edges together with other elements accessible in the 3 to 20 keV energy range. The six‐circle heavy duty goniometer of XRD‐1 is equipped for both high‐resolution powder diffraction as well as surface‐sensitive CTR and RAXR techniques. Single crystal diffraction, powder diffraction with high temporal resolution, as well as X‐ray tomography experiments can be performed at a Pilatus 2M detector stage (XRD‐2). Elaborate radioprotection features enable a safe and easy exchange of samples between the four different stations to allow the combination of several methods for an unprecedented level of information on radioactive samples for both fundamental and applied actinide and environmental research.
    Description: ROBL‐II at ESRF provides four experimental stations to investigate actinides with X‐ray absorption and emission spectroscopy, and with surface, high‐resolution powder, and single‐crystal X‐ray diffractometry.
    Keywords: 549 ; actinides ; EXAFS ; XANES ; HERFD‐XANES ; XAS ; XES ; RIXS ; XRD ; CTR ; RAXR ; surface diffraction
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2021-06-26
    Description: The high‐precision X‐ray diffraction setup for work with diamond anvil cells (DACs) in interaction chamber 2 (IC2) of the High Energy Density instrument of the European X‐ray Free‐Electron Laser is described. This includes beamline optics, sample positioning and detector systems located in the multipurpose vacuum chamber. Concepts for pump–probe X‐ray diffraction experiments in the DAC are described and their implementation demonstrated during the First User Community Assisted Commissioning experiment. X‐ray heating and diffraction of Bi under pressure, obtained using 20 fs X‐ray pulses at 17.8 keV and 2.2 MHz repetition, is illustrated through splitting of diffraction peaks, and interpreted employing finite element modeling of the sample chamber in the DAC.
    Description: The high‐precision X‐ray diffraction (XRD) setup for work with diamond anvil cells (DACs) in Interaction Chamber 2 of the High Energy Density (HED) instrument of the European X‐ray Free‐Electron Laser is described. image
    Keywords: 548 ; diamond anvil cells ; X‐ray free‐electron lasers ; high‐precision X‐ray diffraction ; finite element modeling
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2021-06-26
    Description: X‐SPEC is a high‐flux spectroscopy beamline at the KIT (Karlsruhe Institute of Technology) Synchrotron for electron and X‐ray spectroscopy featuring a wide photon energy range. The beamline is equipped with a permanent magnet undulator with two magnetic structures of different period lengths, a focusing variable‐line‐space plane‐grating monochromator, a double‐crystal monochromator and three Kirkpatrick–Baez mirror pairs. By selectively moving these elements in or out of the beam, X‐SPEC is capable of covering an energy range from 70 eV up to 15 keV. The flux of the beamline is maximized by optimizing the magnetic design of the undulator, minimizing the number of optical elements and optimizing their parameters. The beam can be focused into two experimental stations while maintaining the same spot position throughout the entire energy range. The first experimental station is optimized for measuring solid samples under ultra‐high‐vacuum conditions, while the second experimental station allows in situ and operando studies under ambient conditions. Measurement techniques include X‐ray absorption spectroscopy (XAS), extended X‐ray absorption fine structure (EXAFS), photoelectron spectroscopy (PES) and hard X‐ray PES (HAXPES), as well as X‐ray emission spectroscopy (XES) and resonant inelastic X‐ray scattering (RIXS).
    Description: X‐SPEC is a high‐flux undulator beamline for electron and X‐ray spectroscopy with an energy range from 70 eV to 15 keV. It offers X‐ray absorption spectroscopy (XAS), extended X‐ray absorption fine structure (EXAFS), photoelectron spectroscopy (PES) and hard X‐ray PES (HAXPES), as well as X‐ray emission spectroscopy (XES) and resonant inelastic X‐ray scattering (RIXS) for in vacuo, in situ and operando sample environments. image
    Keywords: 548 ; undulator beamline ; soft X‐ray ; tender X‐ray ; hard X‐ray ; in situ ; operando ; HAXPES ; RIXS ; XAS ; XES
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    facet.materialart.
    Unknown
    International Union of Crystallography | 5 Abbey Square, Chester, Cheshire CH1 2HU, England
    Publication Date: 2021-09-29
    Description: The resolution function of a spectrometer based on a strongly bent single crystal (bending radius of 10 cm or less) is evaluated. It is shown that the resolution is controlled by two parameters: (i) the ratio of the lattice spacing of the chosen reflection to the crystal thickness and (ii) a single parameter comprising crystal thickness, its bending radius, distance to a detector, and anisotropic elastic constants of the chosen crystal. The results allow the optimization of the parameters of bent‐crystal spectrometers for the hard X‐ray free‐electron laser sources.
    Description: The resolution function of a bent‐crystal spectrometer for pulses of an X‐ray free‐electron laser is evaluated. Under appropriate conditions, the energy resolution reaches the ratio of the lattice spacing to the crystal thickness. image
    Keywords: 548 ; X‐ray free‐electron lasers ; X‐ray spectroscopy ; bent crystals ; diamond crystal optics ; femtosecond X‐ray diffraction
    Type: map
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...